Pseudodynamic tests on a full-scale 3-storey precast concrete building: Global response

被引:82
|
作者
Negro, Paolo [1 ]
Bournas, Dionysios A. [2 ]
Molina, Francisco J. [1 ]
机构
[1] Commiss European Communities, Joint Res Ctr, Inst Protect & Secur Citizen, European Lab Struct Assessment, I-21020 Ispra, VA, Italy
[2] Univ Nottingham, Dept Civil Engn, Nottingham NG7 2RD, England
关键词
Precast concrete structures; Pseudodynamic tests; Safecast project; Beam-column joints; Diaphragm; Dry connections; Mechanical connections; Shear walls;
D O I
10.1016/j.engstruct.2013.05.047
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In the framework of the SAFECAST Project, a full-scale three-storey precast building was subjected to a series of pseudodynamic (PsD) tests in the European Laboratory for Structural Assessment (ELSA). The mock-up was constructed in such a way that four different structural configurations could be investigated experimentally. Therefore, the behaviour of various parameters like the types of mechanical connections (traditional as well as innovative) and the presence or absence of shear walls along with the framed structure were investigated. The first PsD tests were conducted on a dual frame-wall precast system, where two precast shear wall units were connected to the mock up. The first test structure sustained the maximum earthquake for which it had been designed with small horizontal deformations. In the second layout, the shear walls were disconnected from the structure, to test the building in its most typical configuration, namely with hinged beam-column connections by means of dowel bars (shear connectors). This configuration was quite flexible and suffered large deformations under the design level earthquake. An innovative connection system, embedded in the precast elements, was then activated to create emulative beam-column connections in the last two structural configurations. In particular, in the third layout the connectors were restrained only at the top floor, whereas in the fourth layout the connection system was activated in all beam-column joints. The PsD test results showed that, when activated at all the floors, the proposed connection system is quite effective as a means of implementing dry precast (quasi) emulative moment-resisting frames. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:594 / 608
页数:15
相关论文
共 50 条
  • [31] Global experimental response of a three-story, full-scale precast concrete shear wall structure with reinforcing bars spliced by grouted couplers
    Han, Wenlong
    Zhao, Zuozhou
    Qian, Jiaru
    [J]. PCI JOURNAL, 2019, 64 (01): : 65 - 80
  • [32] Shaking table tests and seismic assessment of a full-scale precast concrete sandwich wall panel structure with bolt connections
    He, Jia-Xuan
    Xu, Zhao-Dong
    Zhang, Lian-Yu
    Lin, Zhi-Hua
    Hu, Zhong-Wei
    Li, Qiang-Qiang
    Dong, Yao-Rong
    [J]. ENGINEERING STRUCTURES, 2023, 278
  • [33] STRUCTURAL RESPONSE OF FULL-SCALE CONCRETE BOX CULVERT
    ABDELKARIM, AM
    TADROS, MK
    BENAK, JV
    [J]. JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 1993, 119 (11): : 3238 - 3254
  • [34] Dynamic response of a full-scale reinforced concrete building frame retrofitted with FRP column jackets
    Shin, Jiuk
    Scott, David W.
    Stewart, Lauren K.
    Yang, Chuang-Sheng
    Wright, Timothy R.
    DesRoches, Reginald
    [J]. ENGINEERING STRUCTURES, 2016, 125 : 244 - 253
  • [35] Full-scale testing of prefabricated full-depth precast concrete bridge deck panel system
    Issa, Mohsen A.
    Anderson, Ralph
    Domagalski, Thomas
    Asfour, Shaker
    Islam, M. S.
    [J]. ACI STRUCTURAL JOURNAL, 2007, 104 (03) : 324 - 332
  • [36] Numerical analysis of precast tunnel segmental lining supported by full-scale experimental tests
    Cignitti, F.
    Sorge, R.
    Meda, A.
    Nerilli, F.
    Rinaldi, Z.
    [J]. GEOTECHNICAL ASPECTS OF UNDERGROUND CONSTRUCTION IN SOFT GROUND, 7TH INTERNATIONAL SYMPOSIUM, 2012, : 481 - 487
  • [37] Robustness of a full-scale precast building structure subjected to corner-column failure
    Buitrago, Manuel
    Makoond, Nirvan
    Moragues, Juan J.
    Sagaseta, Juan
    Adam, Jose M.
    [J]. STRUCTURES, 2023, 52 : 824 - 841
  • [38] Full-Scale Testing of a Precast Concrete Supertile Roofing System for Hurricane Damage Mitigation
    Mintz, Brandon
    Mirmiran, Amir
    Suksawang, Nakin
    Chowdhury, Arindam Gan
    [J]. JOURNAL OF ARCHITECTURAL ENGINEERING, 2016, 22 (03)
  • [39] Mechanical performance of full-scale precast steel fibre-reinforced concrete pipes
    Mohamed, Nedal
    Soliman, Ahmed M.
    Nehdi, Moncef L.
    [J]. ENGINEERING STRUCTURES, 2015, 84 : 287 - 299
  • [40] Flexural behaviour of full-scale precast recycled concrete sandwich panels with BFRP connectors
    Xie, Jianhe
    Chen, Fangmu
    Zhao, Jianbai
    Lu, Ping
    Liu, Feng
    Li, Lijuan
    [J]. JOURNAL OF BUILDING ENGINEERING, 2022, 56