Quantitative Assessment of Inflow Malposition in Two Continuous-Flow Left Ventricular Assist Devices

被引:23
|
作者
Sorensen, Erik N. [1 ]
Kon, Zachary N.
Feller, Erika D.
Pham, Si M.
Griffith, Bartley P.
机构
[1] Univ Maryland, Med Ctr, Dept Clin Engn, 22 S Greene St,Rm PTH06, Baltimore, MD 21201 USA
来源
ANNALS OF THORACIC SURGERY | 2018年 / 105卷 / 05期
关键词
PUMP; THROMBOSIS; IMPLANTATION; OPTIMIZATION; MIGRATION; SUPPORT; CANNULA;
D O I
10.1016/j.athoracsur.2017.12.004
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. We previously investigated preoperative variables associated with qualitative inflow cannula malposition in the HeartMate II (Thoratec-Abbott, Abbott Park, IL) continuous-flow left ventricular assist device. In this report, we assess inflow cannula malposition quantitatively in recipients of both the HeartMate II and the HeartWare (Medtronic-HeartWare, Minneapolis, MN) and examine its association with device thrombosis. Methods. Malposition was quantified based on angular deviation from a hypothetic ideal inflow cannula position in two orthogonal computed tomography imaging planes. Ideal position lies on a line from the apex to the center of the mitral valve. Positive anterior plane angulation indicates deviation toward the superior free wall; negative, toward the inferior wall. Positive lateral plane angulation indicates deviation toward the septum; negative, toward the lateral wall. Device thrombosis was assessed based on clinical criteria. Results. Fifty-four HeartMate II patients and 68 HeartWare patients were analyzed. Inflow cannula deviation was significantly higher for HeartMate II than for HeartWare (anterior plane angle 36.7 +/- 16.8 versus -18.7 +/- 11.6 degrees, p < 0.001; lateral plane angle 23.7 +/- 20.1 versus 0.2 +/- 15.0 degrees, p < 0.001. Pump thrombosis occurred in 31% of HeartMate II patients and 2.9% of HeartWare patients (p < 0.001). In a multivariate model, HeartMate II and increasing inflow cannula deviation toward the septum were associated with higher thrombosis risk (odds ratio 1.35 per 10-degree increase). Conclusions. We found distinct device-dependent differences in inflow cannula positioning and thrombosis, with HeartWare showing both less malposition and less thrombosis. Malposition toward the ventricular septum may contribute to pump thrombosis through a vicious cycle of suction events, low flow, and speed reduction. (C) 2018 by The Society of Thoracic Surgeons.
引用
收藏
页码:1377 / 1383
页数:7
相关论文
共 50 条
  • [41] The Physiological Rationale for Incorporating Pulsatility in Continuous-Flow Left Ventricular Assist Devices
    Grosman-Rimon, Liza
    Billia, Filio
    Kobulnik, Jeremy
    Bar-Ziv, Stacey Pollock
    Cherney, David Z.
    Rao, Vivek
    CARDIOLOGY IN REVIEW, 2018, 26 (06) : 294 - 301
  • [42] Benefits of Neurohormonal Therapy in Patients With Continuous-Flow Left Ventricular Assist Devices
    Yousefzai, Rayan
    Brambatti, Michela
    Tran, Hao A.
    Pedersen, Rachel
    Braun, Oscar O.
    Baykaner, Tina
    Ghashghaei, Roxana
    Sulemanjee, Nasir Z.
    Cheema, Omar M.
    Rappelt, Matthew
    Baeza, Carmela
    Alkhayyat, Abdulaziz
    Shi, Yang
    Pretorius, Victor
    Greenberg, Barry
    Adler, Eric
    Thohan, Vinay
    ASAIO JOURNAL, 2020, 66 (04) : 409 - 414
  • [43] Hemodynamic and exercise performance with Pulsatile and continuous-flow left ventricular assist devices
    Haft, Jonathan
    Armstrong, William
    Dyke, David B.
    Aaronson, Keith D.
    Koelling, Todd M.
    Farrar, David J.
    Pagani, Francis D.
    CIRCULATION, 2007, 116 (11) : I8 - I15
  • [44] Metabolic Dysfunction in Continuous-Flow Left Ventricular Assist Devices Patients and Outcomes
    Nguyen, Ann B.
    Imamura, Teruhiko
    Besser, Stephanie
    Rodgers, Daniel
    Chung, Ben
    Raikhelkar, Jayant
    Kalantari, Sara
    Smith, Bryan
    Sarswat, Nitasha
    LaBuhn, Colleen
    Jeevanandam, Valluvan
    Kim, Gene
    Sayer, Gabriel
    Uriel, Nir
    JOURNAL OF THE AMERICAN HEART ASSOCIATION, 2019, 8 (22):
  • [45] Concomitant mitral repair and continuous-flow left ventricular assist devices: Is it warranted?
    Fukuhara, Shinichi
    Takeda, Koji
    Chiuzan, Codruta
    Han, Jiho
    Kurlansky, Paul A.
    Takayama, Hiroo
    Naka, Yoshifumi
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2017, 154 (04): : 1303 - +
  • [46] Measuring Blood Pressure in Patients with Continuous-Flow Left Ventricular Assist Devices
    Kerk, K. L.
    Truong, T. H.
    Lim, C. H.
    Tan, T. E.
    Sim, D.
    Lim, C. P.
    Sivathasan, C.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2016, 35 (04): : S340 - S340
  • [47] The Effects of Continuous-flow Left Ventricular Assist Devices on Peripheral Vascular Function
    Witman, Melissa A. H.
    Groot, H. Jonathan
    Gifford, Jayson R.
    Trinity, Joel D.
    Stehlik, Josef
    Drakos, Stavros G.
    Richardson, Russell S.
    FASEB JOURNAL, 2013, 27
  • [48] Factor Xa inhibitors in patients with continuous-flow left ventricular assist devices
    Vishal Y. Parikh
    Umang M. Parikh
    Angel Moctezuma-Ramirez
    Harveen K. Lamba
    Joggy K. George
    Savitri Fedson
    Ajith P. Nair
    O. H.  Frazier
    Reynolds M. Delgado
    General Thoracic and Cardiovascular Surgery, 2020, 68 : 1278 - 1284
  • [49] Transmission of Pulsatility Into the Brain of Patients with Continuous-Flow Left Ventricular Assist Devices
    Stohr, E. J.
    Castagna, F.
    Pinsino, A.
    Cockcroft, J. R.
    Yuzefpolskaya, M.
    Garan, A. R.
    Topkara, V. K.
    Takayama, H.
    Takeda, K.
    Naka, Y.
    Colombo, P. C.
    Willey, J. Z.
    McDonnell, B. J.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2018, 37 (04): : S284 - S284
  • [50] Non-invasive assessment of arterial pulsatility in patients with continuous-flow left ventricular assist devices
    Cross, Troy J.
    Sajgalik, Pavol
    Fabian, Vratislav
    Matera, Lukas
    Kushwaha, Sudhir S.
    Maltais, Simon
    Stulak, John M.
    Schirger, John A.
    Johnson, Bruce D.
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2020, 43 (02): : 99 - 108