Marginal and internal fit of three-unit fixed dental prostheses fabricated from translucent multicolored zirconia: Framework versus complete contour design

被引:2
|
作者
Ueda, Kazuhiko [1 ]
Watanabe, Fumihiko [1 ]
Katsuta, Yasuhiro [1 ]
Seto, Munetsugu [1 ]
Ueno, Daisuke [1 ]
Hiroyasu, Kazuhiko [2 ]
Suzuki, Shohei [1 ]
Erdelt, Kurt [3 ]
Gueth, Jan-Frederik [3 ]
机构
[1] Nippon Dent Univ, Sch Life Dent Niigata, Dept Crown & Bridge Prosthodont, Niigata, Japan
[2] Nippon Dent Univ, Oral Implant Care Unit, Niigata Hosp, Niigata, Japan
[3] Ludwig Maximilians Univ Munchen, Univ Hosp, Dept Prosthet Dent, Munich, Germany
来源
JOURNAL OF PROSTHETIC DENTISTRY | 2021年 / 125卷 / 02期
关键词
D O I
10.1016/j.prosdent.2020.08.023
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. Translucent multicolored zirconia materials enable more esthetic complete contour zirconia fixed dental prostheses (FDPs) than conventional zirconia, which exhibits low translucency and high opacity and is monochromatic. However, how the marginal and internal fit of translucent multicolored zirconia FDPs compare with those of traditional frameworks that require veneering is unclear. Purpose. The purpose of this in vitro study was to compare the marginal and internal fit of frameworks and complete contour 3-unit FDPs fabricated from translucent multicolored zirconia. Material and methods. Frameworks with a thickness of 0.5 mm and complete contour FDPs with a thickness of 0.8 to 1.5 mm were manufactured by using a workflow similar to one from a zirconia master model (mandibular left second premolar-mandibular left second molar). Two polyvinyl siloxane replicas were made for each specimen to measure the marginal and internal fit. Measurement locations were mesial, lingual, buccal, and distal for each abutment. In these locations, the marginal opening (MO), chamfer area (CA), axial wall (AW), and occlusal area (OC) were measured. The data were analyzed with 2-way ANOVA and the Bonferroni post hoc test (alpha=.05). Results. Frameworks showed significantly better mean +/- standard deviation fit values than complete contour 3-unit FDPs at measurement areas MO (frameworks: 112 +/- 22 mu m, complete contour FDPs: 144 +/- 37 mu m) (P=.013), CA (frameworks: 89 +/- 12 mu m, complete contour FDPs: 110 +/- 22 mu m) (P=.006), and OC (frameworks: 182 +/- 36 mu m, complete contour FDPs: 244 +/- 64 mu m) (P=.008). At the measurement area AW (frameworks: 47 +/- 7 mu m, complete contour FDPs: 50 +/- 9 mu m of each location, no significant difference was observed between frameworks and complete contour FDPs (P=.361). Conclusions. Design differences in 3-unit FDPs fabricated from translucent multicolored zirconia influenced the marginal and internal fit. Frameworks had smaller marginal fit than complete contour FDPs for translucent multicolored zirconia.
引用
收藏
页码:340.e1 / 340.e6
页数:6
相关论文
共 50 条
  • [1] Marginal and internal fit of three-unit zirconia fixed dental prostheses: Effects of prosthesis design, cement space, and zirconia type
    Suzuki, Shohei
    Katsuta, Yasuhiro
    Ueda, Kazuhiko
    Watanabe, Fumihiko
    JOURNAL OF PROSTHODONTIC RESEARCH, 2020, 64 (04) : 460 - 467
  • [2] Precision of fit: zirconia three-unit fixed dental prostheses
    Beuer, Florian
    Naumann, Michael
    Gernet, Wolfgang
    Sorensen, John A.
    CLINICAL ORAL INVESTIGATIONS, 2009, 13 (03) : 343 - 349
  • [3] Precision of fit: zirconia three-unit fixed dental prostheses
    Florian Beuer
    Michael Naumann
    Wolfgang Gernet
    John A. Sorensen
    Clinical Oral Investigations, 2009, 13
  • [4] Marginal and internal fit of posterior three-unit fixed zirconia dental prostheses fabricated with two different CAD/CAM systems and materials
    Schoenberger, Joana
    Erdelt, Kurt-Juergen
    Baeumer, Daniel
    Beuer, Florian
    CLINICAL ORAL INVESTIGATIONS, 2017, 21 (08) : 2629 - 2635
  • [5] Marginal and internal fit of posterior three-unit fixed zirconia dental prostheses fabricated with two different CAD/CAM systems and materials
    Joana Schönberger
    Kurt-Jürgen Erdelt
    Daniel Bäumer
    Florian Beuer
    Clinical Oral Investigations, 2017, 21 : 2629 - 2635
  • [6] An evaluation of marginal fit of three-unit fixed dental prostheses fabricated by direct metal laser sintering system
    Kim, Ki-Baek
    Kim, Woong-Chul
    Kim, Hae-Young
    Kim, Ji-Hwan
    DENTAL MATERIALS, 2013, 29 (07) : E91 - E96
  • [7] Marginal and internal fit of zirconia based fixed dental prostheses fabricated with different concepts
    Beuer, Florian
    Korczynski, Natalie
    Rezac, Antonia
    Naumann, Michael
    Gernet, Wolfgang
    Sorensen, John A.
    CLINICAL COSMETIC AND INVESTIGATIONAL DENTISTRY, 2010, 2 : 5 - 11
  • [8] Effect of connector configuration on the fracture load in conventional and translucent zirconia three-unit fixed dental prostheses
    Subsomboon, Chonticha
    Urapepon, Somchai
    JOURNAL OF ADVANCED PROSTHODONTICS, 2023, 15 (04): : 171 - 178
  • [9] In vitro evaluation of marginal and internal adaptation of three-unit fixed dental prostheses produced by stereolithography
    Kim, Ki-Baek
    Kim, Jae-Hong
    Kim, Woong-Chul
    Kim, Ji-Hwan
    DENTAL MATERIALS JOURNAL, 2014, 33 (04) : 504 - 509
  • [10] Effects of porcelain veneering methods on conformity of the marginal and internal fit of three-unit zirconia framework
    Shohei Suzuki
    Kazuhiko Ueda
    Kurt Erdelt
    Fumihiko Watanabe
    Jan-Frederik Güth