Sensitivity analysis of 600MW supercritical pressure once-through boiler

被引:0
|
作者
Huang, JT [1 ]
Chen, TK [1 ]
机构
[1] Xian Jiao Tong Univ, State Key Lab Multiphase Flow Power Engn, Xian 710049, Peoples R China
关键词
D O I
暂无
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Once-through boilers ate sensitive to disturbance due to their smaller water volume. Hydrodynamic instability may occur in heating tubes as heat load changes frequently. The water-wall tube may break due to overheat. This paper gives the formulas bf sensitivity coefficient of flow, pressure loss and output enthalpy. On the basis of these formulas, the effect of several kinds of factors oil sensitivity of 600MW supercritical once-through boiler is studied. The formulas can be used for sensitivity analysis of water-wall tube in once-through boiler.
引用
收藏
页码:403 / 409
页数:7