Marginal and internal fit of three-unit zirconia fixed dental prostheses: Effects of prosthesis design, cement space, and zirconia type

被引:17
|
作者
Suzuki, Shohei [1 ]
Katsuta, Yasuhiro [2 ]
Ueda, Kazuhiko [2 ]
Watanabe, Fumihiko [1 ,2 ]
机构
[1] Nippon Dent Univ, Sch Life Dent Niigata, Dept Crown & Bridge Prosthodont, Funct Occlusal Treatment,Chuo Ku, 1-8 Hamaura Cho, Niigata 9518580, Japan
[2] Nippon Dent Univ, Sch Life Dent, Dept Crown & Bridge Prosthodont, Niigata, Japan
关键词
MONOLITHIC ZIRCONIA; CERAMIC CROWNS; 4-UNIT FDPS; FRACTURE; SYSTEMS; COCR; LOAD;
D O I
10.1016/j.jpor.2019.12.005
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: The purpose of this study was to compare the marginal and internal fit of three-unit fixed dental prostheses (FDPs) fabricated using CAD/CAM with two designs, two cement space (CS), and two zirconia types. Methods: A master model with two zirconia abutments and a missing tooth was scanned with an intraoral scanner. FDPs were fabricated with two designs (Full contour: FC, Framework: FW), two zirconia types (multi-layer: L, single-layer: W), and two CS values (30 and 45 mu m for L and 30 mu m for W). There were six experimental groups. The fit of the FDPs was evaluated using the replica method. The space between an abutment and the FDPs in the marginal (MO), chamfer (CH), axial (AX), and occlusal (OC) areas was measured under an optical microscope and the data was statistically analyzed using three-way ANOVA and Bonferroni test (p < 0.05). Results: FW-L-45 mu m showed a significantly smaller space than those for the FC in MO (p = 0.011), CH (p = 0.001) and AXE (p = 0.003). FW-L-30 mu m showed a significantly smaller space than that for the 45 mu m in AXE (p = 0.000) and OC (p = 0.016). FW-W-30 mu m showed a significantly smaller space than that for the L in MO (p = 0.000), CH (p = 0.000), AXE (p = 0.000), and OC (p = 0.002). Conclusions: The design and CS of the FDPs affected the fit. FDPs with single-layer zirconia showed better fit than that obtained with multi-layer zirconia. (C) 2020 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:460 / 467
页数:8
相关论文
共 50 条
  • [31] Five-year prospective clinical study of posterior three-unit zirconia-based fixed dental prostheses
    Sorrentino, Roberto
    De Simone, Giorgio
    Tete, Stefano
    Russo, Simona
    Zarone, Fernando
    CLINICAL ORAL INVESTIGATIONS, 2012, 16 (03) : 977 - 985
  • [32] Evaluation of the fit of zirconia three-unit fixed partial dentures fabricated by different impression techniques
    Moustapha, Ghassan
    Azzam, Khaled
    AlShwaimi, Emad
    Silwadi, Munir
    Ferraris, Marco
    Salameh, Ziad
    JOURNAL OF INVESTIGATIVE AND CLINICAL DENTISTRY, 2019, 10 (03)
  • [33] Fracture Resistance of Straight and Angulated Zirconia Implant Abutments Supporting Anterior Three-Unit Lithium Disilicate Fixed Dental Prostheses
    Saker, Samah
    El-Shahat, Sameh
    Ghazy, Mohamed
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2016, 31 (06) : 1240 - 1246
  • [34] Marginal and internal fit of curved anterior CAD/CAM-milled zirconia fixed dental prostheses: An in-vitro study
    Buechi, Dominik L.
    Ebler, Sabine
    Haemmerle, Christoph H. F.
    Sailer, Irena
    QUINTESSENCE INTERNATIONAL, 2014, 45 (10): : 837 - 846
  • [35] Five-Year Results of One-Piece Zirconia Oral Implants Supporting Three-Unit Fixed Dental Prostheses
    Kohal, Ralf-Joachim
    Vach, Kirstin
    Butz, Frank
    Patzelt, Sebastian Berthold Maximilian
    Burkhardt, Felix
    CLINICAL ORAL IMPLANTS RESEARCH, 2025,
  • [36] Comparison of marginal and internal fit of 5-unit zirconia fixed dental prostheses fabricated with CAD/CAM technology using direct and indirect digital scans
    Uluc, Irem Gokce
    Guncu, Mustafa Baris
    Aktas, Guliz
    Turkyilmaz, Ilser
    JOURNAL OF DENTAL SCIENCES, 2022, 17 (01) : 63 - 69
  • [37] Marginal and internal fit of five-unit zirconia-based fixed dental prostheses fabricated with digital scans and conventional impressions: A comparative in vitro study
    Bandiaky, Octave Nadile
    Clouet, Roselyne
    Le Bars, Pierre
    Soueidan, Assem
    Le Guehennec, Laurent
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2023, 32 (09): : 846 - 853
  • [38] Marginal and internal fit of pre-sintered Co-Cr and zirconia 3-unit fixed dental prostheses as measured using microcomputed tomography
    Daou, Elie E.
    Ounsi, Hani
    Ozcan, Mutlu
    Husain, Nadin Al-Haj
    Salameh, Ziad
    JOURNAL OF PROSTHETIC DENTISTRY, 2018, 120 (03): : 409 - 414
  • [39] Comparative Evaluation of Load-Bearing Capacity and Fracture Analysis of PEEK and Zirconia Three-Unit Fixed Dental Prostheses: An In Vitro Study
    Jain, Radhika A.
    Gupta, Rekha
    Verma, Mahesh
    Nanda, Aditi
    Gill, Shubhra
    Mehra, Rashmi
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2022, 35 (02) : 225 - 232
  • [40] Three-year analysis of zirconia implants used for single-tooth replacement and three-unit fixed dental prostheses: A prospective multicenter study
    Balmer, Marc
    Spies, Benedikt C.
    Vach, Kirstin
    Kohal, Ralf-Joachim
    Hammerle, Christoph H. F.
    Jung, Ronald E.
    CLINICAL ORAL IMPLANTS RESEARCH, 2018, 29 (03) : 290 - 299