Micropolar pulsatile blood flow conveying nanoparticles in a stenotic tapered artery: NON-Newtonian pharmacodynamic simulation

被引:23
|
作者
Vasu, B. [1 ]
Dubey, Ankita [1 ]
Beg, O. Anwar [2 ]
Gorla, Rama Subba Reddy [3 ]
机构
[1] Motilal Nehru Natl Inst Technol Allahabad, Dept Math, Prayagraj 211004, Uttar Pradesh, India
[2] Salford Univ, Sch Sci Engn & Environm SEE, Dept Mech & Aeronaut Engn, Newton Bldg, Manchester M5 4WT, Lancs, England
[3] Air Force Inst Technol, Dept Aeronaut & Astronaut, Dayton, OH 45433 USA
关键词
Nano-pharmacodynamics; Tapered artery; Hemo-rheology; Micropolar fluid model; Nano-drugs; Pressure gradient; Wall shear stress; Hemodynamic impedance; Finite Element Method; FreeFEM plus; NUMERICAL-SIMULATION; STENOSED ARTERY; HEAT-TRANSFER; FLUID MODEL; HEMODYNAMICS; SUSPENSION; RHEOLOGY; DELIVERY; VESSEL; BODY;
D O I
10.1016/j.compbiomed.2020.104025
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
Two-dimensional rheological laminar hemodynamics through a diseased tapered artery with a mild stenosis present is simulated theoretically and computationally. The effect of different metallic nanoparticles homogeneously suspended in the blood is considered, motivated by drug delivery (pharmacology) applications. The Eringen micropolar model has been discussed for hemorheological characteristics in the whole arterial region. The conservation equations for mass, linear momentum, angular momentum (micro-rotation), and energy and nanoparticle species are normalized by employing suitable non-dimensional variables. The transformed equations are solved numerically subject to physically appropriate boundary conditions using the finite element method with the variational formulation scheme available in the FreeFEM++ code. A good correlation is achieved between the FreeFEM++ computations and existing results. The effect of selected parameters (taper angle, Prandtl number, Womersley parameter, pulsatile constants, and volumetric concentration) on velocity, temperature, and micro-rotational (Eringen angular) velocity has been calculated for a stenosed arterial segment. Wall shear stress, volumetric flow rate, and hemodynamic impedance of blood flow are also computed. Colour contours and graphs are employed to visualize the simulated blood flow characteristics. It is observed that by increasing Prandtl number (Pr), the micro-rotational velocity decreases i.e., microelement (blood cell) spin is suppressed. Wall shear stress decreases with the increment in pulsatile parameters (B and e), whereas linear velocity increases with a decrement in these parameters. Furthermore, the velocity decreases in the tapered region with elevation in the Womersley parameter (alpha). The simulations are relevant to transport phenomena in pharmacology and nano-drug targeted delivery in hematology.
引用
收藏
页数:26
相关论文
共 50 条
  • [31] Non-Newtonian blood flow simulation in cerebral aneurysms
    Bernsdorf, J.
    Wang, D.
    [J]. COMPUTERS & MATHEMATICS WITH APPLICATIONS, 2009, 58 (05) : 1024 - 1029
  • [32] Numerical Study of Pulsatile Blood Flow in Stenotic Artery
    Seo, Taewon
    Buriev, Bahtiyor
    [J]. TRANSACTIONS OF THE KOREAN SOCIETY OF MECHANICAL ENGINEERS B, 2008, 32 (11) : 891 - 896
  • [33] PULSATILE BLOOD-FLOW IN A POROUS STENOTIC ARTERY
    CHAKRAVARTY, S
    DATTA, A
    [J]. MATHEMATICAL AND COMPUTER MODELLING, 1992, 16 (02) : 35 - 54
  • [34] Large-eddy simulation of pulsatile non-Newtonian flow in a constricted channel
    Molla, Md Mamun
    Hossain, Afzal
    Wang, Bing-Chen
    Kuhn, David C. S.
    [J]. PROGRESS IN COMPUTATIONAL FLUID DYNAMICS, 2012, 12 (04): : 231 - 242
  • [35] Mathematical modelling of time dependent flow of non-Newtonian fluid through unsymmetric stenotic tapered artery: Effects of catheter and slip velocity
    Reddy, J. V. Ramana
    Srikanth, D.
    Murthy, S. V. S. S. N. V. G. Krishna
    [J]. MECCANICA, 2016, 51 (01) : 55 - 69
  • [36] Non-Newtonian Pulsatile Blood Flow Dynamics around a Y- Junction
    Bhowmick, Dhiman
    Hasan, Md. Toukir
    Hasan, A. B. M. Toufique
    [J]. 8TH BSME INTERNATIONAL CONFERENCE ON THERMAL ENGINEERING, 2019, 2121
  • [37] Mathematical modelling of time dependent flow of non-Newtonian fluid through unsymmetric stenotic tapered artery: Effects of catheter and slip velocity
    J. V. Ramana Reddy
    D. Srikanth
    S. V. S. S. N. V. G. Krishna Murthy
    [J]. Meccanica, 2016, 51 : 55 - 69
  • [38] Modeling pulsatile flow in aortic aneurysms: Effect of non-Newtonian properties of blood
    Khanafer, Khalil M.
    Gadhoke, Prateek
    Berguer, Ramon
    Bull, Joseph L.
    [J]. BIORHEOLOGY, 2006, 43 (05) : 661 - 679
  • [39] Effect of non-Newtonian and pulsatile blood flow on mass transport in the human aorta
    Liu, Xiao
    Fan, Yubo
    Deng, Xiaoyan
    Zhan, Fan
    [J]. JOURNAL OF BIOMECHANICS, 2011, 44 (06) : 1123 - 1131
  • [40] Non-Newtonian Flow of Blood in a Catheterized Bifurcated Stenosed Artery
    Misra, Jagadis Chandra
    Shit, Gopal Chandra
    Pramanik, Ranjan
    [J]. JOURNAL OF BIONIC ENGINEERING, 2018, 15 (01) : 173 - 184