Subspace Method based Dynamic Model Identification of the 600MW supercritical once-through boiler

被引:0
|
作者
Wang Yinsong [1 ]
Kong Zihua [1 ]
Liu Hao [1 ]
机构
[1] N China Elect Power Univ, Baoding 071003, Peoples R China
关键词
Subspace identification method; Close-loop identification; Principle component analysis; Thermal control system; Supercritical once-through boiler;
D O I
暂无
中图分类号
C93 [管理学]; O22 [运筹学];
学科分类号
070105 ; 12 ; 1201 ; 1202 ; 120202 ;
摘要
As a kind of identification algorithm, the subspace identification method has attracted more and more researchers' attention, which has the advantages of fast computing, without parameterizing, and so on. This paper analyzes a kind of subspace identification algorithm based on principle component analysis,and uses it to identify the dynamic model of the 600MW supercritical once-through boiler. For the No. 1 supercritical once-through boiler of a power plant, we choose the main input and output data as the identification data. The identification results show the once-through boiler dynamic response are accordant with the practical process, the method is feasible and the model is useful in the thermal control system.
引用
收藏
页码:287 / 294
页数:8
相关论文
共 50 条
  • [1] Sensitivity analysis of 600MW supercritical pressure once-through boiler
    Huang, JT
    Chen, TK
    [J]. MULTIPHASE FLOW AND HEAT TRANSFER, 1999, : 403 - 409
  • [2] Analysis on High Rates of Scaling and Salt Accumulation of 600MW Supercritical Once-through Boiler
    Zhang, Xiao Ni
    Li, Xian Min
    Li, Chang Ming
    [J]. PROGRESS IN STRUCTURE, PTS 1-4, 2012, 166-169 : 620 - +
  • [3] EXPERIMENTAL DYNAMIC CHARACTERISTICS OF A SUPERCRITICAL ONCE-THROUGH BOILER
    SULLER, PL
    ROMANOV, AF
    [J]. THERMAL ENGINEERING, 1973, 19 (05) : 79 - 86
  • [4] SIMULATION OF A SUPERCRITICAL ONCE-THROUGH BOILER
    SUZUKI, Y
    PAK, PS
    UCHIDA, Y
    [J]. SIMULATION, 1979, 33 (06) : 181 - 193
  • [5] SIMULATION OF SUPERCRITICAL ONCE-THROUGH BOILER
    SUZUKI, Y
    PAK, PS
    UCHIDA, Y
    [J]. ELECTRICAL ENGINEERING IN JAPAN, 1978, 98 (03) : 120 - 127
  • [6] bbx75 Dynamic Model Identification of the Main Steam Temperature for Supercritical Once-through Boiler
    Lu, Hong-bo
    Zhang, Yu
    Wu, Chang-kai
    Sun, Wei-hua
    [J]. 2012 INTERNATIONAL CONFERENCE ON FUTURE ELECTRICAL POWER AND ENERGY SYSTEM, PT B, 2012, 17 : 1704 - 1709
  • [7] A dynamic hybrid model of supercritical once-through boiler-turbine unit including recirculation mode and once-through mode
    Xie, Yan
    Liu, Ji-zhen
    Zeng, De-liang
    Hu, Yong
    Li, Rui-lian
    Zhu, Yan-song
    [J]. ENERGY, 2024, 309
  • [8] NONLINEAR MATHEMATICAL-MODEL OF A SUPERCRITICAL ONCE-THROUGH BOILER
    RUSHCHIN.VM
    DAVIDENK.KY
    [J]. THERMAL ENGINEERING, 1972, 18 (07) : 110 - &
  • [9] A Numerical Model Prediction for Boiling Multi Channel Flow Rate Distribution andApplication in 600MW Supercritical Variable-Pressure Once-Through Boiler with Vertical Tube Coils
    Chen Tingkuan(National Lab. on Multiphase Flow
    [J]. Journal of Thermal Science, 1996, (02) : 75 - 81
  • [10] A dynamic model for supercritical once-through circulating fluidized bed boiler-turbine units
    Zhang, Hongfu
    Gao, Mingming
    Fan, Haohao
    Zhang, Kaiping
    Zhang, Jiahui
    [J]. ENERGY, 2022, 241