Development and Evaluation of a Pixel Detector System for Pencil Beam Scanning Proton Therapy

被引:3
|
作者
Eichin, Michael [1 ]
Actis, O. [1 ]
Grossmann, M. [1 ]
Konig, S. [1 ]
Mayor, A. [1 ]
Meer, D. [1 ]
机构
[1] Paul Scherrer Inst, CH-5232 Villigen, Switzerland
关键词
Biomedical applications of radiation; field-programmable gate arrays (FPGAs); position sensitive particle detector; printed circuits; PERFORMANCE; DOSIMETRY;
D O I
10.1109/TNS.2019.2918635
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
At the Paul Scherrer Institute (PSI) in Switzerland, cancer patients are treated with protons. The PSI Gantries work with Pencil Beam Scanning (PBS) technology. For beam profile characterization, a new 2-D planar pixel detector based on Printed Circuit Board technology was developed. The main challenge of the design was the limited amount of 256 readout channels while several thousands of detector signals had to be processed. With PBS, only a few pixels will be hit by the proton beam and give a significant signal, while most of them will not capture any signal. On the detector design, the active area was divided into pixel arrays with equal size, while one array is such big to cover the whole size of the proton beam. By a so-called channel recycling technique, the same pixel number of all pixel arrays were connected together to one readout channel. The proof of concept was verified with a small detector. In the next step, the design was changed such, getting a full-scale detector for Gantry 2. The readout electronics board itself is also a development performed at PSI. A core component of the design is the ADAS1128 chip from ANALOG Devices featuring 128 input channels. The pixel detector is fully integrated into the therapy control system (TCS) through readout electronics with a field-programmable gate array (FPGA) technology. The FPGA technology allows to readout the detector synchronized to the beam delivery. This paper summarizes the features of the pixel detector design, the readout electronics, and shows the first experimental results.
引用
收藏
页码:1273 / 1279
页数:7
相关论文
共 50 条
  • [1] Applications of a novel detector for pencil beam scanning proton therapy beam quality assurance
    Yang, Pei-Ying
    Hsieh, Yang-Wei
    Kang, Chen-Lin
    Tseng, Chin-Dar
    Lin, Chih-Hsueh
    Shieh, Chin-Shiuh
    Chao, Pei-Ju
    Lee, Tsair-Fwu
    [J]. INTERNATIONAL JOURNAL OF MODERN PHYSICS B, 2021, 35 (14N16):
  • [2] Introduction to Pencil Beam Scanning Proton Therapy
    Zhu, M.
    Mossahebi, S.
    [J]. MEDICAL PHYSICS, 2020, 47 (06) : E275 - E276
  • [3] Dynamic Collimation System Controller for Pencil Beam Scanning Proton Therapy
    Patwardhan, K.
    Geoghegan, T.
    Flynn, R.
    Wang, D.
    Hyer, D.
    [J]. MEDICAL PHYSICS, 2019, 46 (06) : E97 - E97
  • [4] Neutron Dose Equivalent Evaluation for Pencil Beam Scanning Proton Therapy with Apertures
    Geng, C.
    Schuemann, J.
    Moteabbed, M.
    Paganetti, H.
    [J]. MEDICAL PHYSICS, 2015, 42 (06) : 3466 - 3466
  • [5] Pencil Beam Scanning:: a dynamical approach to proton therapy
    Sepulchre, R
    Gérard, M
    Marchand, B
    Prieels, D
    Bauvir, B
    [J]. IEEE INTERNATIONAL SYMPOSIUM ON BIO-INFORMATICS AND BIOMEDICAL ENGINEERING, PROCEEDINGS, 2000, : 370 - 375
  • [6] Evaluation of the ray-casting analytical algorithm for pencil beam scanning proton therapy
    Winterhalter, Carla
    Zepter, Stefan
    Shim, Sojin
    Meier, Gabriel
    Bolsi, Alessandra
    Fredh, Anna
    Hrbacek, Jan
    Oxley, David
    Zhang, Ye
    Weber, Damien C.
    Lomax, Antony
    Safai, Sairos
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (06):
  • [7] Development and Validation of a TOPAS Monte Carlo Model of a Dynamic Collimation System for Pencil Beam Scanning Proton Therapy
    Nelson, N.
    Culberson, W.
    Hyer, D.
    Geoghegan, T.
    Patwardhan, K.
    Smith, B.
    Flynn, R.
    Yu, J.
    Rana, S.
    Gutierrez, A.
    Hill, P.
    [J]. MEDICAL PHYSICS, 2021, 48 (06)
  • [8] Determination of surface dose in pencil beam scanning proton therapy
    Kern, A.
    Baeumer, C.
    Kroeninger, K.
    Mertens, L.
    Timmermann, B.
    Walbersloh, J.
    Wulff, J.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2019, 133 : S483 - S483
  • [9] Pencil beam scanning proton therapy for pediatric intracranial ependymoma
    Ares, Carmen
    Albertini, Francesca
    Frei-Welte, Martina
    Bolsi, Alessandra
    Grotzer, Michael A.
    Goitein, Gudrun
    Weber, Damien C.
    [J]. JOURNAL OF NEURO-ONCOLOGY, 2016, 128 (01) : 137 - 145
  • [10] Proton Pencil Beam Scanning for Rectal Cancer Radiation Therapy
    Kiely, J. P. Blanco
    White, B. M.
    Plastaras, J. P.
    Ben-Josef, E.
    Varman, C.
    Tang, S.
    Tochner, Z. A.
    Metz, J. M.
    Both, S.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2015, 93 (03): : E159 - E159