Micropolar pulsatile blood flow conveying nanoparticles in a stenotic tapered artery: NON-Newtonian pharmacodynamic simulation

被引:23
|
作者
Vasu, B. [1 ]
Dubey, Ankita [1 ]
Beg, O. Anwar [2 ]
Gorla, Rama Subba Reddy [3 ]
机构
[1] Motilal Nehru Natl Inst Technol Allahabad, Dept Math, Prayagraj 211004, Uttar Pradesh, India
[2] Salford Univ, Sch Sci Engn & Environm SEE, Dept Mech & Aeronaut Engn, Newton Bldg, Manchester M5 4WT, Lancs, England
[3] Air Force Inst Technol, Dept Aeronaut & Astronaut, Dayton, OH 45433 USA
关键词
Nano-pharmacodynamics; Tapered artery; Hemo-rheology; Micropolar fluid model; Nano-drugs; Pressure gradient; Wall shear stress; Hemodynamic impedance; Finite Element Method; FreeFEM plus; NUMERICAL-SIMULATION; STENOSED ARTERY; HEAT-TRANSFER; FLUID MODEL; HEMODYNAMICS; SUSPENSION; RHEOLOGY; DELIVERY; VESSEL; BODY;
D O I
10.1016/j.compbiomed.2020.104025
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
Two-dimensional rheological laminar hemodynamics through a diseased tapered artery with a mild stenosis present is simulated theoretically and computationally. The effect of different metallic nanoparticles homogeneously suspended in the blood is considered, motivated by drug delivery (pharmacology) applications. The Eringen micropolar model has been discussed for hemorheological characteristics in the whole arterial region. The conservation equations for mass, linear momentum, angular momentum (micro-rotation), and energy and nanoparticle species are normalized by employing suitable non-dimensional variables. The transformed equations are solved numerically subject to physically appropriate boundary conditions using the finite element method with the variational formulation scheme available in the FreeFEM++ code. A good correlation is achieved between the FreeFEM++ computations and existing results. The effect of selected parameters (taper angle, Prandtl number, Womersley parameter, pulsatile constants, and volumetric concentration) on velocity, temperature, and micro-rotational (Eringen angular) velocity has been calculated for a stenosed arterial segment. Wall shear stress, volumetric flow rate, and hemodynamic impedance of blood flow are also computed. Colour contours and graphs are employed to visualize the simulated blood flow characteristics. It is observed that by increasing Prandtl number (Pr), the micro-rotational velocity decreases i.e., microelement (blood cell) spin is suppressed. Wall shear stress decreases with the increment in pulsatile parameters (B and e), whereas linear velocity increases with a decrement in these parameters. Furthermore, the velocity decreases in the tapered region with elevation in the Womersley parameter (alpha). The simulations are relevant to transport phenomena in pharmacology and nano-drug targeted delivery in hematology.
引用
收藏
页数:26
相关论文
共 50 条
  • [1] Magnetic Effects on Unsteady Non-Newtonian Blood Flow through a Tapered and Overlapping Stenotic Artery
    Babatunde, Abiodun J.
    Dada, Moses S.
    [J]. APPLICATIONS AND APPLIED MATHEMATICS-AN INTERNATIONAL JOURNAL, 2024, 19 (01):
  • [2] Three dimensional pulsatile non-Newtonian flow in a stenotic vessel
    Husain, I.
    Langdon, C.
    Schwark, J.
    [J]. Lecture Notes in Electrical Engineering, 2014, 307 : 55 - 64
  • [3] Pulsatile pressure-driven non-Newtonian blood flow through a porous stenotic artery: A computational analysis
    Fahim, Muhammad
    Sajid, Muhammad
    Ali, Nasir
    [J]. NUMERICAL HEAT TRANSFER PART A-APPLICATIONS, 2024,
  • [4] Effects of unsteadiness and non-Newtonian rheology on blood flow through a tapered time-variant stenotic artery
    Zaman, A.
    Ali, N.
    Sajid, M.
    Hayat, T.
    [J]. AIP ADVANCES, 2015, 5 (03):
  • [5] Numerical simulation of pulsatile non-Newtonian flow in the carotid artery bifurcation
    Yubo Fan
    Wentao Jiang
    Yuanwen Zou
    Jinchuan Li
    Junkai Chen
    Xiaoyan Deng
    [J]. Acta Mechanica Sinica, 2009, 25 : 249 - 255
  • [6] Numerical simulation of pulsatile non-Newtonian flow in the carotid artery bifurcation
    Y. Fan X. Deng School of Biological Science and Medical Engineering
    [J]. Acta Mechanica Sinica, 2009, (02) : 249 - 255
  • [7] Numerical simulation of pulsatile non-Newtonian flow in the carotid artery bifurcation
    Fan, Yubo
    Jiang, Wentao
    Zou, Yuanwen
    Li, Jinchuan
    Chen, Junkai
    Deng, Xiaoyan
    [J]. ACTA MECHANICA SINICA, 2009, 25 (02) : 249 - 255
  • [8] Non-Newtonian model study for blood flow through a tapered artery with a stenosis
    Akbar, Noreen Sher
    [J]. ALEXANDRIA ENGINEERING JOURNAL, 2016, 55 (01) : 321 - 329
  • [9] PULSATILE NON-NEWTONIAN BLOOD-FLOW SIMULATION THROUGH A BIFURCATION WITH AN ANEURYSM
    PERKTOLD, K
    PETER, R
    RESCH, M
    [J]. BIORHEOLOGY, 1989, 26 (06) : 1011 - 1030
  • [10] Newtonian and Non-Newtonian Pulsatile Blood Flow in Arteries with Model Aneurysms
    Tabakova, S.
    Raynov, P.
    Nikolov, N.
    Radev, St.
    [J]. ADVANCED COMPUTING IN INDUSTRIAL MATHEMATICS, 2017, 681 : 187 - 197