Dosimetry and Dose Rate Evaluation of Transmission Proton Pencil Beam Scanning FLASH Treatment Planning for Hypofractionated Lung Cases: A Comparison Study with Intensity Modulated Proton Therapy

被引:0
|
作者
Wei, S. [1 ]
机构
[1] New York Proton Ctr, East Setauket, NY USA
关键词
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PO-GePV-T-
引用
收藏
页数:1
相关论文
共 50 条
  • [1] Pencil Beam Dose Algorithm for Intensity Modulated Proton Therapy with Scanning Proton Beams
    Wang, H.
    Zheng, H.
    Cao, R.
    Jia, J.
    Song, J.
    He, T.
    Wu, Y.
    [J]. MEDICAL PHYSICS, 2017, 44 (06)
  • [2] Use of single-energy proton pencil beam scanning Bragg peak for intensity-modulated proton therapy FLASH treatment planning in liver-hypofractionated radiation therapy
    Wei, Shouyi
    Lin, Haibo
    Shi, Chengyu
    Xiong, Weijun
    Chen, Chin-Cheng
    Huang, Sheng
    Press, Robert H.
    Hasan, Shaakir
    Chhabra, Arpit M.
    Choi, J. Isabelle
    Simone, Charles B., II
    Kang, Minglei
    [J]. MEDICAL PHYSICS, 2022, 49 (10) : 6560 - 6574
  • [3] Definition of dose rate for FLASH pencil-beam scanning proton therapy: A comparative study
    Deffet, Sylvain
    Hamaide, Valentin
    Sterpin, Edmond
    [J]. MEDICAL PHYSICS, 2023, 50 (09) : 5784 - 5792
  • [4] A comparison of two pencil beam scanning treatment planning systems for proton therapy
    Langner, Ulrich W.
    Mundis, Michelle
    Strauss, Dan
    Zhu, Mingyao
    Mossahebi, Sina
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2018, 19 (01): : 156 - 163
  • [5] Time-resolved dose rate measurements in pencil beam scanning proton FLASH therapy
    Kanouta, E.
    Poulsen, P.
    Kertzscher, G.
    Sitarz, M.
    Sorensen, B.
    Johansen, J.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2022, 170 : S240 - S242
  • [6] FLASH dose rate calculation based on log files in proton pencil beam scanning therapy
    Jeon, Chanil
    Ahn, Sunghwan
    Amano, Daizo
    Kamiguchi, Nagaaki
    Cho, Sungkoo
    Sheen, Heesoon
    Park, Hee Chul
    Han, Youngyih
    [J]. MEDICAL PHYSICS, 2023, 50 (11) : 7154 - 7166
  • [7] Evaluation of a Pencil Beam Scanning Proton Dose Model for a Commercial Treatment Planning System
    Patel, D.
    Poenisch, F.
    Sahoo, N.
    Zhu, X.
    Gillin, M.
    Janson, M.
    Mohan, R.
    Titt, U.
    [J]. MEDICAL PHYSICS, 2018, 45 (06) : E261 - E261
  • [8] Simultaneous dose and dose rate optimization (SDDRO) of the FLASH effect for pencil-beam-scanning proton therapy
    Gao, Hao
    Liu, Jiulong
    Lin, Yuting
    Gan, Gregory N
    Pratx, Guillem
    Wang, Fen
    Langen, Katja
    Bradley, Jeffrey D
    Rotondo, Ronny L
    Li, Harold H
    Chen, Ronald C
    [J]. Medical Physics, 2022, 49 (03): : 2014 - 2025
  • [9] Simultaneous dose and dose rate optimization (SDDRO) of the FLASH effect for pencil-beam-scanning proton therapy
    Gao, Hao
    Liu, Jiulong
    Lin, Yuting
    Gan, Gregory N.
    Pratx, Guillem
    Wang, Fen
    Langen, Katja
    Bradley, Jeffrey D.
    Rotondo, Ronny L.
    Li, Harold H.
    Chen, Ronald C.
    [J]. MEDICAL PHYSICS, 2022, 49 (03) : 2014 - 2025
  • [10] Dosimetric Impact of Dose Rate Fall-Off in FLASH Proton Pencil Beam Scanning Treatment
    Bentefour, E. H.
    Sawant, A.
    Mossahebi, S.