Fire tests on full-scale FRP reinforced concrete slabs

被引:49
|
作者
Hajiloo, Hamzeh [1 ]
Green, Mark F. [1 ]
Noel, Martin [2 ]
Benichou, Noureddine [3 ]
Sultan, Mohamed [3 ]
机构
[1] Queens Univ, Civil Engn, 58 Univ Ave, Kingston, ON, Canada
[2] Univ Ottawa, Dept Civil Engn, 161 Louis Pasteur Pvt, Ottawa, ON, Canada
[3] Natl Res Council Canada, NRC Construct, Ottawa, ON, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
Fire resistance; Fibre reinforced polymer; Concrete slab; Bond strength; Numerical analysis; BEAMS;
D O I
10.1016/j.compstruct.2017.07.060
中图分类号
O3 [力学];
学科分类号
08 ; 0801 ;
摘要
The fire resistance of two concrete slabs reinforced completely with glass fibre reinforced polymer (GFRP) bars was experimentally investigated through a full-scale standard fire test. The Canadian standard on design of FRP reinforced buildings (CSA S806) currently requires 60 mm of clear concrete cover in a FRP reinforced concrete slab to ensure 2 h of fire resistance. The two concrete slabs, which were identical in every aspect except the types of GFRP reinforcing bars, were designed and fabricated with 60 mm concrete cover in this experiment to examine the fire resistance of the existing FRP reinforced concrete structures designed using CSA S806. The uniformly distributed loads were applied causing flexural moment of 45 kN.m, which was 55% of the ultimate moment resistance of the slabs at room temperatures, and sustained throughout the fire test. Both loaded slabs endured more than three hours of ASTM-E119 standard fire exposure. The results promised a more efficient and economic application of FRP reinforcing bars in concrete construction. The effects of concrete cover, unexposed length in providing adequate anchoring at the ends, and two different types of widely used GFRP reinforcing bar were studied in this research. (C) 2017 Elsevier Ltd. All rights reserved.
引用
下载
收藏
页码:705 / 719
页数:15
相关论文
共 50 条
  • [31] IMPLICATIONS OF RESULTS FROM FULL-SCALE TESTS OF REINFORCED AND PRESTRESSED CONCRETE CONTAINMENTS
    HANSON, NW
    SCHULTZ, DM
    TANG, HT
    NUCLEAR ENGINEERING AND DESIGN, 1989, 117 (01) : 79 - 83
  • [32] Nondestructive Evaluation of Postfire Full-Scale Reinforced Concrete Frames: Field Tests
    Cao, Vui Van
    Nguyen, Vu Nguyen
    Ronagh, Hamid
    Nguyen, Cuong Quoc
    Le, Phuc Ba Nguyen
    Nguyen, Ly Hai
    Nguyen, Hung Manh
    Bui, Ho Van
    JOURNAL OF NONDESTRUCTIVE EVALUATION, 2024, 43 (02)
  • [33] Dynamic response of a full-scale reinforced concrete building frame retrofitted with FRP column jackets
    Shin, Jiuk
    Scott, David W.
    Stewart, Lauren K.
    Yang, Chuang-Sheng
    Wright, Timothy R.
    DesRoches, Reginald
    ENGINEERING STRUCTURES, 2016, 125 : 244 - 253
  • [34] Experimental study on fire resistance of full-scale earthquake damaged reinforced concrete columns
    Wen B.
    Gao J.
    Zhang L.
    Wang L.
    1600, Science Press (41): : 1 - 15
  • [35] Poststrengthening of concrete slabs: Full-scale testing and design recommendations
    Seim, W
    Vasquez, A
    Karbhari, V
    Seible, F
    JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 2003, 129 (06): : 743 - 752
  • [36] Nonlinear analysis of FRP-strengthened reinforced concrete slabs under fire
    Gao, Wan-Yang
    Lu, Zhou-Dao
    Yu, Jiang-Tao
    Harbin Gongye Daxue Xuebao/Journal of Harbin Institute of Technology, 2010, 42 (08): : 1311 - 1316
  • [37] SYSTEMS FOR ANIMAL EXPOSURE IN FULL-SCALE FIRE TESTS
    HILADO, CJ
    CUMMING, HJ
    KOURTIDES, DA
    PARKER, JA
    JOURNAL OF COMBUSTION TOXICOLOGY, 1977, 4 (02): : 101 - 113
  • [38] Impact of elevated temperature on the behavior of full-scale concrete bridge deck slabs reinforced with GFRP bars
    Al-Rousan, Rajai Z.
    STRUCTURES, 2022, 43 : 621 - 634
  • [39] Seismic Retrofit of Joints of a Full-Scale 3D Reinforced Concrete Frame with FRP Composites
    Cosgun, Cumhur
    Comert, Mustafa
    Demir, Cem
    Ilki, Alper
    JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2019, 23 (02)
  • [40] Seismic performance of full-scale reinforced concrete columns
    Bae, Sungjin
    Bayrak, Oguzhan
    ACI STRUCTURAL JOURNAL, 2008, 105 (02) : 123 - 133