Evaluation of a Pencil Beam Scanning Proton Dose Model for a Commercial Treatment Planning System

被引:0
|
作者
Patel, D. [1 ]
Poenisch, F. [1 ]
Sahoo, N. [1 ]
Zhu, X. [1 ]
Gillin, M. [1 ]
Janson, M. [2 ]
Mohan, R. [1 ]
Titt, U. [1 ]
机构
[1] Univ Texas MD Anderson Canc Ctr, Houston, TX 77030 USA
[2] RaySearch Labs, Stockholm, Sweden
关键词
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
SU-I-GPD-T
引用
收藏
页码:E261 / E261
页数:1
相关论文
共 50 条
  • [31] Determination of surface dose in pencil beam scanning proton therapy
    Kern, A.
    Baeumer, C.
    Kroeninger, K.
    Mertens, L.
    Timmermann, B.
    Walbersloh, J.
    Wulff, J.
    [J]. MEDICAL PHYSICS, 2020, 47 (05) : 2277 - 2288
  • [32] Influence of Proton Spot Properties On Patient Dose Reconstructions in Pencil Beam Scanning Treatment
    Yeom, Y.
    Kuzmin, G.
    Griffin, K.
    Mille, M.
    Polf, J.
    Langner, U.
    Jung, J.
    Lee, C.
    Shin, J.
    Ellis, D.
    Lee, C.
    [J]. MEDICAL PHYSICS, 2019, 46 (06) : E588 - E588
  • [33] PERFORMANCE EVALUATION OF THE CMS MODULEX TREATMENT PLANNING SYSTEM FOR PENCIL BEAM ELECTRON DOSE COMPUTATIONS
    KEYS, RA
    HARMS, WB
    WONG, JW
    PURDY, JA
    [J]. MEDICAL PHYSICS, 1985, 12 (04) : 533 - 533
  • [34] Development and Evaluation of a Pixel Detector System for Pencil Beam Scanning Proton Therapy
    Eichin, Michael
    Actis, O.
    Grossmann, M.
    Konig, S.
    Mayor, A.
    Meer, D.
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2019, 66 (07) : 1273 - 1279
  • [35] A beam angle optimization technique for proton pencil beam scanning treatment planning of lower pelvis targets
    Kiely, J. Blanco
    White, B. M.
    Both, S.
    [J]. WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, 2015, VOLS 1 AND 2, 2015, 51 : 479 - 482
  • [36] Dosimetry and Dose Rate Evaluation of Transmission Proton Pencil Beam Scanning FLASH Treatment Planning for Hypofractionated Lung Cases: A Comparison Study with Intensity Modulated Proton Therapy
    Wei, S.
    [J]. MEDICAL PHYSICS, 2021, 48 (06)
  • [37] A comparison of the dose distributions from three proton treatment planning systems in the planning of meningioma patients with single-field uniform dose pencil beam scanning
    Doolan, Paul J.
    Alshaikhi, Jailan
    Rosenberg, Ivan
    Ainsley, Christopher G.
    Gibson, Adam
    D'Souza, Derek
    Bentefour, El Hassane
    Royle, Gary
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2015, 16 (01): : 86 - 99
  • [38] Experimental Validation of the Monte Carlo Model of HYPERSCAN™ Pencil Beam Scanning System for Proton Beam Imaging and Radiation Treatment
    Huo, W.
    Zwart, T.
    Finley, C.
    Jee, K.
    Sharp, G.
    Rosenthal, S.
    Xu, X.
    Lu, H.
    [J]. MEDICAL PHYSICS, 2017, 44 (06) : 2872 - 2872
  • [39] Searching for Practical Monte Carlo Dose Calculation Parameters of Line-Scanning Proton Beam Therapy in a Commercial Treatment Planning System
    Kim, H.
    Chung, K.
    Han, Y.
    Park, W.
    Park, H.
    Lim, D.
    Choi, D.
    [J]. MEDICAL PHYSICS, 2022, 49 (06) : E872 - E873
  • [40] Pencil Beam Scanning Proton Treatment Planning for Breast Cancer Patients with Metal Tissue Expander