An ECG measurement IC using driven-right-leg circuit

被引:15
|
作者
Wong, Alex [1 ]
Pun, Kong-Pang [1 ]
Zhang, Yuan-Ting [1 ]
Choy, Chiu-Sing [1 ]
机构
[1] Chinese Univ Hong Kong, Dept Elect Engn, Shatin, Hong Kong, Peoples R China
关键词
D O I
10.1109/ISCAS.2006.1692593
中图分类号
TP3 [计算技术、计算机技术];
学科分类号
0812 ;
摘要
In this paper, an electrocardiographic (ECG) signal processing IC, which will be used for portable biomedical application, was designed using continuous-time technique. The circuit consists of an instrumentation amplifier (INA) with driven-right-leg circuit (DRL), a 5(th) order G(m)-C low pass filter (G(m)-C LPF) operating in sub-threshold mode, and amplifiers. DRL circuit is used to detect small amplitude signal in the presence of large common-mode voltage from the human body. The CMRR of the INA is 78 dB and the G(m)-C LPF has a cutoff frequency of 18 Hz. As a result of using the DRL, a small signal can be detected in the presence of large common-mode differential. The circuit consumes 1.23 mW when operating from with a supply voltage of +/- 1.5-V and occupies a core area of 0.94 mm(2). The circuit was designed in a 0.35 mu m CMOS process and simulation results have successfully demonstrated the functionalitics.
引用
收藏
页码:345 / +
页数:2
相关论文
共 50 条
  • [31] Design and Testing of a low-cost Electromyogram that Uses a Right Leg Driver Circuit
    Fortune, Benjamin C.
    Stewart, Ashley
    Hansenne, Eva
    McKenzie, Lachlan
    Chatfield, Logan
    Pretty, Chris G.
    2017 24TH INTERNATIONAL CONFERENCE ON MECHATRONICS AND MACHINE VISION IN PRACTICE (M2VIP), 2017, : 334 - 339
  • [32] THYRISTOR TRIGGER-CIRCUIT USING A 555 IC TIMER
    NEELAKANTAN, VN
    KRISHNAN, A
    INTERNATIONAL JOURNAL OF ELECTRONICS, 1977, 42 (05) : 515 - 517
  • [33] ECG Example: Sinus Tachycardia with incomplete Right-leg Block and ST-range Changes
    Kammler, J.
    JOURNAL FUR KARDIOLOGIE, 2005, 12 (3-4): : 62 - 63
  • [34] ECG Example: Complete Right Leg Block with Signs of the ST-segment Elevation Myocardial Infarction
    Michalski, T.
    Fritsch, G.
    Franz, A.
    Buchner, S.
    JOURNAL FUR KARDIOLOGIE, 2013, 20 (5-6): : 174 - 174
  • [35] Detecting ECG Limb Lead-wire Interchanges Involving the Right Leg Lead-wire
    Gregg, Richard E.
    Hancock, E. William
    Babaeizadeh, Saeed
    2017 COMPUTING IN CARDIOLOGY (CINC), 2017, 44
  • [36] A method of the measurement of moisture in IC packages using microwaves
    Ju, Y
    Saka, M
    Abé, H
    IEEE TRANSACTIONS ON ELECTRONICS PACKAGING MANUFACTURING, 2003, 26 (03): : 228 - 231
  • [37] Model-Driven Analysis of ECG Using Reinforcement Learning
    O'Reilly, Christian
    Oruganti, Sai Durga Rithvik
    Tilwani, Deepa
    Bradshaw, Jessica
    BIOENGINEERING-BASEL, 2023, 10 (06):
  • [38] Measurement of leg fluid volume using bioelectrical impedance
    Singh, Bhajan
    Yadollahi, Azadeh
    Bradley, T.
    FASEB JOURNAL, 2014, 28 (01):
  • [39] Measurement of the volume of a leg ulcer using a laser scanner
    Marjanovic, D
    Dugdale, RE
    Vowden, P
    Vowden, KR
    PHYSIOLOGICAL MEASUREMENT, 1998, 19 (04) : 535 - 543
  • [40] SIMULTANEOUS INTRACARDIAC ECG AND HAEMODYNAMIC MEASUREMENT IN A RIGHT VENTRICULAR TUMOUR CAUSING INFLOW OBSTRUCTION
    YOUSOF, AM
    ENDRYS, J
    STEINHART, L
    ALYOUSOF, AR
    COR ET VASA, 1973, 15 (04) : 306 - 311