Continuous Cuffless Blood Pressure Measurement using PPG and ECG

被引:0
|
作者
Kusumah, Ilman Himawan [1 ]
Setiawan, Agung W. [1 ]
机构
[1] Inst Teknol Bandung, Sch Elect Engn & Informat, Bandung, Indonesia
关键词
Continuous blood pressure; cuffless; PTT; PIR; wearable; ambulatory; clinical standards;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Continuous blood pressure changes monitoring with regular time intervals conventionally is performed by auscultatory and oscillometric measurement techniques. It has limitations on the patient naturality and inconvenience because of repeated arm pumping. This study aims to determine a method of blood pressure measurement that has continuous monitoring, cuffless, wearable and ambulatory measurement features and accuracy of clinical standards. The configuration uses PPG sensor and lead-1 ECG to obtain the PTT and PIR parameter. The parameter used to determine systolic and diastolic blood pressure. Tests performed on 40 healthy subjects in seated, stand and lying down position. The results prototypes have a mean +/- standard deviation (SD) to estimate of systolic, diastolic and pulse pressure were 0.55 +/- 7.42 mmHg, 0.37 +/- 7.20mmHg, 0.08 +/- 10.07mmHg, respectively. The MAD of systolic, diastolic and pulse pressure were 6.02 mmHg, 6.00 mmHg, and 8.03 mmHg, respectively. The highest correlation between estimated and reference blood pressure had Rsquare 0.719 for diastolic and 0.672 for systolic. Regression analysis for each subject between PTT and pulse pressure with highest Rsquare is 0,894 and for PIR and diastole is 0,663.
引用
收藏
页码:1 / 6
页数:6
相关论文
共 50 条
  • [1] Continual Learning for Cuffless Blood Pressure Measurement using PPG and ECG Signals
    Zhang, Chunlin
    Shen, Zhan
    Ding, Xiaorong
    2023 45TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE & BIOLOGY SOCIETY, EMBC, 2023,
  • [2] A novel dynamical approach in continuous cuffless blood pressure estimation based on ECG and PPG signals
    Sharifi, Iman
    Goudarzi, Sobhan
    Khodabakhshi, Mohammad Bagher
    ARTIFICIAL INTELLIGENCE IN MEDICINE, 2019, 97 : 143 - 151
  • [3] Secondary Peak Detection of PPG Signal for Continuous Cuffless Arterial Blood Pressure Measurement
    He, Xiaochuan
    Goubran, Rafik A.
    Liu, Xiaoping P.
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2014, 63 (06) : 1431 - 1439
  • [4] Continuous Peripheral Blood Pressure Measurement with ECG and PPG Signals at Fingertips
    Lee, Kar Mun
    Qian, Zhengyang
    Yabuki, Ryosuke
    Du, Bang
    Kino, Hisashi
    Fukushima, Takafumi
    Kiyoyama, Koji
    Tanaka, Tetsu
    2018 IEEE BIOMEDICAL CIRCUITS AND SYSTEMS CONFERENCE (BIOCAS): ADVANCED SYSTEMS FOR ENHANCING HUMAN HEALTH, 2018, : 471 - 474
  • [5] A continuous cuffless blood pressure measurement from optimal PPG characteristic features using machine learning algorithms
    Nishan, Araf
    Raju, S. M. Taslim Uddin
    Hossain, Md Imran
    Dipto, Safin Ahmed
    Uddin, S. M. Tanvir
    Sijan, Asif
    Chowdhury, Md Abu Shahid
    Ahmad, Ashfaq
    Khan, Md Mahamudul Hasan
    HELIYON, 2024, 10 (06)
  • [6] Continuous Cuffless Blood Pressure Measurement Using Body Sensors
    Heydari, Fatemeh
    Ebrahim, Malikeh P.
    Wu, Taiyang
    Walkert, Katie
    Joe, Keith
    Redoute, Jean-Michel
    Yuce, Mehmet R.
    2018 IEEE SENSORS, 2018, : 180 - 183
  • [7] Cuffless and Continuous Blood Pressure Estimation From PPG Signals Using Recurrent Neural Networks
    El Hajj, Chadi
    Kyriacou, Panayiotis A.
    42ND ANNUAL INTERNATIONAL CONFERENCES OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY: ENABLING INNOVATIVE TECHNOLOGIES FOR GLOBAL HEALTHCARE EMBC'20, 2020, : 4269 - 4272
  • [8] Improvement of blood pressure measurement based on ECG and PPG
    Xu, Jiu-Qiang
    Lin, Hong-Ji
    Li, Han
    Zhao, Hai
    Dongbei Daxue Xuebao/Journal of Northeastern University, 2014, 35 (01): : 33 - 37
  • [9] Advances in Cuffless Continuous Blood Pressure Monitoring Technology Based on PPG Signals
    Qin, Caijie
    Wang, Xiaohua
    Xu, Guangjun
    Ma, Xibo
    BIOMED RESEARCH INTERNATIONAL, 2022, 2022
  • [10] A Cluster Method to Noninvasive Continuous Blood Pressure Measurement Using PPG
    Miao, Yu
    Zhang, Zhiqiang
    Meng, Lifang
    Xie, Xiaoqin
    Pan, Haiwei
    SMART HEALTH, ICSH 2016, 2017, 10219 : 109 - 120