Comparative evaluation of BacT/ALERT 3D and BACTEC systems for the recovery of pathogens causing bloodstream infections

被引:22
|
作者
Jamal, Wafaa [1 ]
Tamaray, Gigette [1 ]
Pazhoor, Aleyamma [1 ]
Rotimi, V. O. [1 ]
机构
[1] Mubarak Al Kabeer Hosp, Dept Lab Med, Microbiol Unit, Jabriya, Kuwait
关键词
BacT/ALERT blood culture system; BACTEC 9240 blood culture system; bacteraemia;
D O I
10.1159/000092186
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: To compare BacT/ALERT (BTA) and BACTEC 9240 (BAC), two continuously monitoring automated blood culture systems, for the recovery of bloodstream pathogens and standard media available for these systems. Materials and Methods: Blood samples from 100 adults and 50 paediatric patients suspected of having bloodstream infections were inoculated at the bedside into non-vented BTA and BAC standard blood culture bottles and incubated in their respective instruments. The time to growth detection (TD) was recorded for each bottle that became positive. A quantitative assay was also carried out with 5 standard bloodstream pathogens to assess TD of each pathogen as well as the quantity of organisms recovered. Results: A total of 23 isolates representing true infections were recovered by both BTA and BAC bottles, indicating a blood culture positivity rate of 15.3%, 18 (78.3%) by BTA bottles and 13 (56.5%) by BAC. Proteus mirabilis, Pseudomonas aeruginosa and Clostridium perfringens were recovered only by the BTA system. The average TDs were 19.0 and 24.6 h for BTA and BAC, respectively. Analysis of the quantitative growth of known pathogens in both systems was more or less the same for Staphylococcus aureus, Escherichia coli and P. aeruginosa but slightly different for Haemophilus influenzae and Streptococcus pneumoniae. The anaerobic bottle of the BTA did not support the growth of H. influenzae below an inoculum of 10(10) CFU/ml whereas the BAC did so at a lower inoculum of 10(8) CFU/ml. TD for S. pneumoniae in the BTA was about half of that in the BAC. Conclusions: The BTA system appears to be more efficient in detecting common bloodstream pathogens as a higher inoculum is needed for the BAC system to detect the same organism. Copyright (C) 2006 S. Karger AG, Basel.
引用
收藏
页码:223 / 227
页数:5
相关论文
共 50 条
  • [21] Comparison of MB/BacT ALERT 3D System with radiometric BACTEC system and Lowenstein-Jensen medium for recovery and identification of mycobacteria from clinical specimens: a multicenter study
    Piersimoni, C
    Scarparo, C
    Callegaro, A
    Tosi, CP
    Nista, D
    Bornigia, S
    Scagnelli, M
    Rigon, A
    Ruggiero, G
    Goglio, A
    JOURNAL OF CLINICAL MICROBIOLOGY, 2001, 39 (02) : 651 - 657
  • [22] Evaluation of BACTEC™ FX and BacT/Alert™ Automated Blood Culture Systems for Detection of Clinically Relevant Bacterial and Yeast Species
    Absar, Muhammad
    Alshahrani, Ibraheem
    Nashmy, Fahd
    Salami, Mosa
    Hadadi, Ali
    AlMarzooq, Aous
    AlAsiri, Alhussain
    AlRashidi, Abdulaziz
    AlFaifi, Mohammed
    ADVANCEMENTS IN LIFE SCIENCES, 2024, 11 (03): : 648 - 654
  • [23] Evaluation of BacT/ALERT 3D signature in a blood bank setting, One-year anniversary
    Fayed, R
    Taylor, C
    Linauts, S
    TRANSFUSION, 2004, 44 (09) : 52A - 52A
  • [24] A项BacT/ALERT 3D与B项BACTEC FX的血培养系统比对及性能评价
    向成玉
    实用医院临床杂志, 2017, 14 (01) : 97 - 99
  • [25] Evaluation of the 3D BacT/ALERT automated culture system for the detection of microbial contamination of platelet concentrates
    McDonald, CP
    Rogers, A
    Cox, M
    Smith, R
    Roy, A
    Robbins, S
    Hartley, S
    Barbara, JAJ
    Rothenberg, S
    Stutzman, L
    Widders, G
    TRANSFUSION MEDICINE, 2002, 12 (05) : 303 - 309
  • [26] BacT/ALERT VIRTUO和BacT/ALERT 3D两种血培养系统的性能评价
    马艳
    周春妹
    黄声雷
    沈佳瑾
    史庆丰
    潘柏申
    王蓓丽
    郭玮
    中华医院感染学杂志, 2023, 33 (11) : 1622 - 1626
  • [27] Comparison of 'time to detection' values between BacT/ALERT VIRTUO and BacT/ALERT 3D instruments for clinical blood culture samples
    Congestri, Francesco
    Pedna, Maria Federica
    Fantini, Michela
    Samuelli, Michela
    Schiavone, Pasqua
    Torri, Arianna
    Bertini, Stefania
    Sambri, Vittorio
    INTERNATIONAL JOURNAL OF INFECTIOUS DISEASES, 2017, 62 : 1 - 5
  • [28] Evaluation of the BacT/ALERT and BACTEC 9240 automated blood culture systems for growth time of Brucella species in a Turkish tertiary hospital
    Baysallar, Mehmet
    Aydogan, Hakan
    Kilic, Abdullah
    Kucukkaraaslan, Ayten
    Senses, Zeynep
    Doganci, Levent
    MEDICAL SCIENCE MONITOR, 2006, 12 (07): : BR235 - BR238
  • [29] Bactec FX和Bact/Alert 3D两种血培养系统对菌血症的检出性能分析
    王颖
    史利宁
    范明
    黄梅
    王卫萍
    奚海燕
    胡毓安
    贾煊
    邵海枫
    临床检验杂志, 2012, 30 (01) : 13 - 15
  • [30] ASSESSMENT OF 3 AUTOMATED BLOOD CULTURING SYSTEMS BIO-ARGOS, BACT/ALERT AND BACTEC NR-860
    AUBERT, G
    VAUTRIN, AC
    MICHEL, VP
    FRESARD, A
    DORCHE, G
    PATHOLOGIE BIOLOGIE, 1993, 41 (04): : 434 - 440