Effect of different sintering procedures on marginal and internal fit, color, and fracture load of monolithic zirconia fixed partial prostheses

被引:0
|
作者
Eraslan, Ravza [1 ]
Sahin, Baharsayin
Albayrak, Haydar [1 ]
Ayata, Mustafa
Temizkanli, Ozan
机构
[1] Erciyes Univ, Fac Dent, Dept Prosthodont, Kayseri, Turkiye
关键词
color; fit; fracture load; sintering; zirconia; FLEXURAL STRENGTH; OPTICAL-PROPERTIES; GRAIN-SIZE; TEMPERATURE; TRANSLUCENT; THRESHOLDS; CERAMICS; ACCURACY;
D O I
10.3290/picd.b5114621
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Aim: The aim of the present in vitro study was to investigate the effects of different sintering procedures on the fit, color parameters, and fracture load of monolithic fixed partial prostheses (FPPs). Materials and methods: A metal master model was scanned and FPPs were designed. Groups were created by fabricating FPPs using four different sintering procedures (n = 10): Prettau-Standard (PST); Prettau-Slow (PSL); Ice-Speed (ISP); Ice-Standard (1ST). PST-PSL (Group P; N = 20) and ISP-IST (Group I; N = 20) were colored with different coloring liquids. The marginal and internal fit were measured using the silicone replica method. CIELAB values of the samples were measured using a spectrophotometer. Then, for each sample, the die was obtained from polymethyl methacrylate. The specimens were cemented into dies and tested in a universal testing machine for fracture load. One-way ANOVA was performed to assess the effect of the sintering procedure on the marginal and internal fit; fracture load; and AE00, AL', AC', and OH'values of the FPPs. Results: The PSL and PST groups showed significantly smaller internal and marginal fit values compared with the ISP group. Additionally, the internal fit values of the 1ST group were significantly higher than those of Group P. Sintering time reduction led to a decrease in AE00 values. Fracture load values were not statistically significantly affected by the different sintering procedures for both brands. Conclusion: Different sintering procedures did not have a clinically significant effect on fit and fracture load. Different sintering procedures were found to have an impact on the color change of monolithic zirconia restorations. (Int J Comput Dent 2024;27(3):281-290; doi: 10.3290/picd.b5114621)
引用
收藏
页数:100
相关论文
共 50 条
  • [1] Marginal and internal fit of zirconia based fixed dental prostheses fabricated with different concepts
    Beuer, Florian
    Korczynski, Natalie
    Rezac, Antonia
    Naumann, Michael
    Gernet, Wolfgang
    Sorensen, John A.
    CLINICAL COSMETIC AND INVESTIGATIONAL DENTISTRY, 2010, 2 : 5 - 11
  • [2] MARGINAL AND INTERNAL FIT OF PARTIAL-RETAINER CAD/CAM ZIRCONIA FIXED DENTAL PROSTHESES
    Candea, Adrian
    Jivanescu, Anca
    Leretter, Marius
    Rominu, Mihai
    PROCEEDINGS OF THE ROMANIAN ACADEMY SERIES A-MATHEMATICS PHYSICS TECHNICAL SCIENCES INFORMATION SCIENCE, 2017, 18 (04): : 345 - 352
  • [3] The effect of pre-ceramic soldering on marginal and internal fit of 4-unit zirconia frameworks and monolithic zirconia fixed dental prostheses
    Diler Ozkan Irem
    Dilara Seyma Alpkilic
    Sabire Isler Deger
    Odontology, 2024, 112 : 169 - 176
  • [4] The effect of pre-ceramic soldering on marginal and internal fit of 4-unit zirconia frameworks and monolithic zirconia fixed dental prostheses
    Irem, Diler Ozkan
    Alpkilic, Dilara Seyma
    Deger, Sabire Isler
    ODONTOLOGY, 2024, 112 (01) : 169 - 176
  • [5] Marginal Discrepancy and Internal Fit of Bi-Layered and Monolithic Zirconia Fixed Dental Prostheses: An In Vitro Study
    Alsarani, Majed
    Rizkalla, Amin
    Fava, Joseph
    Coyle, Thomas
    El-Mowafy, Omar
    APPLIED SCIENCES-BASEL, 2023, 13 (20):
  • [6] The Effect of Sintering Procedures on Fit and Color in Zirconia Crowns
    Albayrak, Haydar
    Eraslan, Ravza
    Temizkanli, Ozan
    Sahin, Bahar Sayin
    Ayata, Mustafa
    Sezer, Taygun
    JOURNAL OF ADVANCED ORAL RESEARCH, 2022, 13 (02) : 245 - 251
  • [7] Evaluation of Marginal/Internal Fit and Fracture Load of Monolithic Zirconia and Zirconia Lithium Silicate (ZLS) CAD/CAM Crown Systems
    Sadeqi, Haneen A.
    Baig, Mirza Rustum
    Al-Shammari, Mohammad
    MATERIALS, 2021, 14 (21)
  • [8] Influence of speed sintering on the fit and fracture strength of 3-unit monolithic zirconia fixed partial dentures
    Kauling, Ana Elisa
    Gueth, Jan-Frederik
    Erdelt, Kurt
    Edelhoff, Daniel
    Keul, Christine
    JOURNAL OF PROSTHETIC DENTISTRY, 2020, 124 (03): : 380 - 386
  • [9] Effect of Sintering Speed and Polishing or Glazing on the Failure Load of Monolithic Zirconia Fixed Partial Dentures
    Hafezeqoran, Ali
    Sabanik, Pouya
    Koodaryan, Roodabeh
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2022, 35 (04) : 405 - 409
  • [10] Marginal discrepancy and load to fracture of monolithic zirconia laminate veneers: The effect of preparation design and sintering protocol
    Saker, Samah
    Ozcan, Mutlu
    DENTAL MATERIALS JOURNAL, 2021, 40 (02) : 331 - 338