Percutaneous extraction of cardiac pacemaker and implantable cardioverter defibrillator leads with evolution mechanical dilator sheath: a single-centre experience

被引:36
|
作者
Oto, Ali [1 ]
Aytemir, Kudret [1 ]
Yorgun, Hikmet [1 ]
Canpolat, Ugur [1 ]
Kaya, Ergun Baris [1 ]
Kabakci, Giray [1 ]
Tokgozoglu, Lale [1 ]
Ozkutlu, Hilmi [1 ]
机构
[1] Hacettepe Univ, Fac Med, Dept Cardiol, TR-06100 Ankara, Turkey
来源
EUROPACE | 2011年 / 13卷 / 04期
关键词
Evolution mechanical sheath; Percutaneous lead extraction; TRANSVENOUS PACEMAKER; INITIAL-EXPERIENCE; INFECTIONS; MANAGEMENT; TRIAL;
D O I
10.1093/europace/euq400
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims The growing problem with endocardial lead infections and lead malfunctions has increased the interest in percutaneous lead removal technology. In this report, we present our initial experience in percutaneous lead extraction with a novel hand-powered sheath, the Evolution mechanical dilator sheath. Methods and results During 13 months between June 2009 and July 2010, 41 leads in 23 patients were removed. All of the extracted leads were >12 months old, and indications for extraction were based on the recommendations of the Heart Rhythm Society. The leads were removed by using the Evolution mechanical dilator sheath (Cook Medical) with the rotational cutting force only, without laser or radiofrequency energy. Indications for lead removal included cardiac device infection in 7 (30.4%) cases, lead malfunction in the 15 (65.2%) cases, and lead displacement in the remaining 1 case (4.4%). In 14 (60.9%) cases, the extracted device was a pacemaker, and implantable cardioverter defibrillators (ICD) in 9 (39.1%) of them. Among 41 leads, 25 (60.9%) were right ventricular, 14 (34%) were atrial, and 2 (4.8%) were coronary sinus electrode. The median time from the preceding procedure was 74 months (25-180 months). Complete procedural success with Evolution system alone was achieved in 19 (82%) patients (35 leads). Four leads were completely removed with snaring and in two leads, partial success was achieved with a remaining ventricular tip smaller than 1.5 cm. Clinical success was 100%, and all of the patients discharged uneventfully without a major complication. Conclusions Our experience confirms that the mechanical technique with Evolution system is an effective first-line method for chronically implanted pacemaker/ICD leads. Continued investigation is required to evaluate success and complication rates in comparison with other techniques.
引用
收藏
页码:543 / 547
页数:5
相关论文
共 50 条
  • [1] TRANSVENOUS EXTRACTION OF CARDIAC PACEMAKER AND IMPLANTABLE CARDIOVERTER DEFIBRILLATOR LEADS WITH EVOLUTION MECHANICAL DILATOR SHEATH: SINGLE-CENTRE EXPERIENCE
    Oto, A.
    Aytemir, K.
    Yorgun, H.
    Canpolat, U.
    Ates, A. H.
    Sunman, H.
    Ulgen, A.
    Sahiner, L.
    Kaya, E. B.
    Kabakci, G.
    Tokgozoglu, L.
    Ozkutlu, H.
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2011, 147 : S81 - S82
  • [2] Evolution in Transvenous Extraction of Pacemaker and Implantable Cardioverter Defibrillator Leads Using a Mechanical Dilator Sheath
    Oto, Ali
    Aytemir, Kudret
    Canpolat, Ugur
    Yorgun, Hikmet
    Sahiner, Levent
    Kaya, Ergun Baris
    Kabakci, Giray
    Tokgozoglu, Lale
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2012, 35 (07): : 834 - 840
  • [3] Transvenous extraction of pacemaker and implantable cardioverter defibrillator leads using Evolution® mechanical dilator sheath: a single center confirmatory experience
    Kocabas, Ugur
    Duygu, Hamza
    Eren, Nihan Kahya
    Akyildiz, Zehra Ilke
    Ozyildirim, Serhan
    Tuluce, Selcen Yakar
    Kiris, Tuncay
    Nazli, Cem
    SPRINGERPLUS, 2016, 5
  • [4] Extraction of pacemaker and implantable cardioverter defibrillator leads: a single-centre study of electrosurgical and laser extraction
    Scott, Paul A.
    Chow, Whitney
    Ellis, Elizabeth
    Morgan, John M.
    Roberts, Paul R.
    EUROPACE, 2009, 11 (11): : 1501 - 1504
  • [5] PERCUTANEOUS EXTRACTION OF CARDIAC PACEMAKER AND IMPLANTABLE CARDIOVERTER DEFIBRILLATOR LEADS WITH A NEW TOOL; A SINGLE CENTER EXPERIENCE
    Oto, Ali
    Aytemir, Kudret
    Kabakci, Giray
    Yorgun, Hikmet
    Canpolat, Ugur
    Kaya, Ergun Baris
    Ates, Ahmet Hakan
    Dural, Muhammet
    Sunman, Hamza
    Evranos, Banu
    Ulgen, Aysegul
    Ozkutlu, Hilmi
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2010, 140 : S83 - S83
  • [6] SINGLE CENTRE EXPERIENCE WITH SEVERAL METHODS FOR EXTRACTION OF PERMANENT PACEMAKER AND IMPLANTABLE CARDIOVERTER DEFIBRILLATOR LEADS
    Oto, A.
    Aytemir, K.
    Yorgun, H.
    Canpolat, U.
    Ates, A. H.
    Sunman, H.
    Ulgen, A.
    Gurses, K. M.
    Kaya, E. B.
    Tokgozoglu, L.
    Kabakci, G.
    Ozkutlu, H.
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2011, 147 : S81 - S81
  • [7] Comparison between percutaneous extraction of implantable cardioverter defibrillator leads and pacemaker leads
    Klug, D.
    Marquie, C.
    Brigadeau, F.
    Guedon, L.
    Kouakam, C.
    Lacroix, D.
    Kacet, S.
    EUROPEAN HEART JOURNAL, 2008, 29 : 397 - 397
  • [8] Extraction of pacemaker and implantable cardioverter defibrillator leads
    Kantharia, BK
    Kutalek, SP
    CURRENT OPINION IN CARDIOLOGY, 1999, 14 (01) : 44 - 51
  • [9] Pacemaker/defibrillator leads extraction: a single centre experience
    Golzio, P-G.
    Vinci, M.
    Pelissero, E.
    Fanelli, A.
    Ferraris, F.
    Gaita, F.
    EUROPEAN HEART JOURNAL, 2012, 33 : 13 - 13
  • [10] Transvenous extraction of pacing and defibrillator leads - a single-centre experience
    Geselle, Pieter-Jan
    Poesen, Ruben
    Rega, Filip
    Koopman, Pieter
    Nuyens, Dieter
    Heidbuchel, Hein
    Willems, Rik
    ACTA CARDIOLOGICA, 2012, 67 (06) : 641 - 648