Effects of Implantable Collamer Lens V4c Placement on Iridocorneal Angle Measurements by Fourier-Domain Optical Coherence Tomography

被引:35
|
作者
Fernandez-Vigo, Jose Ignacio [1 ,3 ]
Macarro-Merino, Ana [3 ]
Fernandez-Vigo, Cristina [3 ]
Fernandez-Vigo, Jose Angel [3 ,4 ]
Martinez-De-La-Casa, Jose Maria [1 ]
Fernandez-Perez, Cristina [2 ]
Garcia-Feijoo, Julian [1 ]
机构
[1] Clin San Carlos Univ Hosp, Inst Invest Sanitaria San Carlos IdISSC, Dept Ophthalmol, Madrid, Spain
[2] Clin San Carlos Univ Hosp, Inst Invest Sanitaria San Carlos IdISSC, Dept Prevent Med, Madrid, Spain
[3] Ctr Int Oftalmol Avanzada, C Zurbano 71, Madrid 28010, Spain
[4] Univ Extremadura, Dept Ophthalmol, Badajoz, Spain
关键词
PHAKIC INTRAOCULAR-LENS; ANTERIOR-CHAMBER DEPTH; 3-YEAR FOLLOW-UP; HIGH MYOPIA; ULTRASOUND BIOMICROSCOPY; CATARACT DEVELOPMENT; ICL IMPLANTATION; CENTRAL VAULT; IRIDOTOMY; EYES;
D O I
10.1016/j.ajo.2015.11.010
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To assess by Fourier-domain optical coherence tomography (FDOCT) changes produced in iridocorneal angle measurements in patients undergoing Visian Implantable Collamer Lens (ICL) V4c (STAAR Surgical AG) placement. DESIGN: Prospective interventional case series. METHODS: In 50 eyes of 25 myopic subjects consecutively scheduled for ICL implant, FDOCT (RTVue; Optovue Inc) iridocorneal angle measurements were made before and 1 and 3,months after surgery. Trabecular-iris angle (TIA) and angle opening distance 500 mu m anterior to the scleral spur (A0D500) were compared among the quadrants nasal, temporal, and inferior, and correlations with ocular variables including lens vault were examined. RESULTS: Preoperative TIA was 48.7 +/- 8.7, 48.2 +/- 8.7, and 48.7 +/- 9.3 degrees for the nasal, temporal, and inferior quadrants, with no differences (P = 1.000). Following ICL implant, corresponding values fell to 31.2 +/- 11.5, 30.0 +/- 10.7, and 29.7 +/- 8.1 degrees at 1 month postsurgery, indicating angle narrowing of 34%-42%, and to 30.6 +/- 12.3, 30.1 +/- 11.9, and 29.8 +/- 12.3 degrees, respectively, at 3 months postsurgery. Angle measurements failed to vary between 1 month and 3 months postsurgery (P = .481). In 8 eyes, iridotrabecular contact attributable to surgery was observed. One month after surgery, vault measurements correlated with TIA (R = .309; P = .048). Six variables were identified as predictors of TIA at 1 month postsurgery (R-2 = .907). CONCLUSIONS: Although considerable angle narrowing was detected 1 month after ICL V4c implant, this narrowing remained stable at 3 months postsurgery. Factors predictive of TIA could serve to identify suitable candidates for ICL placement. (C) 2016 by Elsevier Inc. All rights reserved.
引用
收藏
页码:43 / 52
页数:10
相关论文
共 50 条
  • [21] Endothelial cell loss post-implantable collamer lens V4c: meta-analysis
    Kisiel, Filip Blazej
    Gurumurthy, Gerard Jonathan
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2024, 50 (04): : 420 - 423
  • [22] Anterior Chamber Angle and Trabecular Meshwork Measurements Made by Fourier-domain Optical Coherence Tomography in Healthy White Children
    Fernandez-Vigo, Jose I.
    De-Pablo-Gomez-de-Liano, Lucia
    Fernandez-Vigo, Cristina
    Arcos-Villegas, Gabriel
    Fernandez-Perez, Cristina
    Garcia-Feijoo, Julian
    Fernandez-Vigo, Jose A.
    JOURNAL OF GLAUCOMA, 2017, 26 (09) : 810 - 815
  • [23] Fourier domain optical coherence tomography to assess the iridocorneal angle and correlation study in a large Caucasian population
    Ignacio Fernandez-Vigo, Jose
    Garcia-Feijoo, Julian
    Maria Martinez-de-la-Casa, Jose
    Garcia-Bella, Javier
    Arriola-Villalobos, Pedro
    Fernandez-Perez, Cristina
    Angel Fernandez-Vigo, Jose
    BMC OPHTHALMOLOGY, 2016, 16
  • [24] Fourier domain optical coherence tomography to assess the iridocorneal angle and correlation study in a large Caucasian population
    José Ignacio Fernández-Vigo
    Julián García-Feijóo
    José María Martínez-de-la-Casa
    Javier García-Bella
    Pedro Arriola-Villalobos
    Cristina Fernández-Pérez
    José Ángel Fernández-Vigo
    BMC Ophthalmology, 16
  • [25] Analysis of Inter-Eye Vault Differences After Implantable Collamer Lens (V4c) Implantation
    Tan, Xin
    Liu, Wenjie
    Chang, Ying
    Wu, Wanmin
    Yang, Lichun
    Liu, Jiewei
    INTERNATIONAL JOURNAL OF GENERAL MEDICINE, 2023, 16 : 2451 - 2459
  • [26] Safety and efficacy of toric implantable collamer lens V4c model - A retrospective South Indian study
    Chaitanya, S. Ravi
    Anitha, Venugopal
    Ravindran, Meenakshi
    Ghorpade, Aditya
    Rengappa, Ramakrishnan
    Uduman, Mahammed Sithiq
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2020, 68 (12) : 3006 - 3011
  • [27] A four-year observation of corneal densitometry after implantable collamer lens V4c implantation
    Zhao, Jing
    Yang, Wen
    Zhao, Jiao
    Shen, Yang
    Sun, Ling
    Han, Tian
    Wang, Xiaoying
    Yao, Peijun
    Zhou, Xingtao
    ANNALS OF TRANSLATIONAL MEDICINE, 2021, 9 (07)
  • [28] Visual outcomes and corneal biomechanics after V4c implantable collamer lens implantation in subclinical keratoconus
    Li, Kangjun
    Wang, Zheng
    Zhang, Dexiu
    Wang, Shanshan
    Song, Xiaocui
    Li, Yaxin
    Wang, Ming X.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2020, 46 (10): : 1339 - 1345
  • [29] Diagnostic capability of Fourier-Domain optical coherence tomography in early primary open angle glaucoma
    FANG Yuan PAN Yingzi LI Mei QIAO Ronghua and CAI Yu Department of Ophthalmology Peking University First Hospital Beijing China
    中华医学杂志(英文版), 2010, (15) : 2045 - 2050
  • [30] Diagnostic capability of Fourier-Domain optical coherence tomography in early primary open angle glaucoma
    Fang Yuan
    Pan Ying-zi
    Li Mei
    Qiao Rong-hua
    Cai Yu
    CHINESE MEDICAL JOURNAL, 2010, 123 (15) : 2045 - 2050