An ECG measurement IC using driven-right-leg circuit

被引:15
|
作者
Wong, Alex [1 ]
Pun, Kong-Pang [1 ]
Zhang, Yuan-Ting [1 ]
Choy, Chiu-Sing [1 ]
机构
[1] Chinese Univ Hong Kong, Dept Elect Engn, Shatin, Hong Kong, Peoples R China
关键词
D O I
10.1109/ISCAS.2006.1692593
中图分类号
TP3 [计算技术、计算机技术];
学科分类号
0812 ;
摘要
In this paper, an electrocardiographic (ECG) signal processing IC, which will be used for portable biomedical application, was designed using continuous-time technique. The circuit consists of an instrumentation amplifier (INA) with driven-right-leg circuit (DRL), a 5(th) order G(m)-C low pass filter (G(m)-C LPF) operating in sub-threshold mode, and amplifiers. DRL circuit is used to detect small amplitude signal in the presence of large common-mode voltage from the human body. The CMRR of the INA is 78 dB and the G(m)-C LPF has a cutoff frequency of 18 Hz. As a result of using the DRL, a small signal can be detected in the presence of large common-mode differential. The circuit consumes 1.23 mW when operating from with a supply voltage of +/- 1.5-V and occupies a core area of 0.94 mm(2). The circuit was designed in a 0.35 mu m CMOS process and simulation results have successfully demonstrated the functionalitics.
引用
收藏
页码:345 / +
页数:2
相关论文
共 50 条
  • [21] ECG DIAGNOSTIC ERRORS DUE TO IMPROPER CONNECTION OF THE RIGHT ARM AND LEG CABLES
    GUIJARROMORALES, A
    GILEXTREMERA, B
    MALDONADOMARTIN, A
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 1991, 30 (02) : 233 - 235
  • [22] Two-Electrode ECG Measurement Circuit Using a Feed Forward CMRR Enhancement Method
    Jedari, Esrafil
    Rashidzadeh, Rashid
    Mirhassani, Mitra
    Ahmadi, Majid
    2017 IEEE 30TH CANADIAN CONFERENCE ON ELECTRICAL AND COMPUTER ENGINEERING (CCECE), 2017,
  • [23] An Integrated Multichannel Neural Recording Analog Front-End ASIC with Area-Efficient Driven Right Leg Circuit
    Tang, Tao
    Goh, Wang Ling
    Yao, Lei
    Hao, Jia
    Gao, Yuan
    2017 39TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2017, : 217 - 220
  • [24] Measurement of body fat using leg to leg bioimpedance
    Sung, RYT
    Lau, P
    Yu, CW
    Lam, PKW
    Nelson, EAS
    ARCHIVES OF DISEASE IN CHILDHOOD, 2001, 85 (03) : 263 - 267
  • [25] To the Contribution Right Leg Block, Left Leg Block, Pacemaker in acute Coronary Syndrome - can one forget the ECG?
    Simon, Andras
    Vamos, Mate
    DEUTSCHE MEDIZINISCHE WOCHENSCHRIFT, 2017, 142 (17) : 1324 - 1325
  • [26] Saturation of the Right-Leg Drive Amplifier in Low-Voltage ECG Monitors
    Freeman, Daniel K.
    Gatzke, Ronald D.
    Mallas, Georgios
    Chen, Yu
    Brouse, Chris J.
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2015, 62 (01) : 323 - 330
  • [27] Power decoupling circuit for modeling and measurement of EMC characteristics of IC/LSI
    Koga, R
    Wada, O
    Toyota, Y
    Miyashita, T
    Fukumoto, Y
    Namba, A
    Takahata, Y
    Kagawa, N
    ASIA-PACIFIC CONFERENCE ON ENVIRONMENTAL ELECTROMAGNETICS: CEEM'2000, PROCEEDINGS, 2000, : 444 - 448
  • [28] To the Contribution Right Leg Block, Left Leg Block, Pacemaker in acute Coronary Syndrome - can one forget the ECG? Reply
    Grautoff, Steffen
    DEUTSCHE MEDIZINISCHE WOCHENSCHRIFT, 2017, 142 (17) : 1326 - 1327
  • [29] A CMOS transponder IC using a new damping circuit
    Oh, WS
    Park, JT
    Yu, CG
    IEICE TRANSACTIONS ON ELECTRONICS, 2002, E85C (06): : 1351 - 1355
  • [30] The ECG measurement in the bathtub using the insulated electrodes
    Lim, YK
    Kim, KK
    Park, KS
    PROCEEDINGS OF THE 26TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2004, 26 : 2383 - 2385