Marginal and internal fit of three-unit fixed dental prostheses fabricated from translucent multicolored zirconia: Framework versus complete contour design

被引:2
|
作者
Ueda, Kazuhiko [1 ]
Watanabe, Fumihiko [1 ]
Katsuta, Yasuhiro [1 ]
Seto, Munetsugu [1 ]
Ueno, Daisuke [1 ]
Hiroyasu, Kazuhiko [2 ]
Suzuki, Shohei [1 ]
Erdelt, Kurt [3 ]
Gueth, Jan-Frederik [3 ]
机构
[1] Nippon Dent Univ, Sch Life Dent Niigata, Dept Crown & Bridge Prosthodont, Niigata, Japan
[2] Nippon Dent Univ, Oral Implant Care Unit, Niigata Hosp, Niigata, Japan
[3] Ludwig Maximilians Univ Munchen, Univ Hosp, Dept Prosthet Dent, Munich, Germany
来源
JOURNAL OF PROSTHETIC DENTISTRY | 2021年 / 125卷 / 02期
关键词
D O I
10.1016/j.prosdent.2020.08.023
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. Translucent multicolored zirconia materials enable more esthetic complete contour zirconia fixed dental prostheses (FDPs) than conventional zirconia, which exhibits low translucency and high opacity and is monochromatic. However, how the marginal and internal fit of translucent multicolored zirconia FDPs compare with those of traditional frameworks that require veneering is unclear. Purpose. The purpose of this in vitro study was to compare the marginal and internal fit of frameworks and complete contour 3-unit FDPs fabricated from translucent multicolored zirconia. Material and methods. Frameworks with a thickness of 0.5 mm and complete contour FDPs with a thickness of 0.8 to 1.5 mm were manufactured by using a workflow similar to one from a zirconia master model (mandibular left second premolar-mandibular left second molar). Two polyvinyl siloxane replicas were made for each specimen to measure the marginal and internal fit. Measurement locations were mesial, lingual, buccal, and distal for each abutment. In these locations, the marginal opening (MO), chamfer area (CA), axial wall (AW), and occlusal area (OC) were measured. The data were analyzed with 2-way ANOVA and the Bonferroni post hoc test (alpha=.05). Results. Frameworks showed significantly better mean +/- standard deviation fit values than complete contour 3-unit FDPs at measurement areas MO (frameworks: 112 +/- 22 mu m, complete contour FDPs: 144 +/- 37 mu m) (P=.013), CA (frameworks: 89 +/- 12 mu m, complete contour FDPs: 110 +/- 22 mu m) (P=.006), and OC (frameworks: 182 +/- 36 mu m, complete contour FDPs: 244 +/- 64 mu m) (P=.008). At the measurement area AW (frameworks: 47 +/- 7 mu m, complete contour FDPs: 50 +/- 9 mu m of each location, no significant difference was observed between frameworks and complete contour FDPs (P=.361). Conclusions. Design differences in 3-unit FDPs fabricated from translucent multicolored zirconia influenced the marginal and internal fit. Frameworks had smaller marginal fit than complete contour FDPs for translucent multicolored zirconia.
引用
收藏
页码:340.e1 / 340.e6
页数:6
相关论文
共 50 条
  • [41] In vitro study of the fracture resistance of monolithic lithium disilicate, monolithic zirconia, and lithium disilicate pressed on zirconia for three-unit fixed dental prostheses
    Choi, Jae-Won
    Kim, So-Yeun
    Bae, Ji-Hyeon
    Bae, Eun-Bin
    Huh, Jung-Bo
    JOURNAL OF ADVANCED PROSTHODONTICS, 2017, 9 (04): : 244 - 251
  • [42] Fracture Resistance of Straight and Angulated Zirconia Implant Abutments Supporting Anterior Three-Unit Lithium Disilicate Fixed Dental Prostheses
    Saker, Samah
    El-Shahat, Sameh
    Ghazy, Mohamed
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2016, 31 (06) : 1240 - 1246
  • [43] Five-Year Results of One-Piece Zirconia Oral Implants Supporting Three-Unit Fixed Dental Prostheses
    Kohal, Ralf-Joachim
    Vach, Kirstin
    Butz, Frank
    Patzelt, Sebastian Berthold Maximilian
    Burkhardt, Felix
    CLINICAL ORAL IMPLANTS RESEARCH, 2025,
  • [44] Marginal and internal fit of curved anterior CAD/CAM-milled zirconia fixed dental prostheses: An in-vitro study
    Buechi, Dominik L.
    Ebler, Sabine
    Haemmerle, Christoph H. F.
    Sailer, Irena
    QUINTESSENCE INTERNATIONAL, 2014, 45 (10): : 837 - 846
  • [45] Marginal and internal fit of pre-sintered Co-Cr and zirconia 3-unit fixed dental prostheses as measured using microcomputed tomography
    Daou, Elie E.
    Ounsi, Hani
    Ozcan, Mutlu
    Husain, Nadin Al-Haj
    Salameh, Ziad
    JOURNAL OF PROSTHETIC DENTISTRY, 2018, 120 (03): : 409 - 414
  • [46] One-Piece Zirconia Oral Implants for the Support of Three-Unit Fixed Dental Prostheses: Three-Year Results from a Prospective Case Series
    Kohal, Ralf-Joachim
    Vach, Kirstin
    Butz, Frank
    Spies, Benedikt Christopher
    Patzelt, Sebastian Berthold Maximilian
    Burkhardt, Felix
    JOURNAL OF FUNCTIONAL BIOMATERIALS, 2023, 14 (01)
  • [47] Comparative Evaluation of Load-Bearing Capacity and Fracture Analysis of PEEK and Zirconia Three-Unit Fixed Dental Prostheses: An In Vitro Study
    Jain, Radhika A.
    Gupta, Rekha
    Verma, Mahesh
    Nanda, Aditi
    Gill, Shubhra
    Mehra, Rashmi
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2022, 35 (02) : 225 - 232
  • [48] Marginal and Internal Fit of Cobalt-Chromium Fixed Dental Prostheses Generated from Digital and Conventional Impressions
    Svanborg, Per
    Skjerven, Henrik
    Carlsson, Pablo
    Eliasson, Alf
    Karlsson, Stig
    Ortorp, Anders
    INTERNATIONAL JOURNAL OF DENTISTRY, 2014, 2014
  • [49] Comparison of marginal and internal fit of 3-unit ceramic fixed dental prostheses made with either a conventional or digital impression
    Su, Ting-Shu
    Sun, Jian
    JOURNAL OF PROSTHETIC DENTISTRY, 2016, 116 (03): : 362 - 367
  • [50] Effects of build orientation on adaptation of casting patterns for three-unit partial fixed dental prostheses fabricated by using digital light projection
    Chaiamornsup, Patcharanun
    Iwasaki, Naohiko
    Tsuchida, Yumi
    Takahashi, Hidekazu
    JOURNAL OF PROSTHETIC DENTISTRY, 2022, 128 (05): : 1047 - 1054