Marginal and internal fit of three-unit zirconia fixed dental prostheses: Effects of prosthesis design, cement space, and zirconia type

被引:17
|
作者
Suzuki, Shohei [1 ]
Katsuta, Yasuhiro [2 ]
Ueda, Kazuhiko [2 ]
Watanabe, Fumihiko [1 ,2 ]
机构
[1] Nippon Dent Univ, Sch Life Dent Niigata, Dept Crown & Bridge Prosthodont, Funct Occlusal Treatment,Chuo Ku, 1-8 Hamaura Cho, Niigata 9518580, Japan
[2] Nippon Dent Univ, Sch Life Dent, Dept Crown & Bridge Prosthodont, Niigata, Japan
关键词
MONOLITHIC ZIRCONIA; CERAMIC CROWNS; 4-UNIT FDPS; FRACTURE; SYSTEMS; COCR; LOAD;
D O I
10.1016/j.jpor.2019.12.005
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: The purpose of this study was to compare the marginal and internal fit of three-unit fixed dental prostheses (FDPs) fabricated using CAD/CAM with two designs, two cement space (CS), and two zirconia types. Methods: A master model with two zirconia abutments and a missing tooth was scanned with an intraoral scanner. FDPs were fabricated with two designs (Full contour: FC, Framework: FW), two zirconia types (multi-layer: L, single-layer: W), and two CS values (30 and 45 mu m for L and 30 mu m for W). There were six experimental groups. The fit of the FDPs was evaluated using the replica method. The space between an abutment and the FDPs in the marginal (MO), chamfer (CH), axial (AX), and occlusal (OC) areas was measured under an optical microscope and the data was statistically analyzed using three-way ANOVA and Bonferroni test (p < 0.05). Results: FW-L-45 mu m showed a significantly smaller space than those for the FC in MO (p = 0.011), CH (p = 0.001) and AXE (p = 0.003). FW-L-30 mu m showed a significantly smaller space than that for the 45 mu m in AXE (p = 0.000) and OC (p = 0.016). FW-W-30 mu m showed a significantly smaller space than that for the L in MO (p = 0.000), CH (p = 0.000), AXE (p = 0.000), and OC (p = 0.002). Conclusions: The design and CS of the FDPs affected the fit. FDPs with single-layer zirconia showed better fit than that obtained with multi-layer zirconia. (C) 2020 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:460 / 467
页数:8
相关论文
共 50 条
  • [41] Comparison of marginal and internal adaptation of three-unit fixed dental prostheses made using CAD/CAM metal-free materials
    Baran, Melike Cigdem
    Demirci, Fatih
    Tuzlali, Mesut
    EUROPEAN JOURNAL OF ORAL SCIENCES, 2022, 130 (06)
  • [42] One-Piece Zirconia Oral Implants for the Support of Three-Unit Fixed Dental Prostheses: Three-Year Results from a Prospective Case Series
    Kohal, Ralf-Joachim
    Vach, Kirstin
    Butz, Frank
    Spies, Benedikt Christopher
    Patzelt, Sebastian Berthold Maximilian
    Burkhardt, Felix
    JOURNAL OF FUNCTIONAL BIOMATERIALS, 2023, 14 (01)
  • [43] Marginal fit and retention force of zirconia resin-bonded fixed dental prostheses in the posterior region with different designs
    Yin, Yue
    Nozaki, Kosuke
    Nemoto, Reina
    Saleh, Omnia
    Oishi, Yayoi
    Matsumura, Mayuko
    Komada, Wataru
    Miura, Hiroyuki
    Fueki, Kenji
    JOURNAL OF DENTAL SCIENCES, 2024, 19 (03) : 1587 - 1594
  • [44] Fracture resistance of three-unit zirconia fixed partial denture with modified framework
    Arthur Partiyan
    Essam Osman
    Mohammad M. Rayyan
    Moustafa Aboushelib
    Ahmed Ibrahim
    Ryo Jimbo
    Odontology, 2017, 105 : 62 - 67
  • [45] Fracture resistance of three-unit zirconia fixed partial denture with modified framework
    Partiyan, Arthur
    Osman, Essam
    Rayyan, Mohammad M.
    Aboushelib, Moustafa
    Ibrahim, Ahmed
    Jimbo, Ryo
    ODONTOLOGY, 2017, 105 (01) : 62 - 67
  • [46] Fracture Strength, Failure Types, and Weibull Characteristics of Three-Unit Zirconia Fixed Dental Prostheses After Cyclic Loading: Effects of Veneering and Air-Abrasion Protocols
    Campos, Femanda
    Souza, Rodrigo O. A.
    Bottino, Marco A.
    Ozcan, Mutiu
    INTERNATIONAL JOURNAL OF PERIODONTICS & RESTORATIVE DENTISTRY, 2016, 36 (06) : 901 - 908
  • [47] Effect of different sintering procedures on marginal and internal fit, color, and fracture load of monolithic zirconia fixed partial prostheses
    Eraslan, Ravza
    Sahin, Baharsayin
    Albayrak, Haydar
    Ayata, Mustafa
    Temizkanli, Ozan
    INTERNATIONAL JOURNAL OF COMPUTERIZED DENTISTRY, 2024, 27 (03)
  • [48] Clinical prospective evaluation of zirconia-based three-unit posterior fixed dental prostheses: Up-to ten-year results.
    Ioannidis, Alexis
    Bindl, Andreas
    JOURNAL OF DENTISTRY, 2016, 47 : 80 - 85
  • [49] Comparison of the overall fit of three-unit posterior fixed dental prostheses fabricated with laser sintering and conventional casting methods
    Pekkan, Gurel
    Degirmenci, Kubra
    Tuna, Suleyman Hakan
    Hekimoglu, Canan
    Saridag, Serkan
    CLINICAL ORAL INVESTIGATIONS, 2025, 29 (03)
  • [50] A Comparison Study of Marginal and Internal Fit Assessment Methods for Fixed Dental Prostheses
    Son, Keunbada
    Lee, Sangbong
    Kang, Seok Hyon
    Park, Jaeseok
    Lee, Kyu-Bok
    Jeon, Mansik
    Yun, Byoung-Ju
    JOURNAL OF CLINICAL MEDICINE, 2019, 8 (06)