Quantitative Assessment of Inflow Malposition in Two Continuous-Flow Left Ventricular Assist Devices

被引:23
|
作者
Sorensen, Erik N. [1 ]
Kon, Zachary N.
Feller, Erika D.
Pham, Si M.
Griffith, Bartley P.
机构
[1] Univ Maryland, Med Ctr, Dept Clin Engn, 22 S Greene St,Rm PTH06, Baltimore, MD 21201 USA
来源
ANNALS OF THORACIC SURGERY | 2018年 / 105卷 / 05期
关键词
PUMP; THROMBOSIS; IMPLANTATION; OPTIMIZATION; MIGRATION; SUPPORT; CANNULA;
D O I
10.1016/j.athoracsur.2017.12.004
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. We previously investigated preoperative variables associated with qualitative inflow cannula malposition in the HeartMate II (Thoratec-Abbott, Abbott Park, IL) continuous-flow left ventricular assist device. In this report, we assess inflow cannula malposition quantitatively in recipients of both the HeartMate II and the HeartWare (Medtronic-HeartWare, Minneapolis, MN) and examine its association with device thrombosis. Methods. Malposition was quantified based on angular deviation from a hypothetic ideal inflow cannula position in two orthogonal computed tomography imaging planes. Ideal position lies on a line from the apex to the center of the mitral valve. Positive anterior plane angulation indicates deviation toward the superior free wall; negative, toward the inferior wall. Positive lateral plane angulation indicates deviation toward the septum; negative, toward the lateral wall. Device thrombosis was assessed based on clinical criteria. Results. Fifty-four HeartMate II patients and 68 HeartWare patients were analyzed. Inflow cannula deviation was significantly higher for HeartMate II than for HeartWare (anterior plane angle 36.7 +/- 16.8 versus -18.7 +/- 11.6 degrees, p < 0.001; lateral plane angle 23.7 +/- 20.1 versus 0.2 +/- 15.0 degrees, p < 0.001. Pump thrombosis occurred in 31% of HeartMate II patients and 2.9% of HeartWare patients (p < 0.001). In a multivariate model, HeartMate II and increasing inflow cannula deviation toward the septum were associated with higher thrombosis risk (odds ratio 1.35 per 10-degree increase). Conclusions. We found distinct device-dependent differences in inflow cannula positioning and thrombosis, with HeartWare showing both less malposition and less thrombosis. Malposition toward the ventricular septum may contribute to pump thrombosis through a vicious cycle of suction events, low flow, and speed reduction. (C) 2018 by The Society of Thoracic Surgeons.
引用
收藏
页码:1377 / 1383
页数:7
相关论文
共 50 条
  • [31] Improvement in respiratory muscle dysfunction with continuous-flow left ventricular assist devices
    Dimopoulos, Stavros K.
    Drakos, Stavros G.
    Terrovitis, John V.
    Tzanis, Georgios S.
    Nanas, Serafim N.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2010, 29 (08): : 906 - 908
  • [32] Perils of bridge to transplantation in patients on continuous-flow left ventricular assist devices
    Moazami, Nader
    Reyentovich, Alex
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2019, 38 (04): : 481 - 482
  • [33] Factor Xa inhibitors in patients with continuous-flow left ventricular assist devices
    Parikh, Vishal Y.
    Parikh, Umang M.
    Moctezuma-Ramirez, Angel
    Lamba, Harveen K.
    George, Joggy K.
    Fedson, Savitri
    Nair, Ajith P.
    Frazier, O. H.
    Delgado, Reynolds M.
    GENERAL THORACIC AND CARDIOVASCULAR SURGERY, 2020, 68 (11) : 1278 - 1284
  • [34] Allograft Rejection in Patients Supported With Continuous-Flow Left Ventricular Assist Devices
    Healy, Aaron H.
    Mason, Nathan O.
    Hammond, M. Elizabeth
    Reid, Bruce B.
    Clayson, Stephen E.
    Drakos, Stavros G.
    Kfoury, Abdallah G.
    Patel, Amit N.
    Bull, David A.
    Budge, Deborah
    Alharethi, Rami A.
    Bader, Feras M.
    Gilbert, Edward M.
    Stehlik, Josef
    Selzman, Craig H.
    ANNALS OF THORACIC SURGERY, 2011, 92 (05): : 1601 - 1607
  • [35] Prevalence of Cerebral Microbleeds in Patients With Continuous-Flow Left Ventricular Assist Devices
    Yoshioka, Daisuke
    Okazaki, Shuhei
    Toda, Koichi
    Murase, Sho
    Saito, Shunsuke
    Domae, Keitaro
    Miyagawa, Shigeru
    Yoshikawa, Yasushi
    Daimon, Takashi
    Sakaguchi, Manabu
    Sawa, Yoshiki
    JOURNAL OF THE AMERICAN HEART ASSOCIATION, 2017, 6 (09):
  • [36] Blood Pressure Measurement in Patients with Continuous-Flow Left Ventricular Assist Devices
    Woldendorp, K. D.
    Gupta, S.
    Markey, P.
    Robson, D.
    Dhital, K.
    Hayward, C. S.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2013, 32 (04): : S91 - S92
  • [37] Predictors of Late Survival Following Continuous-Flow Left Ventricular Assist Devices
    Singh, S. K.
    Anand, J.
    Shah, R. M.
    Simpson, L.
    Cohn, W. E.
    Civitello, A. B.
    Mallidi, H. R.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2015, 34 (04): : S24 - S25
  • [38] Defining a Decade of Experience with Continuous-Flow Left Ventricular Assist Devices Preface
    Shah, Palak
    Cowger, Jennifer A.
    CARDIOLOGY CLINICS, 2018, 36 (04) : XIII - XIII
  • [39] Cerebrovascular events in children on intracorporeal continuous-flow left ventricular assist devices
    Sert, Dogan Emre
    Kocabeyoglu, Sinan Sabit
    Kervan, Umit
    Karahan, Mehmet
    Beyazal, Osman Fehmi
    Akdi, Mustafa
    Yilmaz, Abdulkadir
    Catav, Zeki
    ARTIFICIAL ORGANS, 2020, 44 (12) : 1251 - 1258
  • [40] Intravenous Iron Repletion in Patients With Continuous-Flow Left Ventricular Assist Devices
    Bernier, Thomas D.
    Stern, Gretchen
    Buckley, Leo F.
    Vieira, Jefferson L.
    Siddiqi, Hasan K.
    Mehra, Mandeep R.
    ASAIO JOURNAL, 2023, 69 (03) : E115 - E117