Marginal and internal fit of three-unit fixed dental prostheses fabricated from translucent multicolored zirconia: Framework versus complete contour design

被引:2
|
作者
Ueda, Kazuhiko [1 ]
Watanabe, Fumihiko [1 ]
Katsuta, Yasuhiro [1 ]
Seto, Munetsugu [1 ]
Ueno, Daisuke [1 ]
Hiroyasu, Kazuhiko [2 ]
Suzuki, Shohei [1 ]
Erdelt, Kurt [3 ]
Gueth, Jan-Frederik [3 ]
机构
[1] Nippon Dent Univ, Sch Life Dent Niigata, Dept Crown & Bridge Prosthodont, Niigata, Japan
[2] Nippon Dent Univ, Oral Implant Care Unit, Niigata Hosp, Niigata, Japan
[3] Ludwig Maximilians Univ Munchen, Univ Hosp, Dept Prosthet Dent, Munich, Germany
来源
JOURNAL OF PROSTHETIC DENTISTRY | 2021年 / 125卷 / 02期
关键词
D O I
10.1016/j.prosdent.2020.08.023
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. Translucent multicolored zirconia materials enable more esthetic complete contour zirconia fixed dental prostheses (FDPs) than conventional zirconia, which exhibits low translucency and high opacity and is monochromatic. However, how the marginal and internal fit of translucent multicolored zirconia FDPs compare with those of traditional frameworks that require veneering is unclear. Purpose. The purpose of this in vitro study was to compare the marginal and internal fit of frameworks and complete contour 3-unit FDPs fabricated from translucent multicolored zirconia. Material and methods. Frameworks with a thickness of 0.5 mm and complete contour FDPs with a thickness of 0.8 to 1.5 mm were manufactured by using a workflow similar to one from a zirconia master model (mandibular left second premolar-mandibular left second molar). Two polyvinyl siloxane replicas were made for each specimen to measure the marginal and internal fit. Measurement locations were mesial, lingual, buccal, and distal for each abutment. In these locations, the marginal opening (MO), chamfer area (CA), axial wall (AW), and occlusal area (OC) were measured. The data were analyzed with 2-way ANOVA and the Bonferroni post hoc test (alpha=.05). Results. Frameworks showed significantly better mean +/- standard deviation fit values than complete contour 3-unit FDPs at measurement areas MO (frameworks: 112 +/- 22 mu m, complete contour FDPs: 144 +/- 37 mu m) (P=.013), CA (frameworks: 89 +/- 12 mu m, complete contour FDPs: 110 +/- 22 mu m) (P=.006), and OC (frameworks: 182 +/- 36 mu m, complete contour FDPs: 244 +/- 64 mu m) (P=.008). At the measurement area AW (frameworks: 47 +/- 7 mu m, complete contour FDPs: 50 +/- 9 mu m of each location, no significant difference was observed between frameworks and complete contour FDPs (P=.361). Conclusions. Design differences in 3-unit FDPs fabricated from translucent multicolored zirconia influenced the marginal and internal fit. Frameworks had smaller marginal fit than complete contour FDPs for translucent multicolored zirconia.
引用
收藏
页码:340.e1 / 340.e6
页数:6
相关论文
共 50 条
  • [21] Evaluation of Marginal and Internal Fit of Presintered Co-Cr and Zirconia Three-Unit Fixed Dental Prosthesis Compared to Cast Co-Cr
    Daou, Elie E.
    Baba, Nadim Z.
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2020, 29 (09): : 792 - 799
  • [22] The fit of cobalt-chromium three-unit fixed dental prostheses fabricated with four different techniques: A comparative in vitro study
    Ortorp, Anders
    Jonsson, David
    Mouhsen, Alaa
    von Steyern, Per Vult
    DENTAL MATERIALS, 2011, 27 (04) : 356 - 363
  • [23] Evaluation of the fit of zirconia three-unit fixed partial dentures fabricated by different impression techniques
    Moustapha, Ghassan
    Azzam, Khaled
    AlShwaimi, Emad
    Silwadi, Munir
    Ferraris, Marco
    Salameh, Ziad
    JOURNAL OF INVESTIGATIVE AND CLINICAL DENTISTRY, 2019, 10 (03)
  • [24] MARGINAL AND INTERNAL FIT OF PARTIAL-RETAINER CAD/CAM ZIRCONIA FIXED DENTAL PROSTHESES
    Candea, Adrian
    Jivanescu, Anca
    Leretter, Marius
    Rominu, Mihai
    PROCEEDINGS OF THE ROMANIAN ACADEMY SERIES A-MATHEMATICS PHYSICS TECHNICAL SCIENCES INFORMATION SCIENCE, 2017, 18 (04): : 345 - 352
  • [25] The effect of pre-ceramic soldering on marginal and internal fit of 4-unit zirconia frameworks and monolithic zirconia fixed dental prostheses
    Diler Ozkan Irem
    Dilara Seyma Alpkilic
    Sabire Isler Deger
    Odontology, 2024, 112 : 169 - 176
  • [26] Comparison of marginal and internal fit of 5-unit zirconia fixed dental prostheses fabricated with CAD/CAM technology using direct and indirect digital scans
    Uluc, Irem Gokce
    Guncu, Mustafa Baris
    Aktas, Guliz
    Turkyilmaz, Ilser
    JOURNAL OF DENTAL SCIENCES, 2022, 17 (01) : 63 - 69
  • [27] The effect of pre-ceramic soldering on marginal and internal fit of 4-unit zirconia frameworks and monolithic zirconia fixed dental prostheses
    Irem, Diler Ozkan
    Alpkilic, Dilara Seyma
    Deger, Sabire Isler
    ODONTOLOGY, 2024, 112 (01) : 169 - 176
  • [28] Marginal and internal fit of five-unit zirconia-based fixed dental prostheses fabricated with digital scans and conventional impressions: A comparative in vitro study
    Bandiaky, Octave Nadile
    Clouet, Roselyne
    Le Bars, Pierre
    Soueidan, Assem
    Le Guehennec, Laurent
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2023, 32 (09): : 846 - 853
  • [29] Internal and marginal fit of cobalt-chromium fixed dental prostheses fabricated with 3 different techniques
    Nesse, Harald
    Ulstein, Dina Mari Akeryik
    Vaage, Malene Myhre
    Oilo, Marit
    JOURNAL OF PROSTHETIC DENTISTRY, 2015, 114 (05): : 686 - 692
  • [30] Comparison of marginal and internal adaptation of three-unit fixed dental prostheses made using CAD/CAM metal-free materials
    Baran, Melike Cigdem
    Demirci, Fatih
    Tuzlali, Mesut
    EUROPEAN JOURNAL OF ORAL SCIENCES, 2022, 130 (06)