共 50 条
Fire tests on full-scale FRP reinforced concrete slabs
被引:49
|作者:
Hajiloo, Hamzeh
[1
]
Green, Mark F.
[1
]
Noel, Martin
[2
]
Benichou, Noureddine
[3
]
Sultan, Mohamed
[3
]
机构:
[1] Queens Univ, Civil Engn, 58 Univ Ave, Kingston, ON, Canada
[2] Univ Ottawa, Dept Civil Engn, 161 Louis Pasteur Pvt, Ottawa, ON, Canada
[3] Natl Res Council Canada, NRC Construct, Ottawa, ON, Canada
基金:
加拿大自然科学与工程研究理事会;
关键词:
Fire resistance;
Fibre reinforced polymer;
Concrete slab;
Bond strength;
Numerical analysis;
BEAMS;
D O I:
10.1016/j.compstruct.2017.07.060
中图分类号:
O3 [力学];
学科分类号:
08 ;
0801 ;
摘要:
The fire resistance of two concrete slabs reinforced completely with glass fibre reinforced polymer (GFRP) bars was experimentally investigated through a full-scale standard fire test. The Canadian standard on design of FRP reinforced buildings (CSA S806) currently requires 60 mm of clear concrete cover in a FRP reinforced concrete slab to ensure 2 h of fire resistance. The two concrete slabs, which were identical in every aspect except the types of GFRP reinforcing bars, were designed and fabricated with 60 mm concrete cover in this experiment to examine the fire resistance of the existing FRP reinforced concrete structures designed using CSA S806. The uniformly distributed loads were applied causing flexural moment of 45 kN.m, which was 55% of the ultimate moment resistance of the slabs at room temperatures, and sustained throughout the fire test. Both loaded slabs endured more than three hours of ASTM-E119 standard fire exposure. The results promised a more efficient and economic application of FRP reinforcing bars in concrete construction. The effects of concrete cover, unexposed length in providing adequate anchoring at the ends, and two different types of widely used GFRP reinforcing bar were studied in this research. (C) 2017 Elsevier Ltd. All rights reserved.
引用
收藏
页码:705 / 719
页数:15
相关论文