Effects of unsteadiness and non-Newtonian rheology on blood flow through a tapered time-variant stenotic artery

被引:29
|
作者
Zaman, A. [1 ]
Ali, N. [1 ]
Sajid, M. [2 ]
Hayat, T. [3 ,4 ]
机构
[1] Int Islamic Univ, Dept Math & Stat, Islamabad 44000, Pakistan
[2] PINSTECH, Theoret Phys Div, Islamabad 44000, Pakistan
[3] Quaid I Azam Univ, Dept Math, Islamabad 44000, Pakistan
[4] King Abdulaziz Univ, Fac Sci, Dept Math, Nonlinear Anal & Appl Math NAAM Res Grp, Jeddah 21589, Saudi Arabia
来源
AIP ADVANCES | 2015年 / 5卷 / 03期
关键词
PULSATILE FLOW; BODY ACCELERATION; STEADY FLOW; HEMODYNAMICS; MODEL; FLUID;
D O I
10.1063/1.4916043
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
A two-dimensional model is used to analyze the unsteady pulsatile flow of blood through a tapered artery with stenosis. The rheology of the flowing blood is captured by the constitutive equation of Carreau model. The geometry of the time-variant stenosis has been used to carry out the present analysis. The flow equations are set up under the assumption that the lumen radius is sufficiently smaller than the wavelength of the pulsatile pressure wave. Aradial coordinate transformation is employed to immobilize the effect of the vessel wall. The resulting partial differential equations along with the boundary and initial conditions are solved using finite difference method. The dimensionless radial and axial velocity, volumetric flow rate, resistance impedance and wall shear stress are analyzed for normal and diseased artery with particular focus on variation of these quantities with non-Newtonian parameters. (C) 2015 Author(s).
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Magnetic Effects on Unsteady Non-Newtonian Blood Flow through a Tapered and Overlapping Stenotic Artery
    Babatunde, Abiodun J.
    Dada, Moses S.
    [J]. APPLICATIONS AND APPLIED MATHEMATICS-AN INTERNATIONAL JOURNAL, 2024, 19 (01):
  • [2] A FRACTIONAL MODEL FOR TIME-VARIANT NON-NEWTONIAN FLOW
    Yang, Xu
    Chen, Wen
    Xiao, Rui
    Ling, Leevan
    [J]. THERMAL SCIENCE, 2017, 21 (01): : 61 - 68
  • [3] Mathematical modelling of time dependent flow of non-Newtonian fluid through unsymmetric stenotic tapered artery: Effects of catheter and slip velocity
    Reddy, J. V. Ramana
    Srikanth, D.
    Murthy, S. V. S. S. N. V. G. Krishna
    [J]. MECCANICA, 2016, 51 (01) : 55 - 69
  • [4] Mathematical modelling of time dependent flow of non-Newtonian fluid through unsymmetric stenotic tapered artery: Effects of catheter and slip velocity
    J. V. Ramana Reddy
    D. Srikanth
    S. V. S. S. N. V. G. Krishna Murthy
    [J]. Meccanica, 2016, 51 : 55 - 69
  • [5] Non-Newtonian model study for blood flow through a tapered artery with a stenosis
    Akbar, Noreen Sher
    [J]. ALEXANDRIA ENGINEERING JOURNAL, 2016, 55 (01) : 321 - 329
  • [6] Slip effects on unsteady non-Newtonian blood flow through an inclined catheterized overlapping stenotic artery
    Zaman, Akbar
    Ali, Nasir
    Sajid, M.
    [J]. AIP ADVANCES, 2016, 6 (01):
  • [7] Micropolar pulsatile blood flow conveying nanoparticles in a stenotic tapered artery: NON-Newtonian pharmacodynamic simulation
    Vasu, B.
    Dubey, Ankita
    Beg, O. Anwar
    Gorla, Rama Subba Reddy
    [J]. COMPUTERS IN BIOLOGY AND MEDICINE, 2020, 126
  • [8] FORCED CONVECTION IN A LID-DRIVEN NON-NEWTONIAN BLOOD FLOW THROUGH A STENOTIC ARTERY
    Fernandes, Ignatius
    Bodke, Nitin
    [J]. JOURNAL OF THE SERBIAN SOCIETY FOR COMPUTATIONAL MECHANICS, 2021, 15 (01) : 65 - 80
  • [9] EFFECTS OF STENOSIS ON NON-NEWTONIAN FLOW OF THE BLOOD IN AN ARTERY
    SHUKLA, JB
    PARIHAR, RS
    RAO, BRP
    [J]. BULLETIN OF MATHEMATICAL BIOLOGY, 1980, 42 (03) : 283 - 294
  • [10] Pulsatile pressure-driven non-Newtonian blood flow through a porous stenotic artery: A computational analysis
    Fahim, Muhammad
    Sajid, Muhammad
    Ali, Nasir
    [J]. NUMERICAL HEAT TRANSFER PART A-APPLICATIONS, 2024,