Marginal and internal fit of three-unit fixed dental prostheses fabricated from translucent multicolored zirconia: Framework versus complete contour design

被引:2
|
作者
Ueda, Kazuhiko [1 ]
Watanabe, Fumihiko [1 ]
Katsuta, Yasuhiro [1 ]
Seto, Munetsugu [1 ]
Ueno, Daisuke [1 ]
Hiroyasu, Kazuhiko [2 ]
Suzuki, Shohei [1 ]
Erdelt, Kurt [3 ]
Gueth, Jan-Frederik [3 ]
机构
[1] Nippon Dent Univ, Sch Life Dent Niigata, Dept Crown & Bridge Prosthodont, Niigata, Japan
[2] Nippon Dent Univ, Oral Implant Care Unit, Niigata Hosp, Niigata, Japan
[3] Ludwig Maximilians Univ Munchen, Univ Hosp, Dept Prosthet Dent, Munich, Germany
来源
JOURNAL OF PROSTHETIC DENTISTRY | 2021年 / 125卷 / 02期
关键词
D O I
10.1016/j.prosdent.2020.08.023
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. Translucent multicolored zirconia materials enable more esthetic complete contour zirconia fixed dental prostheses (FDPs) than conventional zirconia, which exhibits low translucency and high opacity and is monochromatic. However, how the marginal and internal fit of translucent multicolored zirconia FDPs compare with those of traditional frameworks that require veneering is unclear. Purpose. The purpose of this in vitro study was to compare the marginal and internal fit of frameworks and complete contour 3-unit FDPs fabricated from translucent multicolored zirconia. Material and methods. Frameworks with a thickness of 0.5 mm and complete contour FDPs with a thickness of 0.8 to 1.5 mm were manufactured by using a workflow similar to one from a zirconia master model (mandibular left second premolar-mandibular left second molar). Two polyvinyl siloxane replicas were made for each specimen to measure the marginal and internal fit. Measurement locations were mesial, lingual, buccal, and distal for each abutment. In these locations, the marginal opening (MO), chamfer area (CA), axial wall (AW), and occlusal area (OC) were measured. The data were analyzed with 2-way ANOVA and the Bonferroni post hoc test (alpha=.05). Results. Frameworks showed significantly better mean +/- standard deviation fit values than complete contour 3-unit FDPs at measurement areas MO (frameworks: 112 +/- 22 mu m, complete contour FDPs: 144 +/- 37 mu m) (P=.013), CA (frameworks: 89 +/- 12 mu m, complete contour FDPs: 110 +/- 22 mu m) (P=.006), and OC (frameworks: 182 +/- 36 mu m, complete contour FDPs: 244 +/- 64 mu m) (P=.008). At the measurement area AW (frameworks: 47 +/- 7 mu m, complete contour FDPs: 50 +/- 9 mu m of each location, no significant difference was observed between frameworks and complete contour FDPs (P=.361). Conclusions. Design differences in 3-unit FDPs fabricated from translucent multicolored zirconia influenced the marginal and internal fit. Frameworks had smaller marginal fit than complete contour FDPs for translucent multicolored zirconia.
引用
收藏
页码:340.e1 / 340.e6
页数:6
相关论文
共 50 条
  • [31] Comparison of marginal and internal fit of three-unit implant-supported fixed prosthetic substructures fabricated using CAD/CAM systems
    Ozlem Kayikci
    Sabit Melih Ates
    Clinical Oral Investigations, 2022, 26 : 1283 - 1291
  • [32] Comparison of marginal and internal fit of three-unit implant-supported fixed prosthetic substructures fabricated using CAD/CAM systems
    Kayikci, Ozlem
    Ates, Sabit Melih
    CLINICAL ORAL INVESTIGATIONS, 2022, 26 (02) : 1283 - 1291
  • [33] Digital measurement method for comparing the absolute marginal discrepancy of three-unit ceramic fixed dental prostheses fabricated using conventional and digital technologies
    Liang, Shanshan
    Yuan, Fusong
    Li, Deli
    Jia, Lu
    Sun, Yuchun
    BMC ORAL HEALTH, 2023, 23 (01)
  • [34] Digital measurement method for comparing the absolute marginal discrepancy of three-unit ceramic fixed dental prostheses fabricated using conventional and digital technologies
    Shanshan Liang
    Fusong Yuan
    Deli Li
    Lu Jia
    Yuchun Sun
    BMC Oral Health, 23
  • [35] Marginal Discrepancy and Internal Fit of Bi-Layered and Monolithic Zirconia Fixed Dental Prostheses: An In Vitro Study
    Alsarani, Majed
    Rizkalla, Amin
    Fava, Joseph
    Coyle, Thomas
    El-Mowafy, Omar
    APPLIED SCIENCES-BASEL, 2023, 13 (20):
  • [36] Marginal and internal fit and fracture resistance of three-unit provisional restorations fabricated by additive, subtractive, and conventional methods
    Falahchai, Mehran
    Rahimabadi, Samiye
    Khabazkar, Ghazaleh
    Hemmati, Yasamin Babaee
    Asli, Hamid Neshandar
    CLINICAL AND EXPERIMENTAL DENTAL RESEARCH, 2022, 8 (06): : 1404 - 1412
  • [37] Five-year prospective clinical study of posterior three-unit zirconia-based fixed dental prostheses
    Roberto Sorrentino
    Giorgio De Simone
    Stefano Tetè
    Simona Russo
    Fernando Zarone
    Clinical Oral Investigations, 2012, 16 : 977 - 985
  • [38] Accuracy, fit, and marginal quality of advanced additively manufactured and milled zirconia 3-unit fixed dental prostheses
    Wang, Yujie
    Zhou, Yi
    Zhu, Han
    Jiang, Jimin
    He, Fuming
    JOURNAL OF PROSTHETIC DENTISTRY, 2025, 133 (01): : 208e1 - 208e10
  • [39] Five-year prospective clinical study of posterior three-unit zirconia-based fixed dental prostheses
    Sorrentino, Roberto
    De Simone, Giorgio
    Tete, Stefano
    Russo, Simona
    Zarone, Fernando
    CLINICAL ORAL INVESTIGATIONS, 2012, 16 (03) : 977 - 985
  • [40] Three-unit posterior monolithic fixed dental prostheses made from high-translucent shade-graded zirconia: 3-Year results from a prospective clinical pilot study
    Jan-Frederik Güth
    Christine Keul
    Anja Liebermann
    Josef Schweiger
    Daniel Edelhoff
    Oliver Schubert
    Clinical Oral Investigations, 29 (1)