MACULAR THICKNESS MEASUREMENTS IN NORMAL EYES WITH TIME-DOMAIN AND FOURIER-DOMAIN OPTICAL COHERENCE TOMOGRAPHY

被引:72
|
作者
Huang, Jingjing [1 ]
Liu, Xing [1 ]
Wu, Ziqiang [2 ]
Xiao, Hui [1 ]
Dustin, Laurie [3 ]
Sadda, Srinivas [4 ]
机构
[1] Sun Yat Sen Univ, State Key Lab Ophthalmol, Zhongshan Ophthalm Ctr, Guangzhou 510060, Guangdong, Peoples R China
[2] Ctr Adv Eye Care, Carson City, NV USA
[3] Univ So Calif, Keck Sch Med, Dept Prevent Med, Los Angeles, CA 90033 USA
[4] Doheny Eye Inst, Doheny Image Reading Ctr, Los Angeles, CA 90033 USA
基金
美国国家卫生研究院;
关键词
Fourier domain; macular thickness; optical coherence tomography; time domain; FIBER LAYER THICKNESS; ULTRAHIGH-RESOLUTION; RETINAL THICKNESS; HISTOLOGIC CORRELATION; HEALTHY; REPRODUCIBILITY;
D O I
10.1097/IAE.0b013e3181a2c1a7
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To compare macular thickness measurements using time-domain optical coherence tomography (OCT) and Fourier-domain OCT. Methods: Thirty-two eyes from 32 normal patients underwent complete ophthalmic evaluation. Macular scanning using the StratusOCT and the RTVue-100 OCT were performed for a total of three times each on the same visit. The average retinal thicknesses of the nine macular sectors as defined by the Early Treatment Diabetic Retinopathy Study, along with the foveal center point and macular volume, were recorded. The SD, the coefficient of variation, and the intraclass correlation coefficient were calculated for each parameter studied. Comparisons were made between the two OCTs in terms of retinal thicknesses measurements, their reproducibility, and macular regional differences. Correlations between retinal thickness and demographic variables (age and gender) were also investigated. Due to known differences in segmentation algorithms of the two OCTs, software calipers were used to measure the distance from the internal limiting membrane to the photoreceptor inner segment-outer segment junction at the foveal center point on all RTVue scans to allow a more fair comparison. Results: The RTVue yielded greater retinal thickness measurements in nearly all macular subfields compared with the StratusOCT. Even after accounting for differences in segmentation algorithms, significant disparities were still evident with the RTVue measurements less than those of the StratusOCT at the foveal center. On both machines, the macula was thinnest at the fovea and thickest within the 3 mm ring. There were some consistent regional variations in macular thickness evident on both OCTs. Compared with the StratusOCT, the RTVue generally had lower coefficients of variation and higher intraclass coefficients, suggesting better reproducibility. Age and gender also appeared to be important determinants in some macular thickness parameters. Conclusion: Compared with StratusOCT, the RTVue fourier-domain OCT yields greater retinal thickness measurements with greater reproducibility, presumably due to different segmentation algorithms, increased sampling density, and greater resolution. However, regional differences across the macula can be consistently observed with both devices.
引用
收藏
页码:980 / 987
页数:8
相关论文
共 50 条
  • [1] Time-domain interpolation for Fourier-domain optical coherence tomography
    Zhang, Yudong
    Li, Xiqi
    Wei, Ling
    Wang, Kai
    Ding, Zhihua
    Shi, Guohua
    [J]. OPTICS LETTERS, 2009, 34 (12) : 1849 - 1851
  • [2] Macular thickness of Chinese with fourier-domain optical coherence tomography
    Yu Weihong
    Zheng Lin
    Dai Rongping
    Zhang Zhiqiao
    Dong Fangtian
    [J]. ACTA OPHTHALMOLOGICA, 2011, 89 (01) : E104 - E105
  • [3] Spectral- and time-domain optical coherence tomography measurements of macular thickness in normal eyes and in eyes with diabetic macular edema
    M A Ibrahim
    Y J Sepah
    R C A Symons
    R Channa
    E Hatef
    A Khwaja
    M Bittencourt
    J Heo
    D V Do
    Q D Nguyen
    [J]. Eye, 2012, 26 : 454 - 462
  • [4] Spectral- and time-domain optical coherence tomography measurements of macular thickness in normal eyes and in eyes with diabetic macular edema
    Ibrahim, M. A.
    Sepah, Y. J.
    Symons, R. C. A.
    Channa, R.
    Hatef, E.
    Khwaja, A.
    Bittencourt, M.
    Heo, J.
    Do, D. V.
    Nguyen, Q. D.
    [J]. EYE, 2012, 26 (03) : 454 - 462
  • [5] Deconvolution techniques in time-domain and Fourier-Domain optical coherence tomography
    Levesque, D.
    Vergnole, S.
    Dufour, M. L.
    Gauthier, B.
    Lamouche, G.
    [J]. REVIEW OF PROGRESS IN QUANTITATIVE NONDESTRUCTIVE EVALUATION, VOL 27A AND 27B, 2008, 975 : 563 - 570
  • [6] Comparison of the Optic Nerve Imaging by Time-Domain Optical Coherence Tomography and Fourier-Domain Optical Coherence Tomography in Distinguishing Normal Eyes From Those With Glaucoma
    Kim, Na Rae
    Kim, Ji Hyun
    Kim, Chan Yun
    Jun, Ikhyun
    Seong, Gong Je
    Lee, Eun Suk
    [J]. JOURNAL OF GLAUCOMA, 2013, 22 (01) : 36 - 43
  • [7] Corneal Epithelial Thickness Mapping in Normal and Keratoconic Eyes With Fourier-Domain Optical Coherence Tomography
    Li, Y.
    Tan, O.
    Huang, D.
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [8] Corneal Epithelial Thickness Mapping by Fourier-Domain Optical Coherence Tomography in Normal and Keratoconic Eyes
    Li, Yan
    Tan, Ou
    Brass, Robert
    Weiss, Jack L.
    Huang, David
    [J]. OPHTHALMOLOGY, 2012, 119 (12) : 2425 - 2433
  • [9] Comparison of Fourier-Domain and Time-Domain Optical Coherence Tomography in the Measurement of Thinnest Corneal Thickness in Keratoconus
    Wang, Chunxiao
    Xia, Xueying
    Tian, Bishan
    Zhou, Shiyou
    [J]. JOURNAL OF OPHTHALMOLOGY, 2015, 2015
  • [10] Comparison of Fourier-Domain and Time-Domain Optical Coherence Tomography for Assessment of Corneal Thickness and Intersession Repeatability
    Prakash, Gaurav
    Agarwal, Amar
    Jacob, Soosan
    Kumar, Dhivya Ashok
    Agarwal, Athiya
    Banerjee, Rumki
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 2009, 148 (02) : 282 - 290