Prosthetic venous valve patient selection by validated physics-based computational models

被引:2
|
作者
Chen, Henry Y. [1 ,2 ,4 ]
Berwick, Zachary C. [2 ,4 ]
Kemp, Arika [1 ]
Krieger, Joshua [5 ]
Chambers, Sean [3 ]
Lurie, Fedor [6 ]
Kassab, Ghassan S. [1 ,3 ,4 ]
机构
[1] IUPUI, Dept Biomed Engn, 635 Barnhill Dr,MS 2065, Indianapolis, IN 46202 USA
[2] Calif Med Innovat Inst Inc, San Diego, CA USA
[3] Indiana Univ Sch Med, Dept Surg, Indianapolis, IN 46202 USA
[4] Indiana Univ Sch Med, Dept Cellular & Integrat Physiol, Indianapolis, IN 46202 USA
[5] Cook Med, Res Engn, Bloomington, IN USA
[6] Jobst Vasc Inst, Toledo, OH USA
关键词
FLOW; ARTERIES;
D O I
10.1016/j.jvsv.2014.07.003
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background: There is significant interest in a venous prosthesis to replace insufficient valves. The aim of the current study was to select the patients with hemodynamic conditions most likely to benefit from a valve implant. The hypothesis is that the venous valve prosthesis is most suitable for patients with significant reflux, such as in chronic venous insufficiency (CVI), right heart hypertrophy (RHH), and right heart failure (RHF). Conversely, a prosthetic valve is likely to be of least benefit for deep venous thrombosis (DVT) patients with low flow. Methods: To address this hypothesis, fully coupled fluid and solid mechanics computational models were developed and validated in five acute canine implants. The animal-validated simulations were then carried out for the CVI, RHH, RHF, and DVT patients based on literature hemodynamic data. A mechanical stress ratio of leaflet wall stress to fluid wall shear stress was defined to combine the effects of both fluid mechanics and solid mechanics on leaflet function, for which a lower stress ratio is hemodynamically desirable. Results: The simulation results of mean valve flow velocity and percentage valve opening were found to be within 10% of the measurements in canines. The simulations show that the patients in the CVI classes 4 to 6, RHH patients, and RHF patients may have a significant reduction in stress ratio with virtual implant of a prosthetic valve. The DVT patient simulations demonstrate a minimal reduction in the stress ratio. After thrombus removal where flow is restored, however, the prosthetic valve may be helpful for post-thrombotic patients. Conclusions: For patient selections of the venous valve prosthesis, the most suitable patients are the CVI classes 4 to 6, RHH, and RHF patients. The least suitable patients are the DVT patients because a valve is not effective under low flow conditions. The present study demonstrates a physics based approach to patient selection that can be tested in future clinical trials.
引用
收藏
页码:75 / 80
页数:6
相关论文
共 50 条
  • [21] Fast neural network surrogates for very high dimensional physics-based models in computational oceanography
    van der Merwe, Rudolph
    Leen, Todd K.
    Lu, Zhengdong
    Frolov, Sergey
    Baptista, Antonio M.
    NEURAL NETWORKS, 2007, 20 (04) : 462 - 478
  • [22] Editorial: Data assimilation in cardiovascular medicine: Merging experimental measurements with physics-based computational models
    Lim, E.
    Shi, Y.
    Leo, H. L.
    Al Abed, A.
    FRONTIERS IN PHYSIOLOGY, 2023, 14
  • [23] Physics-based keyframe selection for human motion summarization
    Athanasios Voulodimos
    Ioannis Rallis
    Nikolaos Doulamis
    Multimedia Tools and Applications, 2020, 79 : 3243 - 3259
  • [24] Motion Generation for Physics-Based Character by Clustering Selection
    Zhang Y.
    Xie W.
    Li S.
    Liu X.
    Jisuanji Fuzhu Sheji Yu Tuxingxue Xuebao/Journal of Computer-Aided Design and Computer Graphics, 2018, 30 (07): : 1258 - 1267
  • [25] Physics-Based Selection of Informative Actions for Interactive Perception
    Eppner, Clemens
    Martin-Martin, Roberto
    Brock, Oliver
    2018 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND AUTOMATION (ICRA), 2018, : 7427 - 7432
  • [26] Physics-based keyframe selection for human motion summarization
    Voulodimos, Athanasios
    Rallis, Ioannis
    Doulamis, Nikolaos
    MULTIMEDIA TOOLS AND APPLICATIONS, 2020, 79 (5-6) : 3243 - 3259
  • [27] Towards a purely physics-based computational binding affinity estimation
    Polasa, Adithya
    Moradi, Mahmoud
    NATURE COMPUTATIONAL SCIENCE, 2023, 3 (01): : 10 - 10
  • [28] The imperative of physics-based modeling and inverse theory in computational science
    Karen E. Willcox
    Omar Ghattas
    Patrick Heimbach
    Nature Computational Science, 2021, 1 : 166 - 168
  • [29] Physics-based computational and theoretical approaches to intrinsically disordered proteins
    Shea, Joan-Emma
    Best, Robert B.
    Mittal, Jeetain
    CURRENT OPINION IN STRUCTURAL BIOLOGY, 2021, 67 : 219 - 225
  • [30] Towards a purely physics-based computational binding affinity estimation
    Nature Computational Science, 2023, 3 : 10 - 11