Micropolar pulsatile blood flow conveying nanoparticles in a stenotic tapered artery: NON-Newtonian pharmacodynamic simulation

被引:23
|
作者
Vasu, B. [1 ]
Dubey, Ankita [1 ]
Beg, O. Anwar [2 ]
Gorla, Rama Subba Reddy [3 ]
机构
[1] Motilal Nehru Natl Inst Technol Allahabad, Dept Math, Prayagraj 211004, Uttar Pradesh, India
[2] Salford Univ, Sch Sci Engn & Environm SEE, Dept Mech & Aeronaut Engn, Newton Bldg, Manchester M5 4WT, Lancs, England
[3] Air Force Inst Technol, Dept Aeronaut & Astronaut, Dayton, OH 45433 USA
关键词
Nano-pharmacodynamics; Tapered artery; Hemo-rheology; Micropolar fluid model; Nano-drugs; Pressure gradient; Wall shear stress; Hemodynamic impedance; Finite Element Method; FreeFEM plus; NUMERICAL-SIMULATION; STENOSED ARTERY; HEAT-TRANSFER; FLUID MODEL; HEMODYNAMICS; SUSPENSION; RHEOLOGY; DELIVERY; VESSEL; BODY;
D O I
10.1016/j.compbiomed.2020.104025
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
Two-dimensional rheological laminar hemodynamics through a diseased tapered artery with a mild stenosis present is simulated theoretically and computationally. The effect of different metallic nanoparticles homogeneously suspended in the blood is considered, motivated by drug delivery (pharmacology) applications. The Eringen micropolar model has been discussed for hemorheological characteristics in the whole arterial region. The conservation equations for mass, linear momentum, angular momentum (micro-rotation), and energy and nanoparticle species are normalized by employing suitable non-dimensional variables. The transformed equations are solved numerically subject to physically appropriate boundary conditions using the finite element method with the variational formulation scheme available in the FreeFEM++ code. A good correlation is achieved between the FreeFEM++ computations and existing results. The effect of selected parameters (taper angle, Prandtl number, Womersley parameter, pulsatile constants, and volumetric concentration) on velocity, temperature, and micro-rotational (Eringen angular) velocity has been calculated for a stenosed arterial segment. Wall shear stress, volumetric flow rate, and hemodynamic impedance of blood flow are also computed. Colour contours and graphs are employed to visualize the simulated blood flow characteristics. It is observed that by increasing Prandtl number (Pr), the micro-rotational velocity decreases i.e., microelement (blood cell) spin is suppressed. Wall shear stress decreases with the increment in pulsatile parameters (B and e), whereas linear velocity increases with a decrement in these parameters. Furthermore, the velocity decreases in the tapered region with elevation in the Womersley parameter (alpha). The simulations are relevant to transport phenomena in pharmacology and nano-drug targeted delivery in hematology.
引用
收藏
页数:26
相关论文
共 50 条
  • [41] Non-Newtonian flow of blood in a catheterized bifurcated stenosed artery
    Jagadis Chandra Misra
    Gopal Chandra Shit
    Ranjan Pramanik
    [J]. Journal of Bionic Engineering, 2018, 15 : 173 - 184
  • [42] Simulation of Non-Newtonian Blood Flow in Diverging Bifurcated Vessels
    Chu, J.
    Xiao, L. L.
    Lin, C. S.
    Liu, S.
    Zhang, K. X.
    Wei, P.
    [J]. JOURNAL OF APPLIED FLUID MECHANICS, 2024, 17 (06) : 1204 - 1216
  • [43] Simulation of Non-Newtonian Blood Flow by Lattice Boltzman Method
    Ji Yu-Pin
    Kang Xiu-Ying
    Liu Da-He
    [J]. CHINESE PHYSICS LETTERS, 2010, 27 (09)
  • [44] Computer simulation of MHD blood conveying gold nanoparticles as a third grade non-Newtonian nanofluid in a hollow porous vessel
    Hatami, M.
    Hatami, J.
    Ganji, D. D.
    [J]. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2014, 113 (02) : 632 - 641
  • [45] Numerical investigation of unsteady pulsatile Newtonian/non-Newtonian blood flow through curved stenosed arteries
    Lakzian, E.
    Akbarzadeh, P.
    [J]. BIO-MEDICAL MATERIALS AND ENGINEERING, 2020, 30 (5-6) : 525 - 540
  • [46] EFFECT OF NON-NEWTONIAN BEHAVIOR ON VOLUMETRIC FLOW RATE FOR PULSATILE FLOW OF BLOOD IN A RIGID TUBE
    BERGMAN, LE
    DEWITT, KJ
    FERNANDEZ, RC
    BOTWIN, MR
    [J]. JOURNAL OF BIOMECHANICS, 1971, 4 (03) : 229 - +
  • [47] Multiphase non-Newtonian effects on pulsatile hemodynamics in a coronary artery
    Kim, Yong Hyun
    VandeVord, Pamela J.
    Lee, Joon Sang
    [J]. INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN FLUIDS, 2008, 58 (07) : 803 - 825
  • [48] Comparative Study of Newtonian and Non-Newtonian Blood Flow through a Stenosed Carotid Artery
    Rahman, Mohammad Matiur
    Hossain, Md. Anwar
    Mamun, Khairuzzaman
    Akhter, Most. Nasrin
    [J]. PROCEEDINGS OF THE 12TH INTERNATIONAL CONFERENCE ON MECHANICAL ENGINEERING (ICME 2017), 2018, 1980
  • [49] SIMULATION OF NON-NEWTONIAN FLOW IN A HYDROCYCLONE
    DYAKOWSKI, T
    HORNUNG, G
    WILLIAMS, RA
    [J]. CHEMICAL ENGINEERING RESEARCH & DESIGN, 1994, 72 (A4): : 513 - 520
  • [50] Numerical computation of pulsatile hemodynamics and diagnostic concern of coronary bifurcated artery flow for Newtonian and non-Newtonian fluid
    Uddin, Md. Jashim
    Bangalee, M. Z. I.
    Ferdows, M.
    [J]. HELIYON, 2023, 9 (07)