Supercritical OTB (once-through boiler) units with high steam temperature and pressure have been widely used in modern power plants due to their high cycle efficiency and less emissions. To ensure the effective operation of such power generation systems, it is necessary to build a model for the design of the overall control system. There are already detailed models of once-through boilers; however, their complexity prevents them from being applied in the controller design. This study describes a lumped parameter dynamic model that has a relatively low complexity while faithfully capturing the essential overall plant dynamics. The model structure was derived by fundamental physical laws utilizing reasonable simplifications and data analysis to avoid the phase transition position problem. Parameter identification for the model structure was completed using operational data from a 1000 MW ultra-supercritical OTB. The model was determined to be reasonable by comparison tests between computed data and measured data for both steady and dynamic states. The simplified model is verified to have appropriate fidelity in control system design to achieve effective and economic operation of the unit. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:2069 / 2078
页数:10
相关论文
共 50 条
  • [1] A dynamic mathematical model of an ultra-supercritical coal fired once-through boiler-turbine unit
    Fan, He
    Zhang, Yu-fei
    Su, Zhi-gang
    Wang, Ben
    [J]. APPLIED ENERGY, 2017, 189 : 654 - 666
  • [2] A dynamic mathematical model used for controller design of a supercritical once-through boiler-turbine unit in all load conditions
    Xie, Yan
    Liu, Ji-zhen
    Zeng, De-liang
    Hu, Yong
    Zhu, Yan-song
    Li, Rui-lian
    [J]. APPLIED THERMAL ENGINEERING, 2024, 248
  • [3] A dynamic nonlinear model for a once-through boiler-turbine unit in low load
    Niu, Yuguang
    Du, Ming
    Ge, Weichun
    Luo, Huanhuan
    Zhou, Guiping
    [J]. APPLIED THERMAL ENGINEERING, 2019, 161
  • [4] Affine nonlinear control for an ultra-supercritical coal fired once-through boiler-turbine unit
    Zhou, Hong
    Chen, Cheng
    Lai, Jingang
    Lu, Xiaoqing
    Deng, Qijun
    Gao, Xingran
    Lei, Zhongcheng
    [J]. ENERGY, 2018, 153 : 638 - 649
  • [5] Analysis and Control of Once-through Boiler-Turbine Unit
    Huang Weijian
    Wu Yuzhong
    Kan Weimin
    Zhang Xi
    [J]. ENERGY AND POWER TECHNOLOGY, PTS 1 AND 2, 2013, 805-806 : 678 - 681
  • [6] A dynamic hybrid model of supercritical once-through boiler-turbine unit including recirculation mode and once-through mode
    Xie, Yan
    Liu, Ji-zhen
    Zeng, De-liang
    Hu, Yong
    Li, Rui-lian
    Zhu, Yan-song
    [J]. ENERGY, 2024, 309
  • [7] A dynamic model used for controller design for fast cut back of coal-fired boiler-turbine plant
    Wang, Di
    Zhou, Yunlong
    Li, Xiaoli
    [J]. ENERGY, 2018, 144 : 526 - 534
  • [8] A Dynamic Nonlinear Model of Once-Through Boiler-Turbine Units with Superheated Steam Temperature
    Fan, He
    Su, Zhi-gang
    Wang, Pei-hong
    Lee, Kwang Y.
    [J]. 2020 IEEE POWER & ENERGY SOCIETY GENERAL MEETING (PESGM), 2020,
  • [9] A dynamic model for supercritical once-through circulating fluidized bed boiler-turbine units
    Zhang, Hongfu
    Gao, Mingming
    Fan, Haohao
    Zhang, Kaiping
    Zhang, Jiahui
    [J]. ENERGY, 2022, 241
  • [10] A dynamic mathematical model for once-through boiler-turbine units with superheated steam temperature
    Fan, He
    Su, Zhi-gang
    Wang, Pei-hong
    Lee, Kwang Y.
    [J]. APPLIED THERMAL ENGINEERING, 2020, 170