Pseudodynamic tests on a full-scale 3-storey precast concrete building: Global response

被引:82
|
作者
Negro, Paolo [1 ]
Bournas, Dionysios A. [2 ]
Molina, Francisco J. [1 ]
机构
[1] Commiss European Communities, Joint Res Ctr, Inst Protect & Secur Citizen, European Lab Struct Assessment, I-21020 Ispra, VA, Italy
[2] Univ Nottingham, Dept Civil Engn, Nottingham NG7 2RD, England
关键词
Precast concrete structures; Pseudodynamic tests; Safecast project; Beam-column joints; Diaphragm; Dry connections; Mechanical connections; Shear walls;
D O I
10.1016/j.engstruct.2013.05.047
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In the framework of the SAFECAST Project, a full-scale three-storey precast building was subjected to a series of pseudodynamic (PsD) tests in the European Laboratory for Structural Assessment (ELSA). The mock-up was constructed in such a way that four different structural configurations could be investigated experimentally. Therefore, the behaviour of various parameters like the types of mechanical connections (traditional as well as innovative) and the presence or absence of shear walls along with the framed structure were investigated. The first PsD tests were conducted on a dual frame-wall precast system, where two precast shear wall units were connected to the mock up. The first test structure sustained the maximum earthquake for which it had been designed with small horizontal deformations. In the second layout, the shear walls were disconnected from the structure, to test the building in its most typical configuration, namely with hinged beam-column connections by means of dowel bars (shear connectors). This configuration was quite flexible and suffered large deformations under the design level earthquake. An innovative connection system, embedded in the precast elements, was then activated to create emulative beam-column connections in the last two structural configurations. In particular, in the third layout the connectors were restrained only at the top floor, whereas in the fourth layout the connection system was activated in all beam-column joints. The PsD test results showed that, when activated at all the floors, the proposed connection system is quite effective as a means of implementing dry precast (quasi) emulative moment-resisting frames. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:594 / 608
页数:15
相关论文
共 50 条
  • [1] Pseudodynamic tests on a full-scale 3-storey precast concrete building: Behavior of the mechanical connections and floor diaphragms
    Bournas, Dionysios A.
    Negro, Paolo
    Molina, Francisco J.
    [J]. ENGINEERING STRUCTURES, 2013, 57 : 609 - 627
  • [2] Preliminary interpretation of shaking-table response of a full-scale 3-storey building composed of thin reinforced concrete sandwich walls
    Palermo, Michele
    Ricci, Ilaria
    Silvestri, Stefano
    Gasparini, Giada
    Trombetti, Tomaso
    Foti, Dora
    Ivorra, Salvador
    [J]. ENGINEERING STRUCTURES, 2014, 76 : 75 - 89
  • [3] Tests on a Full-Scale Precast Building for Robustness Assessment
    Makoond, Nirvan
    Buitrago, Manuel
    Adam, Jose M.
    [J]. STRUCTURES CONGRESS 2023, 2023, : 10 - 20
  • [4] Pseudodynamic tests with substructuring of a full-scale precast box-modularized structure made of reinforced concrete shear walls
    Xu, Guoshan
    Wang, Zhen
    Wu, Bin
    Bursi, Oreste S.
    Tan, Xiaojing
    Yang, Qingbo
    Wen, Long
    Jiang, Hongbin
    [J]. STRUCTURAL DESIGN OF TALL AND SPECIAL BUILDINGS, 2017, 26 (16):
  • [5] Large compartment fire tests on a full-scale eight storey building
    Lennon, T
    [J]. VERY LARGE-SCALE FIRES, 1998, 1336 : 55 - 70
  • [6] Full-scale tests of two-storey precast reinforced concrete shear walls: Investigation of strength and deformation capacity
    Sorensen, Jesper Harrild
    Hoang, Linh Cao
    Poulsen, Peter Noe
    [J]. ENGINEERING STRUCTURES, 2024, 315
  • [7] Precast concrete, L-shaped spandrels revisited: Full-scale tests
    Lucier, Gregory
    Rizkalla, Sarni
    Zia, Paul
    Klein, Gary
    [J]. PCI JOURNAL, 2007, 52 (02): : 62 - 76
  • [8] FULL-SCALE TESTS ON HORIZONTAL JOINTS OF LARGE PANEL PRECAST CONCRETE BUILDINGS
    HARRIS, HG
    IYENGAR, S
    [J]. JOURNAL PRESTRESSED CONCRETE INSTITUTE, 1980, 25 (02): : 72 - 92
  • [9] Full-scale fatigue tests of precast reinforced concrete slabs for railway tracks
    Tarifa, Manuel
    Zhang, XiaoXin
    Ruiz, Gonzalo
    Poveda, Elisa
    [J]. ENGINEERING STRUCTURES, 2015, 100 : 610 - 621
  • [10] Fire tests on two-way concrete, slabs in a full-scale multi-storey steel-framed building
    Yang, Z. N.
    Dong, Y. L.
    Xu, W. J.
    [J]. FIRE SAFETY JOURNAL, 2013, 58 : 38 - 48