Marginal and internal fit of three-unit zirconia fixed dental prostheses: Effects of prosthesis design, cement space, and zirconia type

被引:17
|
作者
Suzuki, Shohei [1 ]
Katsuta, Yasuhiro [2 ]
Ueda, Kazuhiko [2 ]
Watanabe, Fumihiko [1 ,2 ]
机构
[1] Nippon Dent Univ, Sch Life Dent Niigata, Dept Crown & Bridge Prosthodont, Funct Occlusal Treatment,Chuo Ku, 1-8 Hamaura Cho, Niigata 9518580, Japan
[2] Nippon Dent Univ, Sch Life Dent, Dept Crown & Bridge Prosthodont, Niigata, Japan
关键词
MONOLITHIC ZIRCONIA; CERAMIC CROWNS; 4-UNIT FDPS; FRACTURE; SYSTEMS; COCR; LOAD;
D O I
10.1016/j.jpor.2019.12.005
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: The purpose of this study was to compare the marginal and internal fit of three-unit fixed dental prostheses (FDPs) fabricated using CAD/CAM with two designs, two cement space (CS), and two zirconia types. Methods: A master model with two zirconia abutments and a missing tooth was scanned with an intraoral scanner. FDPs were fabricated with two designs (Full contour: FC, Framework: FW), two zirconia types (multi-layer: L, single-layer: W), and two CS values (30 and 45 mu m for L and 30 mu m for W). There were six experimental groups. The fit of the FDPs was evaluated using the replica method. The space between an abutment and the FDPs in the marginal (MO), chamfer (CH), axial (AX), and occlusal (OC) areas was measured under an optical microscope and the data was statistically analyzed using three-way ANOVA and Bonferroni test (p < 0.05). Results: FW-L-45 mu m showed a significantly smaller space than those for the FC in MO (p = 0.011), CH (p = 0.001) and AXE (p = 0.003). FW-L-30 mu m showed a significantly smaller space than that for the 45 mu m in AXE (p = 0.000) and OC (p = 0.016). FW-W-30 mu m showed a significantly smaller space than that for the L in MO (p = 0.000), CH (p = 0.000), AXE (p = 0.000), and OC (p = 0.002). Conclusions: The design and CS of the FDPs affected the fit. FDPs with single-layer zirconia showed better fit than that obtained with multi-layer zirconia. (C) 2020 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:460 / 467
页数:8
相关论文
共 50 条
  • [1] Precision of fit: zirconia three-unit fixed dental prostheses
    Beuer, Florian
    Naumann, Michael
    Gernet, Wolfgang
    Sorensen, John A.
    CLINICAL ORAL INVESTIGATIONS, 2009, 13 (03) : 343 - 349
  • [2] Precision of fit: zirconia three-unit fixed dental prostheses
    Florian Beuer
    Michael Naumann
    Wolfgang Gernet
    John A. Sorensen
    Clinical Oral Investigations, 2009, 13
  • [3] Marginal and internal fit of three-unit fixed dental prostheses fabricated from translucent multicolored zirconia: Framework versus complete contour design
    Ueda, Kazuhiko
    Watanabe, Fumihiko
    Katsuta, Yasuhiro
    Seto, Munetsugu
    Ueno, Daisuke
    Hiroyasu, Kazuhiko
    Suzuki, Shohei
    Erdelt, Kurt
    Gueth, Jan-Frederik
    JOURNAL OF PROSTHETIC DENTISTRY, 2021, 125 (02): : 340.e1 - 340.e6
  • [4] Marginal and internal fit of posterior three-unit fixed zirconia dental prostheses fabricated with two different CAD/CAM systems and materials
    Schoenberger, Joana
    Erdelt, Kurt-Juergen
    Baeumer, Daniel
    Beuer, Florian
    CLINICAL ORAL INVESTIGATIONS, 2017, 21 (08) : 2629 - 2635
  • [5] Marginal and internal fit of posterior three-unit fixed zirconia dental prostheses fabricated with two different CAD/CAM systems and materials
    Joana Schönberger
    Kurt-Jürgen Erdelt
    Daniel Bäumer
    Florian Beuer
    Clinical Oral Investigations, 2017, 21 : 2629 - 2635
  • [6] Evaluation of Marginal and Internal Fit of Presintered Co-Cr and Zirconia Three-Unit Fixed Dental Prosthesis Compared to Cast Co-Cr
    Daou, Elie E.
    Baba, Nadim Z.
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2020, 29 (09): : 792 - 799
  • [7] Marginal fit of 14-unit zirconia fixed dental prosthesis retainers
    Beuer, F.
    Neumeier, P.
    Naumann, M.
    JOURNAL OF ORAL REHABILITATION, 2009, 36 (02) : 142 - 149
  • [8] Effects of porcelain veneering methods on conformity of the marginal and internal fit of three-unit zirconia framework
    Shohei Suzuki
    Kazuhiko Ueda
    Kurt Erdelt
    Fumihiko Watanabe
    Jan-Frederik Güth
    Odontology, 2021, 109 : 719 - 728
  • [9] Effects of porcelain veneering methods on conformity of the marginal and internal fit of three-unit zirconia framework
    Suzuki, Shohei
    Ueda, Kazuhiko
    Erdelt, Kurt
    Watanabe, Fumihiko
    Gueth, Jan-Frederik
    ODONTOLOGY, 2021, 109 (03) : 719 - 728
  • [10] Marginal and internal fit of zirconia based fixed dental prostheses fabricated with different concepts
    Beuer, Florian
    Korczynski, Natalie
    Rezac, Antonia
    Naumann, Michael
    Gernet, Wolfgang
    Sorensen, John A.
    CLINICAL COSMETIC AND INVESTIGATIONAL DENTISTRY, 2010, 2 : 5 - 11