Extraction of pacemaker and implantable cardioverter defibrillator leads: Patient and lead characteristics in relation to the requirement of extraction tools

被引:73
|
作者
Bracke, F [1 ]
Meijer, A [1 ]
Van Gelder, B [1 ]
机构
[1] Catharina Hosp, Dept Cardiol, NL-5602 ZA Eindhoven, Netherlands
来源
关键词
lead extraction; technique; laser; pacemaker; implantable defibrillator;
D O I
10.1046/j.1460-9592.2002.01037.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Effective tools for extraction of pacemaker and ICD leads have been developed in the past decennium. This study investigated the necessity of using these tools in addition to direct traction in relation to patient and lead characteristics. The study encompasses first attempts at extraction of consecutive pacemaker and ICD leads from the subpectoral area. A stepwise extraction protocol was used with traction first (directly or with a locking stylet) followed by laser sheath extraction if not successful, The indication, patient age, time from implant, fixation mechanism, location, and insertion site of the leads were studied in relation to the outcome of traction. A total of 145 leads in 83 patients were extracted. Leads were implanted for 71 +/- 61 months. Indication for extraction was infection in 96 leads and malfunction in 49 leads. There were 90 ventricular leads including 16 ICD leads. Forty-nine (34%) leads were extracted with traction; in 96 (66%) leads a laser sheath was necessary. All leads implanted for < 6 months could be removed with traction alone. In a multivariate logistic regression model, time from implant was the main factor determining success of traction (P < 0.001), but in case of infection the success rate increased (P = 0.004). In conclusion, time from implant is the decisive factor to judge the potential efficacy of lead extraction with direct traction, If leads are implanted for 6 months, the availability of additional extraction tools is necessary when lead extraction is considered. In addition to time from implant, infected leads have a better chance to be removed with traction although it is a much weaker predictor.
引用
收藏
页码:1037 / 1040
页数:4
相关论文
共 50 条
  • [31] Care of the pacemaker/implantable cardioverter defibrillator patient in the ED
    McMullan, Jason
    Valento, Matthew
    Attari, Mehran
    Venkat, Arvind
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2007, 25 (07): : 812 - 822
  • [32] Pacemaker and Internal Cardioverter Defibrillator Lead Extraction: A Safe and Effective Surgical Approach
    Kratz, John M.
    Toole, John M.
    ANNALS OF THORACIC SURGERY, 2010, 90 (05): : 1411 - 1417
  • [33] Patient characteristics, predictors and outcome of pacemaker patients upgraded to an implantable cardioverter defibrillator
    Baldinger, Samuel H.
    Burren, Desiree
    Noti, Fabian
    Servatius, Helge
    Seiler, Jens
    Madaffari, Antonio
    Asatryan, Babken
    Tanner, Hildegard
    Reichlin, Tobias
    Haeberlin, Andreas
    Roten, Laurent
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2024, 47 (06): : 853 - 861
  • [34] Multicenter Experience With Extraction of the Sprint Fidelis Implantable Cardioverter-Defibrillator Lead
    Martin, David T.
    Hook, Bruce G.
    Chaudhry, G. Muqtada
    Silver, Jonathan
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2011, 57 (05) : 635 - 636
  • [35] A novel indication for transvenous lead extraction: Upgrading implantable cardioverter defibrillator systems
    Korley, VJ
    Hallet, N
    Daoust, M
    Epstein, LM
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2000, 4 (03) : 523 - 528
  • [36] A novel indication for transvenous lead extraction: Upgrading implantable cardioverter defibrillator systems
    Korley V.J.
    Hallet N.
    Daoust M.
    Epstein L.M.
    Journal of Interventional Cardiac Electrophysiology, 2000, 4 (3) : 523 - 528
  • [37] Multicenter Experience With Extraction of the Sprint Fidelis Implantable Cardioverter-Defibrillator Lead
    Maytin, Melanie
    Love, Charles J.
    Fischer, Avi
    Carrillo, Roger G.
    Garisto, Juan D.
    Bongiorni, Maria Grazia
    Segreti, Luca
    John, Roy M.
    Michaud, Gregory F.
    Albert, Christine M.
    Epstein, Laurence M.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2010, 56 (08) : 646 - 650
  • [38] Thoracic paravertebral block for implantable cardioverter-defibrillator and laser lead extraction
    Tsai, Tony
    Rodriguez-Diaz, Cesar
    Deschner, Bonnie
    Thomas, Kurian
    Wasnick, John D.
    JOURNAL OF CLINICAL ANESTHESIA, 2008, 20 (05) : 379 - 382
  • [39] Percutaneous Pacemaker and Implantable Cardioverter-Defibrillator Lead Extraction in 100 Patients With Intracardiac Vegetations Defined by Transesophageal Echocardiogram
    Grammes, Jon A.
    Schulze, Christopher M.
    Al-Bataineh, Mohammad
    Yesenosky, George A.
    Saari, Christine S.
    Vrabel, Michelle J.
    Horrow, Jay
    Chowdhury, Mashiul
    Fontaine, John M.
    Kutalek, Steven P.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2010, 55 (09) : 886 - 894
  • [40] Safety and effectiveness of transvenous extraction of pacemaker and implantable cardioverter-defibrillator leads in patients under or over 80 years of age
    Kempa, Maciej
    Budrejko, Szymon
    Piepiorka, Marta
    Rogowski, Jan
    Raczak, Grzegorz
    Kozlowski, Dariusz
    KARDIOLOGIA POLSKA, 2013, 71 (02) : 130 - 135