Comparative evaluation of BacT/ALERT 3D and BACTEC systems for the recovery of pathogens causing bloodstream infections

被引:22
|
作者
Jamal, Wafaa [1 ]
Tamaray, Gigette [1 ]
Pazhoor, Aleyamma [1 ]
Rotimi, V. O. [1 ]
机构
[1] Mubarak Al Kabeer Hosp, Dept Lab Med, Microbiol Unit, Jabriya, Kuwait
关键词
BacT/ALERT blood culture system; BACTEC 9240 blood culture system; bacteraemia;
D O I
10.1159/000092186
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: To compare BacT/ALERT (BTA) and BACTEC 9240 (BAC), two continuously monitoring automated blood culture systems, for the recovery of bloodstream pathogens and standard media available for these systems. Materials and Methods: Blood samples from 100 adults and 50 paediatric patients suspected of having bloodstream infections were inoculated at the bedside into non-vented BTA and BAC standard blood culture bottles and incubated in their respective instruments. The time to growth detection (TD) was recorded for each bottle that became positive. A quantitative assay was also carried out with 5 standard bloodstream pathogens to assess TD of each pathogen as well as the quantity of organisms recovered. Results: A total of 23 isolates representing true infections were recovered by both BTA and BAC bottles, indicating a blood culture positivity rate of 15.3%, 18 (78.3%) by BTA bottles and 13 (56.5%) by BAC. Proteus mirabilis, Pseudomonas aeruginosa and Clostridium perfringens were recovered only by the BTA system. The average TDs were 19.0 and 24.6 h for BTA and BAC, respectively. Analysis of the quantitative growth of known pathogens in both systems was more or less the same for Staphylococcus aureus, Escherichia coli and P. aeruginosa but slightly different for Haemophilus influenzae and Streptococcus pneumoniae. The anaerobic bottle of the BTA did not support the growth of H. influenzae below an inoculum of 10(10) CFU/ml whereas the BAC did so at a lower inoculum of 10(8) CFU/ml. TD for S. pneumoniae in the BTA was about half of that in the BAC. Conclusions: The BTA system appears to be more efficient in detecting common bloodstream pathogens as a higher inoculum is needed for the BAC system to detect the same organism. Copyright (C) 2006 S. Karger AG, Basel.
引用
收藏
页码:223 / 227
页数:5
相关论文
共 50 条
  • [31] BacT/Alert 3D血培养仪临床应用评价
    谢艳斌
    临床医药文献电子杂志, 2016, 3 (51) : 10187+10190 - 10187
  • [32] The turn-around-times (TATs) of BacT/ALERT 3D™ and VersaTREK™
    Deocaris, C.
    Daguimol, B.
    Pascual, H.
    Dela Rosa, R.
    Abendanio, E. M.
    Manganip, L.
    De Mesa-Rodriguez, R.
    INTERNATIONAL JOURNAL OF INFECTIOUS DISEASES, 2011, 15 : S20 - S20
  • [33] Characteristics of False-Positive Alarms in the BacT/Alert 3D System
    Amano, Misato
    Matsumoto, Mami
    Sano, Shigeru
    Oyama, Mayumi
    Nagumo, Hideto
    Watanabe-Okochi, Naoko
    Tsuno, Nelson H.
    Nakajima, Kazunori
    Muroi, Kazuo
    MICROBIOLOGY SPECTRUM, 2022, 10 (03):
  • [34] BacT/Alert 3D血培养仪临床应用评价
    朱成宾
    窦露
    夏永祥
    中华医院感染学杂志, 2008, (08) : 1198 - 1200
  • [35] Multicenter Comparison of the BacT/ALERT Virtuo and BacT/ALERT 3D Instruments for the Rapid Detection of Bacterial Contaminants in Leukocyte Reduced Apheresis Platelets
    Jacobs, Michael
    Good, Caryn E.
    Allen, Jennifer
    McDonald, Carl
    TRANSFUSION, 2017, 57 : 195A - 195A
  • [36] Evaluation of a novel kit for use with the BacT/ALERT 3D system for drug susceptibility testing of Mycobacterium tuberculosis
    Werngren, J
    Klintz, L
    Hoffner, SE
    JOURNAL OF CLINICAL MICROBIOLOGY, 2006, 44 (06) : 2130 - 2132
  • [37] CONTROLLED CLINICAL-EVALUATION OF BACTEC PLUS AEROBIC/F AND BACT/ALERT AEROBIC FAN BOTTLES FOR DETECTION OF BLOOD-STREAM INFECTIONS
    POHLMAN, JK
    KIRKLEY, BA
    EASLEY, KA
    BASILLE, BA
    WASHINGTON, JA
    JOURNAL OF CLINICAL MICROBIOLOGY, 1995, 33 (11) : 2856 - 2858
  • [38] Bact/Alert 3D全自动血培养仪使用评价
    陈日荣
    李惠冰
    实用医技杂志, 2005, (12) : 1605 - 1606
  • [39] Bact/Alert 3D系统与常用检测方法的比较
    周辉
    张治国
    杜春英
    吴进凤
    临床肺科杂志, 2009, 14 (07) : 902 - 903
  • [40] BacT/Alert 3D血培养仪阳性报警时间分析
    刘莹
    中国现代药物应用, 2016, 10 (05) : 274 - 275