Percutaneous extraction of cardiac pacemaker and implantable cardioverter defibrillator leads with evolution mechanical dilator sheath: a single-centre experience

被引:36
|
作者
Oto, Ali [1 ]
Aytemir, Kudret [1 ]
Yorgun, Hikmet [1 ]
Canpolat, Ugur [1 ]
Kaya, Ergun Baris [1 ]
Kabakci, Giray [1 ]
Tokgozoglu, Lale [1 ]
Ozkutlu, Hilmi [1 ]
机构
[1] Hacettepe Univ, Fac Med, Dept Cardiol, TR-06100 Ankara, Turkey
来源
EUROPACE | 2011年 / 13卷 / 04期
关键词
Evolution mechanical sheath; Percutaneous lead extraction; TRANSVENOUS PACEMAKER; INITIAL-EXPERIENCE; INFECTIONS; MANAGEMENT; TRIAL;
D O I
10.1093/europace/euq400
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims The growing problem with endocardial lead infections and lead malfunctions has increased the interest in percutaneous lead removal technology. In this report, we present our initial experience in percutaneous lead extraction with a novel hand-powered sheath, the Evolution mechanical dilator sheath. Methods and results During 13 months between June 2009 and July 2010, 41 leads in 23 patients were removed. All of the extracted leads were >12 months old, and indications for extraction were based on the recommendations of the Heart Rhythm Society. The leads were removed by using the Evolution mechanical dilator sheath (Cook Medical) with the rotational cutting force only, without laser or radiofrequency energy. Indications for lead removal included cardiac device infection in 7 (30.4%) cases, lead malfunction in the 15 (65.2%) cases, and lead displacement in the remaining 1 case (4.4%). In 14 (60.9%) cases, the extracted device was a pacemaker, and implantable cardioverter defibrillators (ICD) in 9 (39.1%) of them. Among 41 leads, 25 (60.9%) were right ventricular, 14 (34%) were atrial, and 2 (4.8%) were coronary sinus electrode. The median time from the preceding procedure was 74 months (25-180 months). Complete procedural success with Evolution system alone was achieved in 19 (82%) patients (35 leads). Four leads were completely removed with snaring and in two leads, partial success was achieved with a remaining ventricular tip smaller than 1.5 cm. Clinical success was 100%, and all of the patients discharged uneventfully without a major complication. Conclusions Our experience confirms that the mechanical technique with Evolution system is an effective first-line method for chronically implanted pacemaker/ICD leads. Continued investigation is required to evaluate success and complication rates in comparison with other techniques.
引用
收藏
页码:543 / 547
页数:5
相关论文
共 50 条
  • [31] Comparison of outcomes and required tools between transvenous extraction of pacemaker and implantable cardioverter defibrillator leads: Insight from single high-volume center experience
    Hayashi, Katsuhide
    Callahan, Thomas
    Rickard, John
    Baranowski, Bryan
    Martin, David O.
    Nakhla, Shady
    Tabaja, Chadi
    Paul, Aritra
    Wilkoff, Bruce L.
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2024, 35 (07) : 1382 - 1392
  • [32] Percutaneous leads extraction using mechanical system in 188 patients - single centre experience
    Kutarski, A.
    Malecka, B.
    Rucinski, P.
    Zabek, A.
    EUROPEAN HEART JOURNAL, 2009, 30 : 394 - 394
  • [33] Initial experience with the Evolution mechanical dilator sheath for lead extraction: Safety and efficacy
    Hussein, Ayman A.
    Wilkoff, Bruce L.
    Martin, David O.
    Karim, Saima
    Kanj, Mohamed
    Callahan, Thomas
    Baranowski, Bryan
    Saliba, Walid I.
    Wazni, Oussama M.
    HEART RHYTHM, 2010, 7 (07) : 870 - 873
  • [34] Is metal artefact reduction mandatory in cardiac PET/CT imaging in the presence of pacemaker and implantable cardioverter defibrillator leads?
    Ghafarian, Pardis
    Aghamiri, S. M. R.
    Ay, Mohammad R.
    Rahmim, Arman
    Schindler, Thomas H.
    Ratib, Osman
    Zaidi, Habib
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2011, 38 (02) : 252 - 262
  • [35] Is correction for metallic artefacts mandatory in cardiac SPECT/CT imaging in the presence of pacemaker and implantable cardioverter defibrillator leads?
    Etemadi, Zahra
    Ghafarian, Pardis
    Bitarafan-Rajabi, Ahmad
    Malek, Hadi
    Rahmim, Arman
    Ay, Mohammad Reza
    IRANIAN JOURNAL OF NUCLEAR MEDICINE, 2018, 26 (01): : 35 - 46
  • [36] Is metal artefact reduction mandatory in cardiac PET/CT imaging in the presence of pacemaker and implantable cardioverter defibrillator leads?
    Pardis Ghafarian
    S. M. R. Aghamiri
    Mohammad R. Ay
    Arman Rahmim
    Thomas H. Schindler
    Osman Ratib
    Habib Zaidi
    European Journal of Nuclear Medicine and Molecular Imaging, 2011, 38 : 252 - 262
  • [37] Feasibility, safety, and determinants of extraction time of percutaneous extraction of endocardial implantable cardioverter defibrillator leads by intravascular countertracion method
    Kantharia, BK
    Padder, FA
    Pennington, JC
    Wilbur, SL
    Samuels, FL
    Maquilan, M
    Kutalek, SP
    AMERICAN JOURNAL OF CARDIOLOGY, 2000, 85 (05): : 593 - 597
  • [38] Mechanical extraction of implantable cardioverter-defibrillator leads with a dwell time of more than 10 years: insights from a single high-volume centre
    Zabek, Andrzej
    Boczar, Krzysztof
    Ulman, Mateusz
    Holcman, Katarzyna
    Kostkiewicz, Magdalena
    Pfitzner, Roman
    Debski, Maciej
    Musial, Robert
    Lelakowski, Jacek
    Malecka, Barbara
    EUROPACE, 2023, 25 (03): : 1100 - 1109
  • [39] Subcutaneous implantable cardioverter-defibrillator: is it ready for use in children and young adults? A single-centre study
    Silvetti, Massimo Stefano
    Pazzano, Vincenzo
    Verticelli, Letizia
    Battipaglia, Irma
    Saputo, Fabio Anselmo
    Albanese, Sonia
    Lovecchio, Mariolina
    Valsecchi, Sergio
    Drago, Fabrizio
    EUROPACE, 2018, 20 (12): : 1966 - 1973
  • [40] Implantable Cardioverter Defibrillator Therapy in Cardiac Amyloidosis: An Update of a Single-Center Experience
    Rosenblatt, Anna
    Chuzi, Sarah
    Shah, Sanjiv
    Ghafourian, Kambiz
    Arora, Rishi
    Kim, Susan S.
    Lin, Albert C.
    Verma, Nishant
    Passman, Rod S.
    Knight, Bradley P.
    Chicos, Alexandru
    CIRCULATION, 2018, 138