Start-Up and dynamic processes simulation of supercritical once-through boiler

被引:37
|
作者
Deng, Kangjie [1 ,2 ]
Yang, Chen [1 ,2 ]
Chen, Hao [1 ,2 ]
Zhou, Nana [1 ,2 ]
Huang, Shanglong [1 ,2 ]
机构
[1] Chongqing Univ, Minist Educ, Key Lab Lowgrade Energy Utilizat Technol & Syst, Chongqing 400030, Peoples R China
[2] Chongqing Univ, Coll Power Engn, 174 Shazhengjie, Chongqing 400030, Peoples R China
关键词
Supercritical; Boiler; Cold start-up; Dynamic; Fuel consumption; POWER-PLANT; COAL; VALIDATION; SYSTEM; MODEL;
D O I
10.1016/j.applthermaleng.2017.01.016
中图分类号
O414.1 [热力学];
学科分类号
摘要
The rapid expansion of the electricity demand causes the gap between the peak load and valley load increasing in China. Since the coal-fired supercritical power plant needs to be started up frequently, the operations of power plant become more flexible. During the start-up process, the operation parameters are off-designed, the multi-transient phenomenon is inevitable and the intensive emission always appears during varying working condition, it is difficult to ensure the operator of the real power plant to start up the boiler following the design curve. In this work, a new dynamic model for simulating start-up dynamic process of a 600 MW supercritical boiler is introduced in this paper. The six-equation solution of two-phase flow was applied to modeling the evaporator, and the process from ignition to the load at 30% Boiler Maximum Continuous Rating (BMCR) was simulated. The results demonstrate that the model is reasonable and dynamic behavior can be observed clearly. Also, these prove that the control strategy is advisable. Moreover, the fuel consumption of the start-up process can offer a reference to operator of the real power plant. The validated model is of high relevance for further optimizing the boiler start-up process. (C) 2017 Elsevier Ltd. All rights reserved.
引用
收藏
页码:937 / 946
页数:10
相关论文
共 50 条
  • [31] ONCE-THROUGH BOILER CONTROL
    KENNY, PL
    POWER ENGINEERING, 1968, 72 (01) : 36 - &
  • [32] ONCE-THROUGH BOILER CONTROL
    KENNY, PL
    POWER ENGINEERING, 1968, 72 (02) : 58 - &
  • [33] A dynamic model for supercritical once-through circulating fluidized bed boiler-turbine units
    Zhang, Hongfu
    Gao, Mingming
    Fan, Haohao
    Zhang, Kaiping
    Zhang, Jiahui
    ENERGY, 2022, 241
  • [34] CONTROLS FOR A ONCE-THROUGH BOILER
    LOUIS, JR
    INSTRUMENTS & CONTROL SYSTEMS, 1971, 44 (01): : 77 - &
  • [36] Overheating prediction of evaporating tubes in supercritical pressure once-through boiler
    Liu, Fuguo
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2010, 30 (35): : 18 - 25
  • [37] CALCULATION OF DYNAMIC CHARACTERISTICS OF A ONCE-THROUGH BOILER ON A DIGITAL COMPUTER
    KHORKOV, NS
    NOSKOV, AI
    ORSHANSKII, MB
    TYUPINA, TN
    THERMAL ENGINEERING, 1970, 17 (07) : 47 - +
  • [38] bbx75 Dynamic Model Identification of the Main Steam Temperature for Supercritical Once-through Boiler
    Lu, Hong-bo
    Zhang, Yu
    Wu, Chang-kai
    Sun, Wei-hua
    2012 INTERNATIONAL CONFERENCE ON FUTURE ELECTRICAL POWER AND ENERGY SYSTEM, PT B, 2012, 17 : 1704 - 1709
  • [39] Moving-boundary full scope simulation model of ultra-supercritical once-through boiler
    Xu, Ershu
    Yan, Qin
    Zhu, Huanlai
    Yang, Yongping
    INTERNATIONAL JOURNAL OF MODELLING IDENTIFICATION AND CONTROL, 2009, 7 (04) : 357 - 364
  • [40] Subspace Method based Dynamic Model Identification of the 600MW supercritical once-through boiler
    Wang Yinsong
    Kong Zihua
    Liu Hao
    SYSTEMS, ORGANIZATIONS AND MANAGEMENT: PROCEEDINGS OF THE 3RD WORKSHOP OF INTERNATIONAL SOCIETY IN SCIENTIFIC INVENTIONS, 2009, : 287 - 294