Effect of different sintering procedures on marginal and internal fit, color, and fracture load of monolithic zirconia fixed partial prostheses

被引:0
|
作者
Eraslan, Ravza [1 ]
Sahin, Baharsayin
Albayrak, Haydar [1 ]
Ayata, Mustafa
Temizkanli, Ozan
机构
[1] Erciyes Univ, Fac Dent, Dept Prosthodont, Kayseri, Turkiye
关键词
color; fit; fracture load; sintering; zirconia; FLEXURAL STRENGTH; OPTICAL-PROPERTIES; GRAIN-SIZE; TEMPERATURE; TRANSLUCENT; THRESHOLDS; CERAMICS; ACCURACY;
D O I
10.3290/picd.b5114621
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Aim: The aim of the present in vitro study was to investigate the effects of different sintering procedures on the fit, color parameters, and fracture load of monolithic fixed partial prostheses (FPPs). Materials and methods: A metal master model was scanned and FPPs were designed. Groups were created by fabricating FPPs using four different sintering procedures (n = 10): Prettau-Standard (PST); Prettau-Slow (PSL); Ice-Speed (ISP); Ice-Standard (1ST). PST-PSL (Group P; N = 20) and ISP-IST (Group I; N = 20) were colored with different coloring liquids. The marginal and internal fit were measured using the silicone replica method. CIELAB values of the samples were measured using a spectrophotometer. Then, for each sample, the die was obtained from polymethyl methacrylate. The specimens were cemented into dies and tested in a universal testing machine for fracture load. One-way ANOVA was performed to assess the effect of the sintering procedure on the marginal and internal fit; fracture load; and AE00, AL', AC', and OH'values of the FPPs. Results: The PSL and PST groups showed significantly smaller internal and marginal fit values compared with the ISP group. Additionally, the internal fit values of the 1ST group were significantly higher than those of Group P. Sintering time reduction led to a decrease in AE00 values. Fracture load values were not statistically significantly affected by the different sintering procedures for both brands. Conclusion: Different sintering procedures did not have a clinically significant effect on fit and fracture load. Different sintering procedures were found to have an impact on the color change of monolithic zirconia restorations. (Int J Comput Dent 2024;27(3):281-290; doi: 10.3290/picd.b5114621)
引用
收藏
页数:100
相关论文
共 50 条
  • [31] Evaluation of fracture resistance of inlay-retained fixed partial dentures fabricated with different monolithic zirconia materials
    Gumus, Hilal Siriner
    Polat, Nilufer Tulin
    Yildirim, Guler
    JOURNAL OF PROSTHETIC DENTISTRY, 2018, 119 (06): : 959 - 964
  • [32] Load-Bearing Capacity of Monolithic Zirconia Fixed Dental Prostheses Fabricated with Different Connector Designs and Embrasure Shaping Methods
    Bakitian, Fahad
    Seweryniak, Przemek
    Papia, Evaggelia
    Larsson, Christel
    von Steyern, Per Vult
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2019, 28 (01): : 64 - 70
  • [33] Different Cavity Designs with Additional Wings Increase the Fracture Resistance of Inlay-Retained Monolithic Zirconia Fixed Dental Prostheses
    Kececi, Murat
    Buyukerkmen, Emine Begum
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2022, 35 (04) : 487 - 493
  • [34] The Effect of Different Marginal Cement Space Thickness on the Fracture Strength of Monolithic Zirconia Crowns Using Different Luting Agents
    Hussien, Ibtehal M.
    Ibraheem, Adel F.
    JOURNAL OF RESEARCH IN MEDICAL AND DENTAL SCIENCE, 2022, 10 (04): : 48 - 52
  • [35] Effect of connector configuration on the fracture load in conventional and translucent zirconia three-unit fixed dental prostheses
    Subsomboon, Chonticha
    Urapepon, Somchai
    JOURNAL OF ADVANCED PROSTHODONTICS, 2023, 15 (04): : 171 - 178
  • [36] Influence of porcelain firing on changes in the marginal fit of metal-ceramic fixed partial dental prostheses fabricated with laser sintering: An in vivo study
    Nassif, Qusay Khaznadar
    Alshaarani, Fendi Fendi
    DENTAL AND MEDICAL PROBLEMS, 2020, 57 (02) : 185 - 190
  • [37] Fracture Resistance and Fracture Behaviour of Monolithic Multi-Layered Translucent Zirconia Fixed Dental Prostheses with Different Placing Strategies of Connector: An in vitro Study
    Heidari, Nada
    Amawi, Rasha
    Seweryniak, Przemek
    Bakitian, Fahad
    von Steyern, Per Vult
    CLINICAL COSMETIC AND INVESTIGATIONAL DENTISTRY, 2022, 14 : 61 - 69
  • [38] Influence of CAD/CAM Fabrication and Sintering Procedures on the Fracture Load of Full-Contour Monolithic Zirconia Crowns as a Function of Material Thickness
    Zimmermann, M.
    Ender, A.
    Mehl, A.
    OPERATIVE DENTISTRY, 2020, 45 (02) : 219 - 226
  • [39] Marginal and internal fit of three-unit fixed dental prostheses fabricated from translucent multicolored zirconia: Framework versus complete contour design
    Ueda, Kazuhiko
    Watanabe, Fumihiko
    Katsuta, Yasuhiro
    Seto, Munetsugu
    Ueno, Daisuke
    Hiroyasu, Kazuhiko
    Suzuki, Shohei
    Erdelt, Kurt
    Gueth, Jan-Frederik
    JOURNAL OF PROSTHETIC DENTISTRY, 2021, 125 (02): : 340.e1 - 340.e6
  • [40] Effect of low-temperature degradation and sintering protocols on the color of monolithic zirconia crowns with different yttria contents
    Miura, Shoko
    Shinya, Akikazu
    Koizumi, Hiroyasu
    Vallittu, Pekka
    Lassila, Lippo
    Fujisawa, Masanori
    DENTAL MATERIALS JOURNAL, 2024, 43 (02) : 164 - 171