Evaluation of BACTEC™ FX and BacT/Alert™ Automated Blood Culture Systems for Detection of Clinically Relevant Bacterial and Yeast Species

被引:0
|
作者
Absar, Muhammad [1 ]
Alshahrani, Ibraheem [1 ]
Nashmy, Fahd [1 ]
Salami, Mosa [1 ]
Hadadi, Ali [1 ]
AlMarzooq, Aous [1 ]
AlAsiri, Alhussain [1 ]
AlRashidi, Abdulaziz [1 ]
AlFaifi, Mohammed [1 ]
机构
[1] King Abdulaziz Hosp Natl Guard, Dept Pathol & Lab Med, Alahsa, Saudi Arabia
来源
ADVANCEMENTS IN LIFE SCIENCES | 2024年 / 11卷 / 03期
关键词
Blood Culture System; Recovery Rate; Time to detection; Blood stream infection; BTA3D; Bactec FX; SEVERE SEPSIS; SEPTIC SHOCK; PERFORMANCE; TRENDS; BACTEREMIA; MORTALITY; BURDEN; IMPACT; TIME;
D O I
暂无
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
Background: Bloodstream infections (BSI) are a significant health concern, necessitating effective diagnostic tools. This study evaluates the performance of the BD Bactec FX system in comparison to the established BacT/Alert system, examining mean time till detection (TTD) across various blood culture bottles. Methods: The study involves 148 blood culture bottles, inoculated with representative bacterial ATCC strains (n= 15) and 04 yeast isolates. Parallel testing is conducted by seeding 10-30 colony-forming units (CFU) in duplicate in both BD Bactec FX and BacT/Alert systems. TTD is assessed across aerobic, anaerobic, and pediatric bottles for diverse microbial species. Results: All 148 bottles tested in parallel show positive signals in both systems. BD Bactec FX demonstrates significantly shorter TTD for adult-seeded cultures in aerobic and anaerobic bottles compared to BacT/Alert Similarly, pediatric bottles with BD Bactec FX exhibit a shorter TTD compared to BacT/Alert. The statistical significance of TTD, 95% confidence intervals (CI), and p-values is evident for Bactec FX aerobic, anaerobic, and pediatric bottles across tested organisms. Notable examples of faster TTD include; Bacteroides ovatus (16.6h by Bactec FX vs. 70.5h by Bact/Alert 3D), Stenotrophomonas maltophilia (33.7h vs. 72.5h), and Streptococcus pyogenes (8.1h vs. 11.9h). Conclusions: In conclusion, the study's findings demonstrate that BD Bactec FX surpasses BacT/Alert in prompt microbial detection, showcasing potential for early identification of bacteremia and fungemia. Faster TTD implies the potential to initiate timely antimicrobial treatment, thereby reducing patient morbidity and mortality. However, exceptions in certain microbial species highlight the need for comprehensive clinical validation to establish the broad applicability of these findings.
引用
收藏
页码:648 / 654
页数:7
相关论文
共 50 条
  • [1] Time-to-detection of bacteria and yeast with the BACTEC FX versus BacT/Alert Virtuo blood culture systems
    Somily, Ali Mohammed
    Babay, Hanan Ahmed Habib
    Torchyan, Armen Albert
    Sayyed, Samina B.
    Absar, Muhammed
    Al-Aqeel, Rima
    Binkhamis, Khalifa
    ANNALS OF SAUDI MEDICINE, 2018, 38 (03) : 194 - 199
  • [2] Comparative evaluation of BACTEC FX, BacT/ALERT 3D, and BacT/ALERT VIRTUO-automated blood culture systems using simulated blood cultures
    Li, Zhengkang
    Liu, Suling
    Chen, Huimin
    Zhang, Xinqiang
    Ling, Yong
    Zhang, Ni
    Hou, Tieying
    ACTA CLINICA BELGICA, 2022, 77 (01) : 71 - 78
  • [3] In vitro Evaluation of BACT/ALERT® VIRTUO®, BACT/ALERT 3D®, and BACTEC™ FX Automated Blood Culture Systems for Detection of Microbial Pathogens Using Simulated Human Blood Samples
    Menchinelli, Giulia
    Liotti, Flora Marzia
    Fiori, Barbara
    De Angelis, Giulia
    D'Inzeo, Tiziana
    Giordano, Lilian
    Posteraro, Brunella
    Sabatucci, Michela
    Sanguinetti, Maurizio
    Spanu, Teresa
    FRONTIERS IN MICROBIOLOGY, 2019, 10
  • [4] Comparative evaluation of BacT/ALERT VIRTUO and BACTEC FX400 blood culture systems for the detection of bloodstream infections
    Qin, Yurong
    Liao, Yiwen
    Zhou, Jingfang
    Liu, Weijiang
    Chen, Huimin
    Chen, Xiaoli
    Wang, Weisha
    Zhang, Ni
    Zhao, Yunhu
    Wang, Liang
    Gu, Bing
    Liu, Suling
    MICROBIOLOGY SPECTRUM, 2025, 13 (01)
  • [5] Comparison of the BACTEC 9240 and BacT/Alert blood culture systems for detection of bacterial contamination in platelet concentrates
    Riedel, Stefan
    Siwek, Gregory
    Beekmann, Susan E.
    Richter, Sandra S.
    Raife, Thomas
    Doern, Gary V.
    JOURNAL OF CLINICAL MICROBIOLOGY, 2006, 44 (06) : 2262 - 2264
  • [6] Evaluation of the BacT/ALERT and BACTEC 9240 automated blood culture systems for growth time of Brucella species in a Turkish tertiary hospital
    Baysallar, Mehmet
    Aydogan, Hakan
    Kilic, Abdullah
    Kucukkaraaslan, Ayten
    Senses, Zeynep
    Doganci, Levent
    MEDICAL SCIENCE MONITOR, 2006, 12 (07): : BR235 - BR238
  • [7] In vitro Evaluation of BACT/ALERT® VIRTUO®, BACT/ALERT 3D®, and BACTEC™ FX Automated Blood Culture Systems for Detection of Microbial Pathogens Using Simulated Human Blood Samples (vol 10, 221, 2019)
    Menchinelli, Giulia
    Liotti, Flora Marzia
    Fiori, Barbara
    De Angelis, Giulia
    D'Inzeo, Tiziana
    Giordano, Liliana
    Posteraro, Brunella
    Sabbatucci, Michela
    Sanguinetti, Maurizio
    Spanu, Teresa
    FRONTIERS IN MICROBIOLOGY, 2019, 10
  • [8] Epidemiology of bloodstream infections and time to detection of positive blood cultures: An evaluation of the automated BacT/Alert and BACTEC 9240 systems
    Endimiani, A
    Tamborini, A
    Luzzaro, F
    Lombardi, G
    Toniolo, A
    MICROBIOLOGICA, 2002, 25 (01): : 9 - 16
  • [9] Direct comparison of the BACTEC 9240 and BacT/ALERT 3D automated blood culture systems for Candida growth detection
    Horvath, LL
    George, BJ
    Murray, CK
    Harrison, LS
    Hospenthal, DR
    JOURNAL OF CLINICAL MICROBIOLOGY, 2004, 42 (01) : 115 - 118
  • [10] Comparison of the Bactec 9240 and BacT/Alert Blood Culture Systems for Evaluation of Placental Cord Blood for Transfusion in Neonates
    Riedel, Stefan
    Junkins, Alan
    Stamper, Paul D.
    Cress, Gretchen
    Widness, John A.
    Doern, Gary V.
    JOURNAL OF CLINICAL MICROBIOLOGY, 2009, 47 (06) : 1645 - 1649