A dynamic hybrid model of supercritical once-through boiler-turbine unit including recirculation mode and once-through mode

被引:0
|
作者
Xie, Yan [1 ]
Liu, Ji-zhen [1 ]
Zeng, De-liang [1 ]
Hu, Yong [1 ]
Li, Rui-lian [1 ]
Zhu, Yan-song [1 ]
机构
[1] North China Elect Power Univ, State Key Lab Alternate Elect Power Syst Renewable, Beijing 102206, Peoples R China
关键词
Supercritical once-through boiler-turbine unit; Dynamic hybrid model; INFO; INFO-XGBoost; Recirculation mode; Once-through mode; POWER-PLANT; EVAPORATION SYSTEM; SIMULATION; STEAM;
D O I
10.1016/j.energy.2024.132941
中图分类号
O414.1 [热力学];
学科分类号
摘要
Supercritical once-through boiler-turbine units play a paramount role in maintaining grid stability owing to their exceptional efficiency and flexibility. Nevertheless, achieving precise modeling of this device under various operational conditions remains a significant challenge. This study conducts modeling and simulation of an actual supercritical once-through coal-fired power plant. The findings signify that the hybrid model proposed herein adeptly encompasses all operational modes of supercritical once-through units, including start-up recirculation mode and once-through mode. To bolster model precision, an optimization algorithm grounded on weighted mean of vectors (INFO) has been employed for parameter identification, while the INFO-XGBoost was utilized to fashion a machine learning model for static parameters. It has been validated that the developed model accurately captures the dynamic characteristics of the unit. Furthermore, the utilization of the INFO-XGboost to model static parameters has been proved to enable the errors in principal outputs of coordinated control system to be within 0.35 % of MAPE across the entire operational process, thus facilitating the design of more refined and intelligent control systems.
引用
收藏
页数:24
相关论文
共 50 条
  • [1] Analysis and Control of Once-through Boiler-Turbine Unit
    Huang Weijian
    Wu Yuzhong
    Kan Weimin
    Zhang Xi
    [J]. ENERGY AND POWER TECHNOLOGY, PTS 1 AND 2, 2013, 805-806 : 678 - 681
  • [2] A dynamic nonlinear model for a once-through boiler-turbine unit in low load
    Niu, Yuguang
    Du, Ming
    Ge, Weichun
    Luo, Huanhuan
    Zhou, Guiping
    [J]. APPLIED THERMAL ENGINEERING, 2019, 161
  • [3] A dynamic model for supercritical once-through circulating fluidized bed boiler-turbine units
    Zhang, Hongfu
    Gao, Mingming
    Fan, Haohao
    Zhang, Kaiping
    Zhang, Jiahui
    [J]. ENERGY, 2022, 241
  • [4] A dynamic mathematical model of an ultra-supercritical coal fired once-through boiler-turbine unit
    Fan, He
    Zhang, Yu-fei
    Su, Zhi-gang
    Wang, Ben
    [J]. APPLIED ENERGY, 2017, 189 : 654 - 666
  • [5] A dynamic model used for controller design of a coal fired once-through boiler-turbine unit
    Liu, Ji-Zhen
    Yan, Shu
    Zeng, De-Liang
    Hu, Yong
    Lv, You
    [J]. ENERGY, 2015, 93 : 2069 - 2078
  • [6] Disturbance Rejection Model Predictive Control of Ultra-Supercritical Once-Through Boiler-Turbine Unit
    Zhang, Fan
    Xue, Yali
    Li, Donghai
    Shen, Jiong
    [J]. 2018 37TH CHINESE CONTROL CONFERENCE (CCC), 2018, : 3582 - 3587
  • [7] A dynamic mathematical model used for controller design of a supercritical once-through boiler-turbine unit in all load conditions
    Xie, Yan
    Liu, Ji-zhen
    Zeng, De-liang
    Hu, Yong
    Zhu, Yan-song
    Li, Rui-lian
    [J]. APPLIED THERMAL ENGINEERING, 2024, 248
  • [8] A Dynamic Nonlinear Model of Once-Through Boiler-Turbine Units with Superheated Steam Temperature
    Fan, He
    Su, Zhi-gang
    Wang, Pei-hong
    Lee, Kwang Y.
    [J]. 2020 IEEE POWER & ENERGY SOCIETY GENERAL MEETING (PESGM), 2020,
  • [9] A dynamic mathematical model for once-through boiler-turbine units with superheated steam temperature
    Fan, He
    Su, Zhi-gang
    Wang, Pei-hong
    Lee, Kwang Y.
    [J]. APPLIED THERMAL ENGINEERING, 2020, 170
  • [10] SIMULATION OF A SUPERCRITICAL ONCE-THROUGH BOILER
    SUZUKI, Y
    PAK, PS
    UCHIDA, Y
    [J]. SIMULATION, 1979, 33 (06) : 181 - 193