Start-Up and dynamic processes simulation of supercritical once-through boiler

被引:36
|
作者
Deng, Kangjie [1 ,2 ]
Yang, Chen [1 ,2 ]
Chen, Hao [1 ,2 ]
Zhou, Nana [1 ,2 ]
Huang, Shanglong [1 ,2 ]
机构
[1] Chongqing Univ, Minist Educ, Key Lab Lowgrade Energy Utilizat Technol & Syst, Chongqing 400030, Peoples R China
[2] Chongqing Univ, Coll Power Engn, 174 Shazhengjie, Chongqing 400030, Peoples R China
关键词
Supercritical; Boiler; Cold start-up; Dynamic; Fuel consumption; POWER-PLANT; COAL; VALIDATION; SYSTEM; MODEL;
D O I
10.1016/j.applthermaleng.2017.01.016
中图分类号
O414.1 [热力学];
学科分类号
摘要
The rapid expansion of the electricity demand causes the gap between the peak load and valley load increasing in China. Since the coal-fired supercritical power plant needs to be started up frequently, the operations of power plant become more flexible. During the start-up process, the operation parameters are off-designed, the multi-transient phenomenon is inevitable and the intensive emission always appears during varying working condition, it is difficult to ensure the operator of the real power plant to start up the boiler following the design curve. In this work, a new dynamic model for simulating start-up dynamic process of a 600 MW supercritical boiler is introduced in this paper. The six-equation solution of two-phase flow was applied to modeling the evaporator, and the process from ignition to the load at 30% Boiler Maximum Continuous Rating (BMCR) was simulated. The results demonstrate that the model is reasonable and dynamic behavior can be observed clearly. Also, these prove that the control strategy is advisable. Moreover, the fuel consumption of the start-up process can offer a reference to operator of the real power plant. The validated model is of high relevance for further optimizing the boiler start-up process. (C) 2017 Elsevier Ltd. All rights reserved.
引用
收藏
页码:937 / 946
页数:10
相关论文
共 50 条
  • [21] A dynamic hybrid model of supercritical once-through boiler-turbine unit including recirculation mode and once-through mode
    Xie, Yan
    Liu, Ji-zhen
    Zeng, De-liang
    Hu, Yong
    Li, Rui-lian
    Zhu, Yan-song
    [J]. ENERGY, 2024, 309
  • [22] An evaluation of designed Start-up System (SUS) for once-through steam generators
    Yu, Dali
    Peng, Minjun
    Xia, Genglei
    Mao, Wanchao
    Yang, Yang
    [J]. ANNALS OF NUCLEAR ENERGY, 2014, 66 : 146 - 151
  • [23] Mathematic model and simulation of steam generator in 900 MW supercritical once-through boiler
    Liu, Shu-Qing
    Yu, Sheng-Fang
    Zhou, Long
    [J]. Dongli Gongcheng/Power Engineering, 2005, 25 (03): : 335 - 338
  • [24] Mathematical Modeling And Dynamic Simulation of Intermediate Point Temperature for Ultra-supercritical Once-through Boiler I
    Chen, Shihe
    Li, Xin
    Wang, Zhenyu
    Fang, Yanjun
    [J]. 6TH INTERNATIONAL CONFERENCE ON SOFT COMPUTING AND INTELLIGENT SYSTEMS, AND THE 13TH INTERNATIONAL SYMPOSIUM ON ADVANCED INTELLIGENT SYSTEMS, 2012, : 917 - 921
  • [25] INFLUENCE OF NONLINEARITY OF DYNAMIC PROPERTIES OF A ONCE-THROUGH BOILER ON TRANSIENT PROCESSES.
    Davidenko, K.Ya.
    [J]. Thermal Engineering (English translation of Teploenergetika), 1972, 19 (11): : 80 - 85
  • [26] Combustion adjustment of a 600 MW supercritical once-through boiler
    Yang, Zhen
    Zhuang, En-Ru
    Cao, Zi-Dong
    [J]. Dongli Gongcheng/Power Engineering, 2007, 27 (04): : 502 - 506
  • [27] NONLINEAR MATHEMATICAL-MODEL OF A SUPERCRITICAL ONCE-THROUGH BOILER
    RUSHCHIN.VM
    DAVIDENK.KY
    [J]. THERMAL ENGINEERING, 1972, 18 (07) : 110 - &
  • [28] START-UP AND DYNAMIC PROCESSES SIMULATION OF A DISTILLATION COLUMN
    SONG, HH
    YU, GC
    [J]. CHINESE JOURNAL OF CHEMICAL ENGINEERING, 1995, 3 (03) : 134 - 144
  • [29] START-UP AND DYNAMIC PROCESSES SIMULATION OF A DISTILLATION COLUMN
    宋海华
    余国琮
    [J]. Chinese Journal of Chemical Engineering, 1995, (03) : 13 - 23
  • [30] ONCE-THROUGH BOILER CONTROL
    KENNY, PL
    [J]. POWER ENGINEERING, 1968, 72 (01) : 36 - &