Pseudodynamic tests on a full-scale 3-storey precast concrete building: Global response

被引:82
|
作者
Negro, Paolo [1 ]
Bournas, Dionysios A. [2 ]
Molina, Francisco J. [1 ]
机构
[1] Commiss European Communities, Joint Res Ctr, Inst Protect & Secur Citizen, European Lab Struct Assessment, I-21020 Ispra, VA, Italy
[2] Univ Nottingham, Dept Civil Engn, Nottingham NG7 2RD, England
关键词
Precast concrete structures; Pseudodynamic tests; Safecast project; Beam-column joints; Diaphragm; Dry connections; Mechanical connections; Shear walls;
D O I
10.1016/j.engstruct.2013.05.047
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In the framework of the SAFECAST Project, a full-scale three-storey precast building was subjected to a series of pseudodynamic (PsD) tests in the European Laboratory for Structural Assessment (ELSA). The mock-up was constructed in such a way that four different structural configurations could be investigated experimentally. Therefore, the behaviour of various parameters like the types of mechanical connections (traditional as well as innovative) and the presence or absence of shear walls along with the framed structure were investigated. The first PsD tests were conducted on a dual frame-wall precast system, where two precast shear wall units were connected to the mock up. The first test structure sustained the maximum earthquake for which it had been designed with small horizontal deformations. In the second layout, the shear walls were disconnected from the structure, to test the building in its most typical configuration, namely with hinged beam-column connections by means of dowel bars (shear connectors). This configuration was quite flexible and suffered large deformations under the design level earthquake. An innovative connection system, embedded in the precast elements, was then activated to create emulative beam-column connections in the last two structural configurations. In particular, in the third layout the connectors were restrained only at the top floor, whereas in the fourth layout the connection system was activated in all beam-column joints. The PsD test results showed that, when activated at all the floors, the proposed connection system is quite effective as a means of implementing dry precast (quasi) emulative moment-resisting frames. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:594 / 608
页数:15
相关论文
共 50 条
  • [21] Fire behaviour of continuous reinforced concrete slabs in a full-scale multi-storey steel-framed building
    Li, B.
    Dong, Y. -L.
    Zhang, D. -S.
    [J]. FIRE SAFETY JOURNAL, 2015, 71 : 226 - 237
  • [22] Response of sewer concrete pipes rehabilitated by CIPP through full-scale model tests
    Inoue, Y.
    Yoshimura, H.
    Tohda, J.
    Ohsugi, A.
    [J]. PHYSICAL MODELLING IN GEOTECHNICS - 6TH ICPMG '06, VOL 1, 2006, : 735 - +
  • [23] Full-Scale Testing of Three-Sided Precast Concrete Arch Sections
    Marshall, Justin D.
    Anderson, J. Brian
    Meadows, R. Luke
    Jensen, T. Jared
    [J]. JOURNAL OF BRIDGE ENGINEERING, 2014, 19 (12)
  • [25] Fire tests on full-scale FRP reinforced concrete slabs
    Hajiloo, Hamzeh
    Green, Mark F.
    Noel, Martin
    Benichou, Noureddine
    Sultan, Mohamed
    [J]. COMPOSITE STRUCTURES, 2017, 179 : 705 - 719
  • [26] Tests of full-scale continuous reinforced concrete flat slabs
    Sherif, AG
    Dilger, WH
    [J]. ACI STRUCTURAL JOURNAL, 2000, 97 (03) : 455 - 467
  • [27] SHEAR TESTS ON FULL-SCALE PRESTRESSED CONCRETE BOX BEAMS
    ARTHUR, PD
    MAHGOUB, MO
    [J]. PROCEEDINGS OF THE INSTITUTION OF CIVIL ENGINEERS PART 2-RESEARCH AND THEORY, 1975, 59 (SEP): : 535 - 540
  • [28] Shaking Table Study of a Full-Scale Single Storey Confined Brick Masonry Building
    Kazemi, M. T.
    Asl, M. Hoseinzadeh
    Bakhshi, A.
    Rofooei, F. Rahimzadeh
    [J]. SCIENTIA IRANICA TRANSACTION A-CIVIL ENGINEERING, 2010, 17 (03): : 184 - 193
  • [29] Shaking table study of a full-scale single storey confined brick masonry building
    Kazemi, M.T.
    Hoseinzadeh Asl, M.
    Bakhshi, A.
    Rahimzadeh Rofooei, F.
    [J]. Scientia Iranica, 2010, 17 (3 A) : 184 - 193
  • [30] Dynamic Modification and Damage Propagation of a Two-Storey Full-Scale Masonry Building
    Kouris, Leonidas Alexandros S.
    Penna, Andrea
    Magenes, Guido
    [J]. ADVANCES IN CIVIL ENGINEERING, 2019, 2019