Quantitative Assessment of Inflow Malposition in Two Continuous-Flow Left Ventricular Assist Devices

被引:23
|
作者
Sorensen, Erik N. [1 ]
Kon, Zachary N.
Feller, Erika D.
Pham, Si M.
Griffith, Bartley P.
机构
[1] Univ Maryland, Med Ctr, Dept Clin Engn, 22 S Greene St,Rm PTH06, Baltimore, MD 21201 USA
来源
ANNALS OF THORACIC SURGERY | 2018年 / 105卷 / 05期
关键词
PUMP; THROMBOSIS; IMPLANTATION; OPTIMIZATION; MIGRATION; SUPPORT; CANNULA;
D O I
10.1016/j.athoracsur.2017.12.004
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. We previously investigated preoperative variables associated with qualitative inflow cannula malposition in the HeartMate II (Thoratec-Abbott, Abbott Park, IL) continuous-flow left ventricular assist device. In this report, we assess inflow cannula malposition quantitatively in recipients of both the HeartMate II and the HeartWare (Medtronic-HeartWare, Minneapolis, MN) and examine its association with device thrombosis. Methods. Malposition was quantified based on angular deviation from a hypothetic ideal inflow cannula position in two orthogonal computed tomography imaging planes. Ideal position lies on a line from the apex to the center of the mitral valve. Positive anterior plane angulation indicates deviation toward the superior free wall; negative, toward the inferior wall. Positive lateral plane angulation indicates deviation toward the septum; negative, toward the lateral wall. Device thrombosis was assessed based on clinical criteria. Results. Fifty-four HeartMate II patients and 68 HeartWare patients were analyzed. Inflow cannula deviation was significantly higher for HeartMate II than for HeartWare (anterior plane angle 36.7 +/- 16.8 versus -18.7 +/- 11.6 degrees, p < 0.001; lateral plane angle 23.7 +/- 20.1 versus 0.2 +/- 15.0 degrees, p < 0.001. Pump thrombosis occurred in 31% of HeartMate II patients and 2.9% of HeartWare patients (p < 0.001). In a multivariate model, HeartMate II and increasing inflow cannula deviation toward the septum were associated with higher thrombosis risk (odds ratio 1.35 per 10-degree increase). Conclusions. We found distinct device-dependent differences in inflow cannula positioning and thrombosis, with HeartWare showing both less malposition and less thrombosis. Malposition toward the ventricular septum may contribute to pump thrombosis through a vicious cycle of suction events, low flow, and speed reduction. (C) 2018 by The Society of Thoracic Surgeons.
引用
收藏
页码:1377 / 1383
页数:7
相关论文
共 50 条
  • [21] Echocardiography and Continuous-Flow Left Ventricular Assist Devices Evidence and Limitations
    Cohen, David G.
    Thomas, James D.
    Freed, Benjamin H.
    Rich, Jonathan D.
    Sauer, Andrew J.
    JACC-HEART FAILURE, 2015, 3 (07) : 554 - 564
  • [22] Cerebrovascular Events After Continuous-Flow Left Ventricular Assist Devices
    Tahsili-Fahadan, Pouya
    Curfman, David R.
    Davis, Albert A.
    Yahyavi-Firouz-Abadi, Noushin
    Rivera-Lara, Lucia
    Nassif, Michael E.
    LaRue, Shane J.
    Ewald, Gregory A.
    Zazulia, Allyson R.
    NEUROCRITICAL CARE, 2018, 29 (02) : 225 - 232
  • [23] COST-EFFECTIVENESS OF CONTINUOUS-FLOW LEFT VENTRICULAR ASSIST DEVICES
    Neyt, Mattias
    Van den Bruel, Ann
    Smit, Yolba
    De Jonge, Nicolaas
    Erasmus, Michiel
    Van Dijk, Diederik
    Vlayen, Joan
    INTERNATIONAL JOURNAL OF TECHNOLOGY ASSESSMENT IN HEALTH CARE, 2013, 29 (03) : 254 - 260
  • [24] Endocrine Challenges in Patients with Continuous-Flow Left Ventricular Assist Devices
    Martucci, Gennaro
    Pappalardo, Federico
    Subramanian, Harikesh
    Ingoglia, Giulia
    Conoscenti, Elena
    Arcadipane, Antonio
    NUTRIENTS, 2021, 13 (03) : 1 - 17
  • [25] Durability of continuous-flow left ventricular assist devices: a systematic review
    Xie, Ashleigh
    Phan, Kevin
    Yan, Tristan D.
    ANNALS OF CARDIOTHORACIC SURGERY, 2014, 3 (06) : 547 - 556
  • [26] Effects of pulsatile- and continuous-flow left ventricular assist devices on left ventricular unloading
    Garcia, Santiago
    Kandar, Forum
    Boyle, Andrew
    Colvin-Adams, Monica
    Lliao, Kenneth
    Joyce, Lyle
    John, Ranjit
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2008, 27 (03): : 261 - 267
  • [27] Continuous-Flow Left Ventricular Assist Device
    Landzaat, Lindy H.
    Sinclair, Christian T.
    Rosielle, Drew A.
    NEW ENGLAND JOURNAL OF MEDICINE, 2010, 362 (12): : 1149 - 1149
  • [28] The risk of right ventricular failure with current continuous-flow left ventricular assist devices
    Loforte, Antonio
    Grigioni, Francesco
    Marinelli, Giuseppe
    EXPERT REVIEW OF MEDICAL DEVICES, 2017, 14 (12) : 969 - 983
  • [29] Clinical Implications of Physiologic Flow Adjustment in Continuous-Flow Left Ventricular Assist Devices
    Tchantchaleishvili, Vakhtang
    Luc, Jesica G. Y.
    Cohan, Caitlin M.
    Phan, Kevin
    Hubbert, Laila
    Day, Steven W.
    Masey, H. Todd
    ASAIO JOURNAL, 2017, 63 (03) : 241 - 250
  • [30] Competing Risks to Transplant in Bridging With Continuous-flow Left Ventricular Assist Devices
    Bakir, Nadia H.
    Finnan, Michael J.
    Itoh, Akinobu
    Pasque, Michael K.
    Ewald, Gregory A.
    Kotkar, Kunal D.
    Damiano, Ralph J.
    Moon, Marc R.
    Hartupee, Justin C.
    Schilling, Joel D.
    Masood, Muhammad F.
    ANNALS OF THORACIC SURGERY, 2022, 114 (04): : 1276 - 1283