Pulsatile pressure-driven non-Newtonian blood flow through a porous stenotic artery: A computational analysis

被引:3
|
作者
Fahim, Muhammad [1 ]
Sajid, Muhammad [1 ]
Ali, Nasir [1 ]
机构
[1] Int Islamic Univ, Dept Math & Stat, Islamabad, Pakistan
关键词
Carreau fluid; finite difference technique; nonisothermal flow; porous medium; stenosed channel; STENOSED ARTERIES; FLUID; MODEL; TRANSPORT; ACCUMULATION; GRADIENT; VELOCITY; WALL;
D O I
10.1080/10407782.2024.2326961
中图分类号
O414.1 [热力学];
学科分类号
摘要
Blood flow through a narrowed artery, such as those caused by plaque buildup, can lead to various cardiovascular diseases. Therefore, studying this phenomenon is essential for developing better treatments and understanding the underlying mechanisms. In this study, a mathematical model is developed to simulate blood flow through stenotic arteries with porous walls. The familiar Navier-Stokes equations are executed to simulate flow, whereas the Carreau fluid model is employed to quantify blood rheology. This model illustrates both Newtonian and non-Newtonian characteristics depending on the shear rate. Other than that, the blood vessel is assumed to have a moderate level of stenosis with porous saturated walls. The solution of the governed partial differential equations is carried out using a finite difference scheme. Our research addresses the impacts of permeability and rheological parameters, stenosis size, Brinkman number, and Prandtl number on blood velocity, flow rate, resistance to flow, wall shear stress, and temperature distribution. The findings demonstrate that while flow resistance reduces, the velocity, shear stress, and flow rate increase with high permeability values. Conversely, as the stenosis amplitude increases, the magnitude of wall shear stresses, velocity, and flow rates decrease. In addition, blood rheology also has the potential to transfigure the aforementioned factors. We also found that the temperature distribution increases with the Brinkman number, stenosis size, permeability, and power law exponent. It drives down, however, by raising the values of Weissenberg number and Prandtl number. Collectively, our findings contribute to a better understanding of the complicated phenomena of blood flow in stenotic vessels with porous saturated walls. The findings of this study may be valuable in establishing improved therapies for cardiovascular disorders and formulating more precise mathematical models to forecast blood flow in vivo.
引用
收藏
页数:21
相关论文
共 50 条
  • [1] FORCED CONVECTION IN A LID-DRIVEN NON-NEWTONIAN BLOOD FLOW THROUGH A STENOTIC ARTERY
    Fernandes, Ignatius
    Bodke, Nitin
    [J]. JOURNAL OF THE SERBIAN SOCIETY FOR COMPUTATIONAL MECHANICS, 2021, 15 (01) : 65 - 80
  • [2] Micropolar pulsatile blood flow conveying nanoparticles in a stenotic tapered artery: NON-Newtonian pharmacodynamic simulation
    Vasu, B.
    Dubey, Ankita
    Beg, O. Anwar
    Gorla, Rama Subba Reddy
    [J]. COMPUTERS IN BIOLOGY AND MEDICINE, 2020, 126
  • [3] MHD instability of pressure-driven flow of a non-Newtonian fluid
    B. M. Shankar
    Jai Kumar
    I. S. Shivakumara
    S. B. Naveen Kumar
    [J]. SN Applied Sciences, 2019, 1
  • [4] MHD instability of pressure-driven flow of a non-Newtonian fluid
    Shankar, B. M.
    Kumar, Jai
    Shivakumara, I. S.
    Kumar, S. B. Naveen
    [J]. SN APPLIED SCIENCES, 2019, 1 (12)
  • [5] Non-Newtonian pulsatile flow through an artery with two stenosis
    Kumar, Gaurav
    Kumar, Hitesh
    Mandia, Kabir
    Zunaid, M.
    Ansari, N. A.
    Husain, A.
    [J]. MATERIALS TODAY-PROCEEDINGS, 2021, 46 : 10793 - 10798
  • [6] Three dimensional pulsatile non-Newtonian flow in a stenotic vessel
    Husain, I.
    Langdon, C.
    Schwark, J.
    [J]. Lecture Notes in Electrical Engineering, 2014, 307 : 55 - 64
  • [7] Magnetic Effects on Unsteady Non-Newtonian Blood Flow through a Tapered and Overlapping Stenotic Artery
    Babatunde, Abiodun J.
    Dada, Moses S.
    [J]. APPLICATIONS AND APPLIED MATHEMATICS-AN INTERNATIONAL JOURNAL, 2024, 19 (01):
  • [8] STEADY PRESSURE-DRIVEN NON-NEWTONIAN FLOW IN A PARTIALLY FILLED PIPE
    DAVIS, AMJ
    MAI, TZ
    [J]. JOURNAL OF NON-NEWTONIAN FLUID MECHANICS, 1991, 41 (1-2) : 81 - 100
  • [9] PULSATILE BLOOD-FLOW IN A POROUS STENOTIC ARTERY
    CHAKRAVARTY, S
    DATTA, A
    [J]. MATHEMATICAL AND COMPUTER MODELLING, 1992, 16 (02) : 35 - 54
  • [10] Modeling analysis of pulsatile non-Newtonian blood flow in a renal bifurcated artery with stenosis
    Hamidah, Musammath Asma