Effects of Implantable Collamer Lens V4c Placement on Iridocorneal Angle Measurements by Fourier-Domain Optical Coherence Tomography

被引:35
|
作者
Fernandez-Vigo, Jose Ignacio [1 ,3 ]
Macarro-Merino, Ana [3 ]
Fernandez-Vigo, Cristina [3 ]
Fernandez-Vigo, Jose Angel [3 ,4 ]
Martinez-De-La-Casa, Jose Maria [1 ]
Fernandez-Perez, Cristina [2 ]
Garcia-Feijoo, Julian [1 ]
机构
[1] Clin San Carlos Univ Hosp, Inst Invest Sanitaria San Carlos IdISSC, Dept Ophthalmol, Madrid, Spain
[2] Clin San Carlos Univ Hosp, Inst Invest Sanitaria San Carlos IdISSC, Dept Prevent Med, Madrid, Spain
[3] Ctr Int Oftalmol Avanzada, C Zurbano 71, Madrid 28010, Spain
[4] Univ Extremadura, Dept Ophthalmol, Badajoz, Spain
关键词
PHAKIC INTRAOCULAR-LENS; ANTERIOR-CHAMBER DEPTH; 3-YEAR FOLLOW-UP; HIGH MYOPIA; ULTRASOUND BIOMICROSCOPY; CATARACT DEVELOPMENT; ICL IMPLANTATION; CENTRAL VAULT; IRIDOTOMY; EYES;
D O I
10.1016/j.ajo.2015.11.010
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To assess by Fourier-domain optical coherence tomography (FDOCT) changes produced in iridocorneal angle measurements in patients undergoing Visian Implantable Collamer Lens (ICL) V4c (STAAR Surgical AG) placement. DESIGN: Prospective interventional case series. METHODS: In 50 eyes of 25 myopic subjects consecutively scheduled for ICL implant, FDOCT (RTVue; Optovue Inc) iridocorneal angle measurements were made before and 1 and 3,months after surgery. Trabecular-iris angle (TIA) and angle opening distance 500 mu m anterior to the scleral spur (A0D500) were compared among the quadrants nasal, temporal, and inferior, and correlations with ocular variables including lens vault were examined. RESULTS: Preoperative TIA was 48.7 +/- 8.7, 48.2 +/- 8.7, and 48.7 +/- 9.3 degrees for the nasal, temporal, and inferior quadrants, with no differences (P = 1.000). Following ICL implant, corresponding values fell to 31.2 +/- 11.5, 30.0 +/- 10.7, and 29.7 +/- 8.1 degrees at 1 month postsurgery, indicating angle narrowing of 34%-42%, and to 30.6 +/- 12.3, 30.1 +/- 11.9, and 29.8 +/- 12.3 degrees, respectively, at 3 months postsurgery. Angle measurements failed to vary between 1 month and 3 months postsurgery (P = .481). In 8 eyes, iridotrabecular contact attributable to surgery was observed. One month after surgery, vault measurements correlated with TIA (R = .309; P = .048). Six variables were identified as predictors of TIA at 1 month postsurgery (R-2 = .907). CONCLUSIONS: Although considerable angle narrowing was detected 1 month after ICL V4c implant, this narrowing remained stable at 3 months postsurgery. Factors predictive of TIA could serve to identify suitable candidates for ICL placement. (C) 2016 by Elsevier Inc. All rights reserved.
引用
收藏
页码:43 / 52
页数:10
相关论文
共 50 条
  • [31] MACULAR THICKNESS MEASUREMENTS IN NORMAL EYES WITH TIME-DOMAIN AND FOURIER-DOMAIN OPTICAL COHERENCE TOMOGRAPHY
    Huang, Jingjing
    Liu, Xing
    Wu, Ziqiang
    Xiao, Hui
    Dustin, Laurie
    Sadda, Srinivas
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2009, 29 (07): : 980 - 987
  • [32] Long-Term Evaluation of Central and Peripheral Lens Densities Post Implantation of Implantable Collamer Lens V4c
    Lin, I. -Chun
    Jiang, Yinjie
    Cheng, Mingrui
    Li, Boliang
    Lei, Yadi
    Xu, Guanghan
    Li, Mingwei
    Mao, Zhiwei
    Rui, Ning
    Chen, Xun
    Wang, Xiaoying
    CLINICAL OPHTHALMOLOGY, 2025, 19 : 733 - 745
  • [33] Rotational Stability and Outcomes of V4c Toric Implantable Collamer Lenses Placed at Different Lens Orientations
    Yang, Yukun
    Zhu, Fengjiao
    Ma, Yiping
    Li, Jing
    Li, Xiaoxi
    Yao, Xiaoming
    JOURNAL OF REFRACTIVE SURGERY, 2025, 41 (01) : e29 - e38
  • [34] The effect of implantable collamer Lens V4c on ocular biometric measurements and intraocular lens power calculation based on Pentacam-AXL and IOLMaster 500
    Di Zhang
    Meng Yang
    Ziyuan Liu
    Hongyuan Cai
    Xiaoyong Chen
    Chun Zhang
    BMC Ophthalmology, 22
  • [35] Comparison of a new implantable collamer lens formula to standards formulas using spectral domain optical coherence tomography
    Eldanasoury, Alaa
    Bains, Harkaran
    Pieger, Stefan
    INTERNATIONAL OPHTHALMOLOGY, 2023, 43 (12) : 4613 - 4620
  • [36] Comparison of a new implantable collamer lens formula to standards formulas using spectral domain optical coherence tomography
    Alaa Eldanasoury
    Harkaran Bains
    Stefan Pieger
    International Ophthalmology, 2023, 43 : 4613 - 4620
  • [37] Comparison of Implantable Collamer Lens Visian ICL V4 and ICL V4c for high myopia A cohort study
    Tian, Ying
    Jiang, Hai-Bo
    Jiang, Jian
    Wen, Dan
    Xia, Xiao-Bo
    Song, Wei-Tao
    MEDICINE, 2017, 96 (25)
  • [38] The effect of implantable collamer Lens V4c on ocular biometric measurements and intraocular lens power calculation based on Pentacam-AXL and IOLMaster 500
    Zhang, Di
    Yang, Meng
    Liu, Ziyuan
    Cai, Hongyuan
    Chen, Xiaoyong
    Zhang, Chun
    BMC OPHTHALMOLOGY, 2022, 22 (01)
  • [39] Agreement between optical coherence and Scheimpflug tomography: Vault measurements and reproducibility after implantable collamer lens implantation
    Almorin-Fernandez-Vigo, I.
    Sanchez-Guillen, I.
    Fernandez-Vigo, J. I.
    De-Pablo-Gomez-De-Liano, L.
    Kudsieh, B.
    Fernandez-Vigo, J. A.
    Macarro-Merino, A.
    JOURNAL FRANCAIS D OPHTALMOLOGIE, 2021, 44 (09): : 1370 - 1380
  • [40] Dispersion, spot size and speckle noise effects in fourier-domain optical coherence tomography
    Al-Saeed, Tarek A.
    OPTIK, 2020, 206 (206):