An ECG measurement IC using driven-right-leg circuit

被引:15
|
作者
Wong, Alex [1 ]
Pun, Kong-Pang [1 ]
Zhang, Yuan-Ting [1 ]
Choy, Chiu-Sing [1 ]
机构
[1] Chinese Univ Hong Kong, Dept Elect Engn, Shatin, Hong Kong, Peoples R China
关键词
D O I
10.1109/ISCAS.2006.1692593
中图分类号
TP3 [计算技术、计算机技术];
学科分类号
0812 ;
摘要
In this paper, an electrocardiographic (ECG) signal processing IC, which will be used for portable biomedical application, was designed using continuous-time technique. The circuit consists of an instrumentation amplifier (INA) with driven-right-leg circuit (DRL), a 5(th) order G(m)-C low pass filter (G(m)-C LPF) operating in sub-threshold mode, and amplifiers. DRL circuit is used to detect small amplitude signal in the presence of large common-mode voltage from the human body. The CMRR of the INA is 78 dB and the G(m)-C LPF has a cutoff frequency of 18 Hz. As a result of using the DRL, a small signal can be detected in the presence of large common-mode differential. The circuit consumes 1.23 mW when operating from with a supply voltage of +/- 1.5-V and occupies a core area of 0.94 mm(2). The circuit was designed in a 0.35 mu m CMOS process and simulation results have successfully demonstrated the functionalitics.
引用
收藏
页码:345 / +
页数:2
相关论文
共 50 条
  • [41] Digital Twin Driven Measurement in Robotic Flexible Printed Circuit Assembly
    Yang, Minghao
    Huang, Zhenping
    Sun, Yangchang
    Zhao, Yongjia
    Sun, Ruize
    Sun, Qi
    Chen, Jinlong
    Qiang, Baohua
    Wang, Jinghong
    Sun, Fuchun
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2023, 72
  • [42] Research on ultrasonic transducer and its driven circuit applied in measurement of distance
    Meng, L.
    Zheng, B.
    Hou, W.
    Huabei Gongxueyuan Xuebao/Journal of North China Institute of Technology, 2001, 22 (02): : 87 - 89
  • [43] Fast Simulation of PCB/IC/Flex Circuit Assembly Using Partial Element Equivalent Circuit Method
    Gabriadze, G.
    Chiqovani, G.
    Demurov, A.
    Kutchadze, Z.
    Karkashadze, D.
    Jobava, R.
    2018 INTERNATIONAL SYMPOSIUM ON ELECTROMAGNETIC COMPATIBILITY (EMC EUROPE), 2018, : 467 - 472
  • [44] INSPIRATORY FORCE MEASUREMENT USING ANESTHESIA CIRCUIT
    SUWA, K
    BENDIXEN, HH
    ANESTHESIOLOGY, 1967, 28 (01) : 209 - &
  • [45] A urinary bladder volume measurement circuit using a simplified very small phase difference measurement circuit
    Noguchi T.
    Fukai S.
    Ishikawa Y.
    Shimizu A.
    Kimoto A.
    Toyoda I.
    Noguchi, Takuro (takuro@ariake-nct.ac.jp), 1600, Institute of Electrical Engineers of Japan (137): : 1304 - 1309
  • [46] A Urinary Bladder Volume Measurement Circuit Using a Simplified Very Small Phase Difference Measurement Circuit
    Noguchi, Takuro
    Fukai, Sumio
    Ishikawa, Yohei
    Shimizu, Akio
    Kimoto, Akira
    Toyoda, Ichihiko
    ELECTRICAL ENGINEERING IN JAPAN, 2018, 203 (01) : 28 - 36
  • [47] New Measurement Analysis for Emotion Detection Using ECG Data
    Dorner, Verena
    Ortiz, Cesar Enrique Uribe
    INFORMATION SYSTEMS AND NEUROSCIENCE, NEUROIS RETREAT 2022, 2022, 58 : 219 - 227
  • [48] EXERCISE ECG ANALYSIS AND MEASUREMENT USING AN EXPERT SYSTEM APPROACH
    FRONING, JN
    OLSON, MD
    FROELICHER, VF
    PROCEEDINGS OF THE ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, PTS 1-4, 1988, : 161 - 162
  • [49] Leg vibrations help cockroaches self-right using wings
    Othayoth, R. S.
    Xuan, Q. H.
    Li, C.
    INTEGRATIVE AND COMPARATIVE BIOLOGY, 2017, 57 : E370 - E370
  • [50] Continuous Cuffless Blood Pressure Measurement using PPG and ECG
    Kusumah, Ilman Himawan
    Setiawan, Agung W.
    2018 INTERNATIONAL SYMPOSIUM ON ELECTRONICS AND SMART DEVICES (ISESD 2018): SMART DEVICES FOR BIG DATA ANALYTIC AND MACHINE LEARNING, 2018, : 1 - 6