Effects of Implantable Collamer Lens V4c Placement on Iridocorneal Angle Measurements by Fourier-Domain Optical Coherence Tomography

被引:35
|
作者
Fernandez-Vigo, Jose Ignacio [1 ,3 ]
Macarro-Merino, Ana [3 ]
Fernandez-Vigo, Cristina [3 ]
Fernandez-Vigo, Jose Angel [3 ,4 ]
Martinez-De-La-Casa, Jose Maria [1 ]
Fernandez-Perez, Cristina [2 ]
Garcia-Feijoo, Julian [1 ]
机构
[1] Clin San Carlos Univ Hosp, Inst Invest Sanitaria San Carlos IdISSC, Dept Ophthalmol, Madrid, Spain
[2] Clin San Carlos Univ Hosp, Inst Invest Sanitaria San Carlos IdISSC, Dept Prevent Med, Madrid, Spain
[3] Ctr Int Oftalmol Avanzada, C Zurbano 71, Madrid 28010, Spain
[4] Univ Extremadura, Dept Ophthalmol, Badajoz, Spain
关键词
PHAKIC INTRAOCULAR-LENS; ANTERIOR-CHAMBER DEPTH; 3-YEAR FOLLOW-UP; HIGH MYOPIA; ULTRASOUND BIOMICROSCOPY; CATARACT DEVELOPMENT; ICL IMPLANTATION; CENTRAL VAULT; IRIDOTOMY; EYES;
D O I
10.1016/j.ajo.2015.11.010
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To assess by Fourier-domain optical coherence tomography (FDOCT) changes produced in iridocorneal angle measurements in patients undergoing Visian Implantable Collamer Lens (ICL) V4c (STAAR Surgical AG) placement. DESIGN: Prospective interventional case series. METHODS: In 50 eyes of 25 myopic subjects consecutively scheduled for ICL implant, FDOCT (RTVue; Optovue Inc) iridocorneal angle measurements were made before and 1 and 3,months after surgery. Trabecular-iris angle (TIA) and angle opening distance 500 mu m anterior to the scleral spur (A0D500) were compared among the quadrants nasal, temporal, and inferior, and correlations with ocular variables including lens vault were examined. RESULTS: Preoperative TIA was 48.7 +/- 8.7, 48.2 +/- 8.7, and 48.7 +/- 9.3 degrees for the nasal, temporal, and inferior quadrants, with no differences (P = 1.000). Following ICL implant, corresponding values fell to 31.2 +/- 11.5, 30.0 +/- 10.7, and 29.7 +/- 8.1 degrees at 1 month postsurgery, indicating angle narrowing of 34%-42%, and to 30.6 +/- 12.3, 30.1 +/- 11.9, and 29.8 +/- 12.3 degrees, respectively, at 3 months postsurgery. Angle measurements failed to vary between 1 month and 3 months postsurgery (P = .481). In 8 eyes, iridotrabecular contact attributable to surgery was observed. One month after surgery, vault measurements correlated with TIA (R = .309; P = .048). Six variables were identified as predictors of TIA at 1 month postsurgery (R-2 = .907). CONCLUSIONS: Although considerable angle narrowing was detected 1 month after ICL V4c implant, this narrowing remained stable at 3 months postsurgery. Factors predictive of TIA could serve to identify suitable candidates for ICL placement. (C) 2016 by Elsevier Inc. All rights reserved.
引用
收藏
页码:43 / 52
页数:10
相关论文
共 50 条
  • [41] Anterior Chamber Angle Measurements Using Schwalbe's Line With High-resolution Fourier-Domain Optical Coherence Tomography
    Qin, Bing
    Francis, Brian A.
    Li, Yan
    Tang, Maolong
    Zhang, Xinbo
    Jiang, Chunhui
    Cleary, Catherine
    Huang, David
    JOURNAL OF GLAUCOMA, 2013, 22 (09) : 684 - 688
  • [42] Changes in anterior lens density after Implantable Collamer Lens V4c implantation: a 4-year prospective observational study
    Yang, Wen
    Zhao, Jing
    Zhao, Jiao
    Shen, Yang
    Niu, Lingling
    Ruma, A.
    Wang, Xiaoying
    Zhou, Xingtao
    ACTA OPHTHALMOLOGICA, 2021, 99 (03) : 326 - 333
  • [43] Refractive outcomes and optical quality after implantation of posterior chamber phakic implantable collamer lens with a central hole (ICL V4c)
    Huamao Miao
    Xun Chen
    Mi Tian
    Yingjun Chen
    Xiaoying Wang
    Xingtao Zhou
    BMC Ophthalmology, 18
  • [44] Refractive outcomes and optical quality after implantation of posterior chamber phakic implantable collamer lens with a central hole (ICL V4c)
    Miao, Huamao
    Chen, Xun
    Tian, Mi
    Chen, Yingjun
    Wang, Xiaoying
    Zhou, Xingtao
    BMC OPHTHALMOLOGY, 2018, 18
  • [45] Optical quality after posterior chamber Phakic implantation of an intraocular Lens with a central hole (V4c implantable Collamer Lens) under different lighting conditions
    He, Tianrui
    Zhu, Yi
    Zhou, Jibo
    BMC OPHTHALMOLOGY, 2020, 20 (01)
  • [46] Comparison of visual outcomes after non-toric and toric implantable collamer lens V4c for myopia and astigmatism
    Wei, Ruoyan
    Li, Meiyan
    Niu, Lingling
    Aruma, Aruma
    Miao, Huamao
    Shen, Yang
    Yao, Peijun
    Wang, Xiaoying
    Zhang, Huihui
    Zhou, Xingtao
    ACTA OPHTHALMOLOGICA, 2021, 99 (05) : 511 - 518
  • [47] Consistency of corneal sublayer thickness measurements using Fourier-domain optical coherence tomography after phacoemulsification
    Lopez-Miguel, Alberto
    Calabuig-Goena, Maria
    Marques-Fernandez, Victoria
    Fernandez, Itziar
    Alio, Jorge L.
    Maldonado, Miguel J.
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2016, 26 (06) : 540 - 545
  • [48] Optical quality after posterior chamber Phakic implantation of an intraocular Lens with a central hole (V4c implantable Collamer Lens) under different lighting conditions
    Tianrui He
    Yi Zhu
    Jibo Zhou
    BMC Ophthalmology, 20
  • [49] Changes of dysfunctional lens index before and after implantable collamer lens V4c implantation in patients with moderate-to-high myopia
    Cao, Weifang
    Zhang, Suhua
    Liu, Qian
    Zhou, Jing
    Yuan, Xiaoyong
    INTERNATIONAL OPHTHALMOLOGY, 2023, 43 (11) : 4111 - 4120
  • [50] Polar value analysis of astigmatic change and rotational stability after implantation of V4c toric implantable collamer lens
    Nie, Danyao
    Yan, Pisong
    Yan, Zonghui
    Zhang, Jing
    He, Wenling
    Li, Ming
    Sun, Liangnan
    Huang, Mingquan
    Liu, Xinhua
    Lin, Haotian
    ANNALS OF TRANSLATIONAL MEDICINE, 2021, 9 (02)