Extraction of pacemaker and implantable cardioverter defibrillator leads: Patient and lead characteristics in relation to the requirement of extraction tools

被引:73
|
作者
Bracke, F [1 ]
Meijer, A [1 ]
Van Gelder, B [1 ]
机构
[1] Catharina Hosp, Dept Cardiol, NL-5602 ZA Eindhoven, Netherlands
来源
关键词
lead extraction; technique; laser; pacemaker; implantable defibrillator;
D O I
10.1046/j.1460-9592.2002.01037.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Effective tools for extraction of pacemaker and ICD leads have been developed in the past decennium. This study investigated the necessity of using these tools in addition to direct traction in relation to patient and lead characteristics. The study encompasses first attempts at extraction of consecutive pacemaker and ICD leads from the subpectoral area. A stepwise extraction protocol was used with traction first (directly or with a locking stylet) followed by laser sheath extraction if not successful, The indication, patient age, time from implant, fixation mechanism, location, and insertion site of the leads were studied in relation to the outcome of traction. A total of 145 leads in 83 patients were extracted. Leads were implanted for 71 +/- 61 months. Indication for extraction was infection in 96 leads and malfunction in 49 leads. There were 90 ventricular leads including 16 ICD leads. Forty-nine (34%) leads were extracted with traction; in 96 (66%) leads a laser sheath was necessary. All leads implanted for < 6 months could be removed with traction alone. In a multivariate logistic regression model, time from implant was the main factor determining success of traction (P < 0.001), but in case of infection the success rate increased (P = 0.004). In conclusion, time from implant is the decisive factor to judge the potential efficacy of lead extraction with direct traction, If leads are implanted for 6 months, the availability of additional extraction tools is necessary when lead extraction is considered. In addition to time from implant, infected leads have a better chance to be removed with traction although it is a much weaker predictor.
引用
收藏
页码:1037 / 1040
页数:4
相关论文
共 50 条
  • [41] Transvenous extraction of pacemaker and implantable cardioverter defibrillator leads using Evolution® mechanical dilator sheath: a single center confirmatory experience
    Kocabas, Ugur
    Duygu, Hamza
    Eren, Nihan Kahya
    Akyildiz, Zehra Ilke
    Ozyildirim, Serhan
    Tuluce, Selcen Yakar
    Kiris, Tuncay
    Nazli, Cem
    SPRINGERPLUS, 2016, 5
  • [42] Percutaneous extraction of cardiac pacemaker and implantable cardioverter defibrillator leads with evolution mechanical dilator sheath: a single-centre experience
    Oto, Ali
    Aytemir, Kudret
    Yorgun, Hikmet
    Canpolat, Ugur
    Kaya, Ergun Baris
    Kabakci, Giray
    Tokgozoglu, Lale
    Ozkutlu, Hilmi
    EUROPACE, 2011, 13 (04): : 543 - 547
  • [43] Extraction outcomes of implantable cardioverter-defibrillator leads vary by manufacturer and model family
    Hayashi, Katsuhide
    Callahan, Thomas
    Rickard, John
    Younis, Arwa
    Baranowski, Bryan
    Martin, David
    Nakhla, Shady
    Tabaja, Chadi
    Wilkoff, Bruce L.
    EUROPACE, 2023, 25 (12):
  • [44] TRANSVENOUS EXTRACTION OF CARDIAC PACEMAKER AND IMPLANTABLE CARDIOVERTER DEFIBRILLATOR LEADS WITH EVOLUTION MECHANICAL DILATOR SHEATH: SINGLE-CENTRE EXPERIENCE
    Oto, A.
    Aytemir, K.
    Yorgun, H.
    Canpolat, U.
    Ates, A. H.
    Sunman, H.
    Ulgen, A.
    Sahiner, L.
    Kaya, E. B.
    Kabakci, G.
    Tokgozoglu, L.
    Ozkutlu, H.
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2011, 147 : S81 - S82
  • [45] Safety and efficacy of internal transjugular approach for transvenous extraction of implantable cardioverter defibrillator leads
    Bongiorni, Maria Grazia
    Segreti, Luca
    Di Cori, Andrea
    Zucchelli, Giulio
    Viani, Stefano
    Paperini, Luca
    De Lucia, Raffaele
    Boem, Adriano
    Levorato, Dianora
    Soldati, Ezio
    EUROPACE, 2014, 16 (09): : 1356 - 1362
  • [46] Pacemaker/implantable cardioverter-defibrillator problem: Right ventricular lead missensing in a biventricular implantable cardioverter-defibrillator
    Otten, Richard F.
    Foreman, Lynne D.
    Groh, William J.
    HEART RHYTHM, 2008, 5 (01) : 158 - 159
  • [47] Transvenous extraction of advisory implantable cardioverter defibrillator leads with a relatively long implant duration
    Goya, Masahiko
    Nagashima, Michio
    Hiroshima, Ken-ichi
    Hayashi, Kentaro
    Makihara, Yu
    Fukunaga, Masato
    An, Yoshimori
    Ohe, Masatsugu
    Sasaki, Takeshi
    Shiohira, Shinya
    Shirai, Yasuhiro
    Kawabata, Mihoko
    Ando, Kenji
    Isobe, Mitsuaki
    Hirao, Kenzo
    JOURNAL OF CARDIOLOGY, 2018, 72 (3-4) : 316 - 320
  • [48] Comparison of outcomes and required tools between transvenous extraction of pacemaker and implantable cardioverter defibrillator leads: Insight from single high-volume center experience
    Hayashi, Katsuhide
    Callahan, Thomas
    Rickard, John
    Baranowski, Bryan
    Martin, David O.
    Nakhla, Shady
    Tabaja, Chadi
    Paul, Aritra
    Wilkoff, Bruce L.
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2024, 35 (07) : 1382 - 1392
  • [49] Excimer laser extraction of pacemaker and defibrillator leads
    Nägele, H
    Ismail, M
    Rödiger, W
    ZEITSCHRIFT FUR KARDIOLOGIE, 2001, 90 (08): : 550 - 556
  • [50] Ancillary tools in pacemaker and defibrillator lead extraction using a novel lead removal system
    Manolis, AS
    Maounis, TN
    Vassilikos, V
    Chiladakis, J
    Melita-Manolis, H
    Cokkinos, DV
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2001, 24 (03): : 282 - 287