Fire tests on full-scale FRP reinforced concrete slabs

被引:49
|
作者
Hajiloo, Hamzeh [1 ]
Green, Mark F. [1 ]
Noel, Martin [2 ]
Benichou, Noureddine [3 ]
Sultan, Mohamed [3 ]
机构
[1] Queens Univ, Civil Engn, 58 Univ Ave, Kingston, ON, Canada
[2] Univ Ottawa, Dept Civil Engn, 161 Louis Pasteur Pvt, Ottawa, ON, Canada
[3] Natl Res Council Canada, NRC Construct, Ottawa, ON, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
Fire resistance; Fibre reinforced polymer; Concrete slab; Bond strength; Numerical analysis; BEAMS;
D O I
10.1016/j.compstruct.2017.07.060
中图分类号
O3 [力学];
学科分类号
08 ; 0801 ;
摘要
The fire resistance of two concrete slabs reinforced completely with glass fibre reinforced polymer (GFRP) bars was experimentally investigated through a full-scale standard fire test. The Canadian standard on design of FRP reinforced buildings (CSA S806) currently requires 60 mm of clear concrete cover in a FRP reinforced concrete slab to ensure 2 h of fire resistance. The two concrete slabs, which were identical in every aspect except the types of GFRP reinforcing bars, were designed and fabricated with 60 mm concrete cover in this experiment to examine the fire resistance of the existing FRP reinforced concrete structures designed using CSA S806. The uniformly distributed loads were applied causing flexural moment of 45 kN.m, which was 55% of the ultimate moment resistance of the slabs at room temperatures, and sustained throughout the fire test. Both loaded slabs endured more than three hours of ASTM-E119 standard fire exposure. The results promised a more efficient and economic application of FRP reinforcing bars in concrete construction. The effects of concrete cover, unexposed length in providing adequate anchoring at the ends, and two different types of widely used GFRP reinforcing bar were studied in this research. (C) 2017 Elsevier Ltd. All rights reserved.
引用
下载
收藏
页码:705 / 719
页数:15
相关论文
共 50 条
  • [41] Structural Failure of Reinforced Concrete Bearing Walls under Fire: A Full-Scale Experimental Investigation
    Mueller, Kevin A.
    Kurama, Yahya C.
    RESPONSE OF STRUCTURES UNDER EXTREME LOADING, 2015, : 677 - 685
  • [42] THE RATIONAL DEVELOPMENT OF BENCH-SCALE FIRE TESTS FOR FULL-SCALE FIRE PREDICTION
    BABRAUSKAS, V
    WICKSTROM, U
    FIRE SAFETY SCIENCE - PROCEEDINGS OF THE SECOND INTERNATIONAL SYMPOSIUM, 1989, : 813 - 822
  • [43] Concrete Slabs Reinforced with FRP or Steel Reinforcements
    Razzaq, Zia
    Dabbagh, Mohamed A. E.
    Sirjani, Mojtaba B.
    Prabhakaran, Ram
    JOURNAL OF REINFORCED PLASTICS AND COMPOSITES, 2009, 28 (09) : 1111 - 1121
  • [44] Arching action in FRP reinforced concrete slabs
    Taylor, SE
    Mullin, B
    CONSTRUCTION AND BUILDING MATERIALS, 2006, 20 (1-2) : 71 - 80
  • [45] Evaluating the fire endurance of concrete slabs reinforced with FRP bars: Considerations for a holistic approach
    Bisby, L. A.
    Kodur, V. K. R.
    COMPOSITES PART B-ENGINEERING, 2007, 38 (5-6) : 547 - 558
  • [46] Experimental behavior of fire-exposed reinforced concrete slabs without and with FRP retrofitting
    Vui Van Cao
    Huy Ba Vo
    Luan Hoai Dinh
    Det Van Doan
    JOURNAL OF BUILDING ENGINEERING, 2022, 51
  • [47] Robustness of Reinforced Concrete Slab Structures: Lessons Learned from Two Full-Scale Tests
    Perez Caldentey, Alejandro
    G. Diego, Yolanda
    Santos, Anastasio P.
    Lopez, Lina
    Chiquito, Maria
    Castedo, Ricardo
    BUILDINGS, 2024, 14 (02)
  • [48] Testing robustness: A full-scale experimental test on a two-storey reinforced concrete frame with solid slabs
    Caldentey, Alejandro Perez
    Diego, Yolanda G.
    Fernandez, Freddy Arinez
    Santos, Anastasio P.
    ENGINEERING STRUCTURES, 2021, 240
  • [49] Full-scale fire tests on steel roof truss structures
    Jiang, Shouchao
    Zhu, Shaojun
    Guo, Xiaonong
    Li, Zhiyuan
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2020, 169
  • [50] FIRE GAS CHARACTERIZATION BY ANIMAL EXPOSURE IN FULL-SCALE TESTS
    MARCUSSEN, WH
    HILADO, CJ
    PROCEEDINGS OF THE WESTERN PHARMACOLOGY SOCIETY, 1976, 19 : 401 - 404