Prosthetic venous valve patient selection by validated physics-based computational models

被引:2
|
作者
Chen, Henry Y. [1 ,2 ,4 ]
Berwick, Zachary C. [2 ,4 ]
Kemp, Arika [1 ]
Krieger, Joshua [5 ]
Chambers, Sean [3 ]
Lurie, Fedor [6 ]
Kassab, Ghassan S. [1 ,3 ,4 ]
机构
[1] IUPUI, Dept Biomed Engn, 635 Barnhill Dr,MS 2065, Indianapolis, IN 46202 USA
[2] Calif Med Innovat Inst Inc, San Diego, CA USA
[3] Indiana Univ Sch Med, Dept Surg, Indianapolis, IN 46202 USA
[4] Indiana Univ Sch Med, Dept Cellular & Integrat Physiol, Indianapolis, IN 46202 USA
[5] Cook Med, Res Engn, Bloomington, IN USA
[6] Jobst Vasc Inst, Toledo, OH USA
关键词
FLOW; ARTERIES;
D O I
10.1016/j.jvsv.2014.07.003
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background: There is significant interest in a venous prosthesis to replace insufficient valves. The aim of the current study was to select the patients with hemodynamic conditions most likely to benefit from a valve implant. The hypothesis is that the venous valve prosthesis is most suitable for patients with significant reflux, such as in chronic venous insufficiency (CVI), right heart hypertrophy (RHH), and right heart failure (RHF). Conversely, a prosthetic valve is likely to be of least benefit for deep venous thrombosis (DVT) patients with low flow. Methods: To address this hypothesis, fully coupled fluid and solid mechanics computational models were developed and validated in five acute canine implants. The animal-validated simulations were then carried out for the CVI, RHH, RHF, and DVT patients based on literature hemodynamic data. A mechanical stress ratio of leaflet wall stress to fluid wall shear stress was defined to combine the effects of both fluid mechanics and solid mechanics on leaflet function, for which a lower stress ratio is hemodynamically desirable. Results: The simulation results of mean valve flow velocity and percentage valve opening were found to be within 10% of the measurements in canines. The simulations show that the patients in the CVI classes 4 to 6, RHH patients, and RHF patients may have a significant reduction in stress ratio with virtual implant of a prosthetic valve. The DVT patient simulations demonstrate a minimal reduction in the stress ratio. After thrombus removal where flow is restored, however, the prosthetic valve may be helpful for post-thrombotic patients. Conclusions: For patient selections of the venous valve prosthesis, the most suitable patients are the CVI classes 4 to 6, RHH, and RHF patients. The least suitable patients are the DVT patients because a valve is not effective under low flow conditions. The present study demonstrates a physics based approach to patient selection that can be tested in future clinical trials.
引用
收藏
页码:75 / 80
页数:6
相关论文
共 50 条
  • [31] The imperative of physics-based modeling and inverse theory in computational science
    Willcox, Karen E.
    Ghattas, Omar
    Heimbach, Patrick
    NATURE COMPUTATIONAL SCIENCE, 2021, 1 (03): : 166 - 168
  • [32] CHALLENGES FOR PHYSICS-BASED MODELS OF A RADIONUCLIDE DISPERSAL DEVICE
    Hummel, David William
    Ivan, Lucian
    CNL NUCLEAR REVIEW, 2019, 8 (01) : 83 - 85
  • [33] Snake pedals: Geometric models with physics-based control
    Vemuri, BC
    Guo, Y
    SIXTH INTERNATIONAL CONFERENCE ON COMPUTER VISION, 1998, : 427 - 432
  • [34] Reconciling the understanding of 'hydrophobicity' with physics-based models of proteins
    Harris, Robert C.
    Pettitt, B. Montgomery
    JOURNAL OF PHYSICS-CONDENSED MATTER, 2016, 28 (08)
  • [35] Physics-based simulation models for EBSD: advances and challenges
    Winkelmann, A.
    Nolze, G.
    Vos, M.
    Salvat-Pujol, F.
    Werner, W. S. M.
    14TH EUROPEAN WORKSHOP ON MODERN DEVELOPMENTS AND APPLICATIONS IN MICROBEAM ANALYSIS (EMAS 2015 WORKSHOP), 2016, 109
  • [36] Physics-based secular variation candidate models for the IGRF
    Alexandre Fournier
    Julien Aubert
    Vincent Lesur
    Erwan Thébault
    Earth, Planets and Space, 73
  • [37] Nonlinear sparse Bayesian learning for physics-based models
    Sandhu, Rimple
    Khalil, Mohammad
    Pettit, Chris
    Poirel, Dominique
    Sarkar, Abhijit
    JOURNAL OF COMPUTATIONAL PHYSICS, 2021, 426
  • [38] Invertible Physics-Based Hyperspectral Signature Models: A review
    Al Hayek, Marianne
    Baskiotis, Catherine
    Aval, Josselin
    Elbouz, Marwa
    El Hassan, Bachar
    IEEE GEOSCIENCE AND REMOTE SENSING MAGAZINE, 2023, 11 (04) : 45 - 62
  • [39] Physics-Based Hot-Carrier Degradation Models
    Tyaginov, S. E.
    Starkov, I. A.
    Enichlmair, H.
    Park, J. M.
    Jungemann, Ch.
    Grasser, T.
    SILICON NITRIDE, SILICON DIOXIDE, AND EMERGING DIELECTRICS 11, 2011, 35 (04): : 321 - 352
  • [40] Derivation of physics-based HRR moving target models
    Ma, JS
    Ahalt, SC
    SIGNAL PROCESSING, SENSOR FUSION, AND TARGET RECOGNITION IX, 2000, 4052 : 78 - 84