Marginal and Internal Fit of Cobalt-Chromium Fixed Dental Prostheses Generated from Digital and Conventional Impressions

被引:43
|
作者
Svanborg, Per [1 ]
Skjerven, Henrik [2 ]
Carlsson, Pablo [1 ]
Eliasson, Alf [3 ,4 ]
Karlsson, Stig [1 ]
Ortorp, Anders [1 ]
机构
[1] Gothenburg Univ, Sahlgrenska Acad, Inst Odontol, Dept Prosthet Dent Dent Mat Sci, Medicinaregatan 12 F,POB 450, S-40530 Gothenburg, Sweden
[2] Univ Oslo, Dept Prosthet Dent, N-0161 Oslo, Norway
[3] Postgrad Dent Educ Ctr, Dept Prosthet Dent, S-70111 Orebro, Sweden
[4] Orebro Univ, Sch Hlth & Med Sci, S-70281 Orebro, Sweden
关键词
D O I
10.1155/2014/534382
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives. Digital impressions are increasingly used and have the potential to avoid the problem of inaccurate impressions. Only a few studies to verify the accuracy of digital impressions have been performed. The purpose of this study was to compare the marginal and internal fit of 3-unit tooth supported fixed dental prostheses (FDPs) fabricated from digital and conventional impressions. Methods. Ten FDPs were produced from digital impressions using the iTero system and 10 FDPs were produced using vinyl polysiloxane (VPS) impression material. A triple-scan protocol and CAD software were used for measuring and calculating discrepancies of the FDPs at 3 standard areas: mean internal discrepancy, absolute marginal gap, and cervical area discrepancy. The Mann-Whitney U test was used for analyzing the results. Results. For conventional and digital impressions, respectively, FDPs had an absolute marginal gap of 147 mu m and 142 mu m, cervical area discrepancy of 69 mu m and 44 mu m, and mean internal discrepancy of 117 mu m and 93 mu m. The differences were statistically significant in the cervical and internal areas (P < 0.001). Significance. The results indicated that the digital impression technique is more exact and can generate 3-unit FDPs with a significantly closer fit compared to the VPS technique.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Internal and marginal fit of cobalt-chromium fixed dental prostheses fabricated with 3 different techniques
    Nesse, Harald
    Ulstein, Dina Mari Akeryik
    Vaage, Malene Myhre
    Oilo, Marit
    JOURNAL OF PROSTHETIC DENTISTRY, 2015, 114 (05): : 686 - 692
  • [2] Digital technique for in vivo assessment of internal and marginal fit of fixed dental prostheses
    Park, Ji-Man
    Hammerle, Christoph H. F.
    Benic, Goran I.
    JOURNAL OF PROSTHETIC DENTISTRY, 2017, 118 (04): : 452 - 454
  • [3] Digital evaluation of marginal and internal fit of single-crown fixed dental prostheses
    Dahl, Bjorn E.
    Dahl, Jon E.
    Ronold, Hans J.
    EUROPEAN JOURNAL OF ORAL SCIENCES, 2018, 126 (06) : 512 - 517
  • [4] Marginal and internal fit of four-unit zirconia fixed dental prostheses based on digital and conventional impression techniques
    Almeida e Silva, Junio S.
    Erdelt, Kurt
    Edelhoff, Daniel
    Araujo, Elito
    Stimmelmayr, Michael
    Cardoso Vieira, Luiz Clovis
    Gueth, Jan-Frederik
    CLINICAL ORAL INVESTIGATIONS, 2014, 18 (02) : 515 - 523
  • [5] Marginal and internal fit of four-unit zirconia fixed dental prostheses based on digital and conventional impression techniques
    Júnio S. Almeida e Silva
    Kurt Erdelt
    Daniel Edelhoff
    Élito Araújo
    Michael Stimmelmayr
    Luiz Clovis Cardoso Vieira
    Jan-Frederik Güth
    Clinical Oral Investigations, 2014, 18 : 515 - 523
  • [6] Evaluation of marginal/internal fit of fixed dental prostheses after digital, conventional, and combination impression techniques: A systematic review
    Sarafidou, Katia
    Chatziparaskeva, Maria
    Chatzikamagiannis, Dimitrios
    Mpotskaris, Vasileios
    Tortopidis, Dimitrios
    Bakopoulou, Athina
    Kokoti, Maria
    EUROPEAN JOURNAL OF ORAL SCIENCES, 2022, 130 (06)
  • [7] Marginal and internal fit of five-unit zirconia-based fixed dental prostheses fabricated with digital scans and conventional impressions: A comparative in vitro study
    Bandiaky, Octave Nadile
    Clouet, Roselyne
    Le Bars, Pierre
    Soueidan, Assem
    Le Guehennec, Laurent
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2023, 32 (09): : 846 - 853
  • [8] Influence of CAD/CAM on the fit accuracy of implant-supported zirconia and cobalt-chromium fixed dental prostheses
    Gonzaga, Danilo
    Morals, Maria Helena S. T.
    das Neves, Flavio D.
    Barbosa, Gustavo A. S.
    JOURNAL OF PROSTHETIC DENTISTRY, 2015, 113 (01): : 22 - 28
  • [9] Comparison of marginal and internal fit of 3-unit ceramic fixed dental prostheses made with either a conventional or digital impression
    Su, Ting-Shu
    Sun, Jian
    JOURNAL OF PROSTHETIC DENTISTRY, 2016, 116 (03): : 362 - 367
  • [10] A Comparison Study of Marginal and Internal Fit Assessment Methods for Fixed Dental Prostheses
    Son, Keunbada
    Lee, Sangbong
    Kang, Seok Hyon
    Park, Jaeseok
    Lee, Kyu-Bok
    Jeon, Mansik
    Yun, Byoung-Ju
    JOURNAL OF CLINICAL MEDICINE, 2019, 8 (06)